      Description: HART? Temperature Transmitter with Display & Probe
      Inputs: Thermocouple, RTD, Ω & mV
      Power: Loop-Powered (10.5 to 45 VDC, reverse polarity protected)
      Display: Backlit LCD PV: 0.3" (8 mm)
      PD312型HART系列溫度變送器(帶現(xiàn)場顯示和傳感器) 產(chǎn)品信息




      I'd like to make an inquiry on this product


      FEATURES

      • Smart Temperature Transmitters
      • Universal Input: RTD, TC, Ohm & mV Inputs
      • Rugged General Purpose Models
      • 330° Rotatable Backlit LCD
      • Display PV, Input Type, Eng Units & Bargraph
      • Galvanic Isolation Prevents Ground Loops
      • Wide Voltage Range: 10.5 to 45 VDC
      • Wide Operating Temperature Range
      • Protection Heads & Thermowells Available
      • FM, CSA, ATEX, IECEx Explosion-Proof Enclosures
      • Order Factory Configured, Ready to Install*

      * Transmitters can also be compley configured using the ExSenseView PC software and modem. HART models can also be configured using a HART Communicator (with the exception of input Type and Units).

      INTRODUCTION

      The ExSense T Series is a line of rugged, smart temperature transmitters that includes models with HART communication capability. These models can be configured using a HART modem and a PC running the free HART software provided, or the range can be modified in the field using a handheld HART communicator. The other models can be configured using a USB modem and a PC running the free software provided. All models can be ordered with Pt100 RTD, J, K, T thermocouples; see Ordering Information for model numbers.


      PD301 - PD306 Head Mount Models

      The head mount models are offered as: hockey-puck only (PD301 & PD302) which can be mounted inside a DIN Form B connection head, pre-mounted in a connection head (PD303 & PD304), and pre-mounted in a connection head with temperature probe (PD305 & PD306). The PD302, PD304, and PD306 include HART communication capability. Standard enclosed models have an aluminum connection head with a 1/2" NPT conduit hole and 1/2" NPT process opening for a probe or adapter fitting, and are available with safe area (NEMA 4X, IP66 rated), or Certified explosion-proof housings. Non-standard models with other conduit hole and process opening sizes, as well as an optional stainless steel housing are available, visit the ExSense Builder.


      PD310 & PD312 Enhanced Display Models

      The enhanced display models, with standard loop-powered backlight, let the user see the display under any lighting condition, and present valuable information such as the process variable, input type, engineering units, and bargraph. The display can be configured to show the PV, mA output, or %. These models are housed in a sleek & rugged die-cast NEMA 4X enclosure that is available in general purpose and explosion-proof versions. The enclosure has two 1/2" NPT conduit holes, and one 1/2" NPT process sensor connection port for probe or adapter fitting. Non-standard models with other conduit hole and process opening sizes are available, see the ExSense Builder。 For remote mounting applications the PD310 may be ordered without the process sensor connection port.


      APPLICATIONS

      The ExSense packaging lends itself for duty in harsh environments. The good looking die-cast aluminum NEMA 4X housing affords serious protection from the elements, impact damage, corrosion, and electrical interference; it is also explosion-proof. It can be installed almost anywhere. The display models have very flexible installation options. The built-in mounting ears allow for wall, or pipe mounting, and include a rotatable meter. All ExSense systems can be also surface mounted via the thermowell.




      330° Rotatable LCD Display

      Mount the product at any convenient angle and rotate the internal display for best viewing angle.




      PD312 HART Transmitter & Remote Display

      In this application the Smart HART Explosion-Proof Temperature Transmitter is being powered by the PD6000 dual-scale meter; the meter displays the temperature on the top and the mA current on the bottom display. A PLC, DCS, or other devices could be connected in the loop as shown. The 250 ohm resistor is the minimum loop resistance needed for HART communication with a HART modem or a HART communicator.




      PD306 HART Head Transmitter ExSenseView PC Software & Remote Display

      In this application the Smart Transmitter is mounted in the explosion-proof connection head and is being powered by the PD6000 dual-scale meter. The HART communicator and HART modem are used during configuration or troubleshooting.

      CONFIGURATION

      PD301 - PD306 PC Configuration



      PD302 HART Configuration*



      PD310 & PD312 HART Configuration



      * Transmitters can be compley configured using the ExSenseView PC software and modem. HART models can also be configured using a HART Communicator (with the exception of input Type and Units).



      ExSenseView PC Software

      The Current Setup window is used to trim the analog output to match the device reading the current. Click on Read and type the values in the boxes. Click on Update to upload the new values to the transmitter. Test your loop by selecting a Fix Loop value and clicking Send.

