      深圳灣邊貿(mào)易優(yōu)勢進(jìn)口Amptek XR-100CR X射線探測器*

      參  考  價:面議
      具體成交價以合同協(xié)議為準(zhǔn)

      產(chǎn)品型號XR-100CR

      品牌

      廠商性質(zhì)代理商

      所在地深圳市

      更新時間:2016-08-30 00:19:45瀏覽次數(shù):640次

      聯(lián)系我時,請告知來自 智能制造網(wǎng)
      TheXR-100CR系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 X射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器(

       

      深圳灣邊貿(mào)易公司            

      深圳灣邊貿(mào)易進(jìn)口代理Amptek XR-100CR X射線探測器*!Amptek X射探測系統(tǒng),Amptek X光檢測儀,  Amptek手執(zhí)X射線探測器*!

       

      TheXR-100CR系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 系列產(chǎn)品由高性能 X射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成* 射線探頭,前置放大器()和致冷系統(tǒng)組成

       

      TheXR-100CRis a high performancex-ray detector,preamplifier, andcoolersystem using a thermoelectrically cooled Si-PIN photodiode as an x-ray detector. Also mounted on the 2-stage cooler are the input FET and a novel feedback circuit. These components are kept at approximay -55 °C, and are monitored by an internal temperature sensor. The hermetic TO-8 package of the detector has a light tight, vacuum tight thin Beryllium window to enable soft x-ray detection.

      The XR-100CR represents a breakthrough in x-ray detector technology by providing "off-the-shelf" performance previously available only from expensive cryogenically cooled systems.

      Features

      • Si-PIN Photodiode
      • 2-Stage Thermoelectric Cooler
      • Temperature Monitor
      • Beryllium Window
      • Multilayer Collimator
      • Hermetic Package (TO-8)
      • Wide Detection Range
      • Easy to Operate

      Additional Information

      • Selection Guide
      • Additional Performance Spectra and Detector Properties
      • Application Spectra
      • Si-PIN vs. CdTe
      • Mechanical Dimensions
      • Multilayer Collimator
      • OEM & Custom Applications

      Accessories

      • MP1 XRF Mounting Plate
      • Vacuum Applications
      • Collimator Kit (high flux applications)
      • Experimenter's XRF Kit

      Applications

      • X-Ray Fluorescence
      • RoHS/WEEE
      • Portable Instruments
      • OEM
      • Nuclear Medicine
      • Teaching and Research
      • Art and Archaeology
      • Process Control
      • Mössbauer Spectrometers
      • Space and Astronomy
      • Environmental Monitoring
      • Nuclear Plant Monitoring
      • Toxic Dump Site Monitoring
      • PIXE
      x-ray detector element

      xr100cr x-ray detector with 145 eV Resolution!
      Figure 1.55Fe Spectrum taken with a 6 mm2/500 µm detector.

      The resolution for the the 5.9 keV peak of55Fe is 145 eV FWHM to 230 eV FWHM depending on detector type and shaping time constant. SeeSelection Guide.

      Theory of Operation

      X-rays interact with silicon atoms to create an average of one electron/hole pair for every 3.62 eV of energy lost in the silicon. Depending on the energy of the incoming radiation, this loss is dominated by either the Photoelectric Effect or Compton scattering. The probability or efficiency of the detector to "stop" an x-ray and create electron/hole pairs increases with the thickness of the silicon.See efficiency curves.

      In order to facilitate the electron/hole collection process, a 100-200 volt bias voltage is applied across the silicon depending on the detector thickness. This voltage is too high for operation at room temperature, as it will cause excessive leakage, and eventually breakdown. Since the detector in the XR-100CR is cooled, the leakage current is reduced considerably, thus permitting the high bias voltage. This higher voltage decreases the capacitance of the detector, which lowers system noise.

      The thermoelectric cooler cools both the silicon detector and the input FET transistor to the charge sensitive preamplifier. Cooling the FET reduces its leakage current and increases the transconductance, both of which reduce the electronic noise of the system.

      Since optical reset is not practical when the detector is a photodiode, the XR-100CR incorporates a novel feedback method for the reset to the charge sensitive preamplifier. The reset transistor, which is typically used in most other systems has been eliminated. Instead, the reset is done through the high voltage connection to the detector by injecting a precise charge pulse through the detector capacitance to the input FET. This method eliminates the noise contribution of the reset transistor and further improves the energy resolution of the system.

      A temperature monitor diode chip is mounted on the cooled substrate to provide a direct reading of the temperature of the internal components, which will vary with room temperature. Below -20 癈, the performance of the XR-100CR will not change with a temperature variation of a few degrees. Hence, closed loop temperature control is not necessary when using the XR-100CR at normal room temperature. For OEM applications or hand held XRF instrumentation a closed loop temperature control is recommended. The Active Temperature Control is standard in Amptek electronics such as the PX5 and DP5/PC5.

       

      XR100-CR Specifications

      General
      Detector TypeSi-PIN
      Detector Sizes6 mm2(collimated to 4.4 mm2
      13 mm2(collimated to 11.1 mm2
      25 mm2(collimated to