      The Parameter Setup window is used to set up the input type, range for the 4-20 mA, temp units, and other settings related to the sensor and analog output. You can also select to display PV, mA, or %.

      The HART Information window allows you to configure or read the transmitter information and to modify the HART address.

      The Graph Monitor window is used to monitor the PV, mA,
      and %. You can also monitor just one of the variables. A log data file can be saved for later viewing; it contains the time, data value, and units. The screen update rate is selectable between 2 sec and 30 min.

      TRANSMITTER INPUT TYPES, RANGES, AND ACCURACY

      Input Type Transmitter Input Range Accuracy
      (% of Span)
      Min Output Span
      (4-20 mA)
      RTD Pt100 -200 to 850°C (-328 to 1562°F) ±0.08% (±0.2°C min) 10°C (18°F)
      Pt500 -200 to 250°C (-328 to 482°F) ±0.2% (±0.5°C min) 10°C (18°F)
      Pt1000 -200 to 250°C (-328 to 482°F) ±0.12% (±0.3°C min) 10°C (18°F)
      Cu50 -50 to 150°C (-58 to 302°F) ±0.08% (±0.2°C min) 10°C (18°F)
      Cu100 -50 to 150°C (-58 to 302°F) ±0.12% (±0.3°C min) 10°C (18°F)
      Ni100 -60 to 180°C (-76 to 356°F) ±0.08% (±0.2°C min) 10°C (18°F)
      Ni500 -60 to 180°C (-76 to 356°F) ±0.20% (±0.5°C min) 10°C (18°F)
      Ni1000 -60 to 150°C (-76 to 302°F) ±0.12% (±0.3°C min) 10°C (18°F)
      Potentiometer Resistance 0 to 400 Ω ±0.08% (±0.1 Ω min) 10 Ω
      0 to 2,000 Ω ±0.12% (±1.5 Ω min) 100 Ω
      TC B 0 to 1820°C ( 32 to 3308°F) ±0.08% (±2.0°C min) 500°C (900°F)
      E -270 to 1000°C (-454 to 1832°F) ±0.08% (±0.5°C min) 50°C (90°F)
      J -210 to 1200°C (-346 to 2192°F) ±0.08% (±0.5°C min) 50°C (90°F)
      K -270 to 1372°C (-454 to 2501°F) ±0.08% (±0.5°C min) 50°C (90°F)
      N -270 to 1300°C (-454 to 2372°F) ±0.08% (±1.0°C min) 50°C (90°F)
      R -50 to 1768°C ( -58 to 3214.4°F) ±0.08% (±2.0°C min) 500°C (900°F)
      S -50 to 1768°C ( -58 to 3214.4°F) ±0.08% (±2.0°C min) 500°C (900°F)
      T -270 to 400°C (-454 to 752°F) ±0.08% (±0.5°C min) 50°C (90°F)
      C 0 to 2320°C (32 to 4208°F) ±0.08% (±0.5°C min) 50°C (90°F)
      D 0 to 2320°C (32 to 4208°F) ±0.08% (±0.5°C min) 50°C (90°F)
      Voltage mV -10 to 75 mV ±0.08% (±20µV min) 5 mV
      -100 to 100 mV ±0.08% (±20µV min) 5 mV
      -100 to 500 mV ±0.08% (±30µV min) 6 mV
      -100 to 2000 mV ±0.08% (±50µV min) 20 mV


      COMPLETE TEMPERATURE ASSEMBLY

      Simplify your ordering process by getting a complete temperature assembly from Precision Digital. Use the online ExSense Builder to select your transmitter, temperature probe, and thermowell; specify the temperature range and you will get all the parts needed for your temperature system. Avoid the headaches of getting components that do not match, from different suppliers. Order a complete temperature assembly from Precision Digital and make your life easier.




       

      ACCESSORIES

      RTD Probes & Thermowells



      RTD probes are offered in 6", 9", and 12" lengths and ¼" diameter; other sizes are available upon request. Spring-loaded probes and thermowells are special order; please consult the factory for details.




      TC & RTD Connection Heads

      • General Purpose & Explosion-Proof
      • Aluminum & Stainless Steel
      • NEMA 4X, IP66 Rated
      • Stainless Steel Ball Chain
      • Spring-Loaded 2" Ceramic Block Available

      CONNECTIONS

      PD301 - PD306



      PD310 & PD312



      DIMENSIONS

      PD301 & PD302



      PD310 & PD312



      Thermowell Type T1

      PD303 & PD304




      MOUNTING










      SPECIFICATIONS

      General

      Input: Universal RTD, TC, Resistance, or Voltage
      Power Supply: 7.5 to 45 VDC, reverse polarity protected
      Storage Temperature: -40 to 100°C
      Connections: Screw terminals accept 12 to 22 AWG
      Output: Two-wire 4-20 mA scalable
      Accuracy: ±0.08% of span typical, see table on page 5 for details
      Temperature Drift: RTD: ±0.004°C/°C; TC: ±0.03°C/°C
      Underrange: 3.8 mA
      Overrange: 20.8 mA
      Sensor Break: Selectable ≤3.6 mA Low Alarm or ≥22 mA High Alarm
      Response Time: 1 second
      Long Term Stability: Better than 0.05% per year
      Start Up Time: Less than 5 seconds
      Noise Filter: Configurable from 0 to 85 µA
      Damping Time: Configurable from 0 to 30 sec
      Output Resolution: 0.3 µA
      Non-Volatile Memory: All configured settings are stored in non-volatile memory for a minimum of ten years.
      Relative Humidity: 0 to 90%, condensation allowed
      Isolation: 2 kV input-to-output
      Shock & Vibration Resistance: 4g/2 to 150 Hz as per IEC 60 068-26
      EMC: Immunity & emission interference according to GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
      Warranty: 1 year parts & labor


      PD310 & 312 Exp-Proof Smart Transmitter

      Display: PV: 0.3" (8 mm) 5-digit LCD, Input & Units: 0.2" (5 mm)
      Bargraph: 52 segments with 2% resolution
      Backlight: Loop-powered, always on
      Configuration Method: PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
      Load Impedance: 650 Ω @ 24 VDC max or ((V supply - 10.5 V)/0.0208 A) Ω
      Operating Temperature: -30 to 75°C
      Enclosure: Explosion-proof or general purpose die-cast aluminum, 0.3% max copper content, NEMA 4X, IP66; two ½" NPT conduit holes, one ½" NPT process connection; other sizes available upon request.
      PD310-A2 & PD312-A2 Approvals: FM: Explosion-proof for Class I, Division 1, Groups B, C and D; dust-ignition-proof for Class II/III, Division 1, Groups E, F and G, hazardous (classified) locations, indoors and outdoors (Type 4X/IP66)
      CSA: Explosion-proof for Class I, Division 1, Groups B, C and D; dust-ignition-proof for Class II/III, Division 1, Groups E, F and G, hazardous (classified) locations, indoors and outdoors (Type 4X/IP66)
      ATEX: II 2 G D, Ex d IIC, Ex tD A21, IP68, Ta = -40°C to +85°C
      IECEx: Ex d IIC, Ex A21 tD, IP68, Ta = -40°C to +85°C
      Weight: 2.42 lb (1.10 Kg)
      Overall Dimensions: 4.30" x 4.27" x 3.62" (109.2 x 108.4 x 92.0) (W x H x D), probe and thermowell not included


      PD301 & 302 Head Mount Smart Transmitter

      Configuration Method:
          PD301: PDA8301 USB modem and PC software
          PD302: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
      Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω
      Operating Temperature: -40 to 85°C
      Enclosure: Polycarbonate housing with epoxy potting, NEMA 1, IP00 (NEMA 4X, IP66 with PDA1080WM)
      Weight: 1.18 oz (33.5 g)
      Overall Dimensions: Dia. 1.73" x 0.89" (44 mm x 22.5 mm)
      Installation Angle: No limit
      Installation Area: Connection head according to DIN 43 729 Form B


      PD303 & PD304 Head-Mounted Smart Transmitter

      Configuration Method:
          PD303: PDA8301 USB modem and PC software
          PD304: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
      Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω
      Operating Temperature: -40 to 85°C
      Enclosure: Aluminum or 316 SS mounting head NEMA 4X, IP66 with optional explosion-proof Certification. Note: The Certification applies to the connection head only and not to the transmitter assembly.
      Weight: 1.0 lb (453.6 g)
      Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm)
      Installation Angle: No limit
      Installation Area: Connection head according to DIN 43 729 Form B


      PD305 & PD306 Head-Mounted Smart Transmitter with Thermowell and/or Probe

      Configuration Method:
          PD305: PDA8301 USB modem and PC software
          PD306: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
      Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω
      Operating Temperature: -40 to 85°C
      Enclosure: Aluminum or 316 SS mounting head NEMA 4X, IP66 with optional explosion-proof Certification
      Weight: 1.0 lb (453.6 g) plus probe/thermowell weight
      Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm) plus probe/thermowell length
      Installation Angle: No limit
      Installation Area: Connection head according to DIN 43 729 Form B
      * The Input Type and Units cannot be changed with HART Communicators (e.g. HC275, HC375).


      Connection Heads

      Material: Die-cast aluminum or 316 stainless steel
      Certification: FM/CSA/ATEX Explosion-proof Certified, NEMA 4X, IP66 or general purpose without certification
      Connections: Two ½" NPT for conduit and process connection; other sizes available upon request
      Mounting Holes: Accept M4 screws, see dimensions drawing
      Surface Finishing: Aluminum: Blue epoxy coated,
          Stainless steel: Electropolished
      O-Ring: Buna-N
      Weight: Aluminum: 0.450 kg (1.0 lb), Stainless steel: 0.90 kg (2.0 lbs)
      Features: SS ball chain included, terminal block (Ceramic/Bakelite optional)
      Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm)


       

      ExSense Builder



      To help build the correct model number for your application, use the online ExSense Builder. This online tool can be accessed by clicking on any of the links provided.
      After a transmitter type selection is made the following options are available:












      Options Availability
      Configuration Setup
      C0: Factory Default
      C1: Custom Configuration
      C2: Custom Configuration with Certificate of Calibration
      All transmitter types
      Enclosure
      A2: Exp-Proof Aluminum Enclosure, ½" NPT
      G2: Safe Area Aluminum Enclosure, ½" NPT
      S2: Exp-Proof Stainless Steel, ½" NPT
      Note: Additional conduit & process connections are available upon request.
      All, except PD301 & PD302

      Note: Stainless steel enclosure option is not available with PD310 or PD312
      Temperature Probe (¼" diameter)
      P11R04: Pt100 RTD 3-Wire, 4" Rigid Probe, 0.385
      P11R06: Pt100 RTD 3-Wire, 6" Rigid Probe, 0.385
      P11R09: Pt100 RTD 3-Wire, 9" Rigid Probe, 0.385
      P11R12: Pt100 RTD 3-Wire, 12" Rigid Probe, 0.385
      P11S04: Pt100 RTD 3-Wire, 4" Spring-Loaded, 0.385
      P11S06: Pt100 RTD 3-Wire, 6" Spring-Loaded, 0.385
      P11S09: Pt100 RTD 3-Wire, 9" Spring-Loaded, 0.385
      P11S12: Pt100 RTD 3-Wire, 12" Spring -Loaded, 0.385
      Note: Additional sensors and probe sizes are available upon request.
      PD305, PD306, PD312
      Thermowell
      T104: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 4" Probe
      T106: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 6" Probe
      T109: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 9" Probe
      T112: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 12" Probe
      PD305, PD306, PD312 with S06, S09, S12 options
      Note: If the product requires a temperature sensor, select a picture showing a temperature probe, the ExSense Builder will include the steps to select the temperature sensor.

      Note: Standard RTD is 1/4" in diameter , stainless steel, 400°F max. For other sizes and temperature ranges, contact the factory.

      Once a new model is generated using the ExSense Builder, you will
      1. see the price of the full model number built
      2. have the opportunity to purchase the product
      3. have the ability to us, yourself, or a third person the model number built

      Note: HART models must be configured using the ExSenseView PC software and PDA8302 HART modem. The Input Type and Units cannot be changed with HART Communicators (e.g. HC275, HC375).

      Go to the ExSense Builder to build a complete model number and get pricing.

      Example 1: PD301-C0 Head mount temperature transmitter with factory defaults
      Example 2: PD310-G2-C1 HART temperature transmitter with display, general purpose, custom configuration
      Example 3: PD312-G2-C1-P11S06-T106
      PD312 = HART temperature transmitter with display & temperature probe
      G2 = Rugged general purpose NEMA 4X enclosure
      C1 = Custom configuration
      P11 = 100 Pt RTD with 6" leads
      S06 = Spring-loaded 6" probe for thermowell installation
      T106 = Type 1 thermowell to match 6" spring-loaded probe


      Example of Other Options:
      • C0 = Factory default configuration
      • A2 = Explosion-proof die-cast aluminum enclosure
      • C2 = Custom configuration with Certificate of Calibration
      • R06 = 6" Rigid probe

      RTD/TC Connection Head Assembly
      PDA1080WM head shown with PDA8059-04-EG terminal block
      在找 PD312型HART系列溫度變送器(帶現(xiàn)場顯示和傳感器) 產(chǎn)品的人還在看
      返回首頁 產(chǎn)品對比

      提示

      ×

      *您想獲取產(chǎn)品的資料:

      以上可多選,勾選其他,可自行輸入要求

      個人信息:

      Copyright gkzhan.com , all rights reserved

      智能制造網(wǎng)-工業(yè)4.0時代智能制造領(lǐng)域“互聯(lián)網(wǎng)+”服務(wù)平臺

      對比欄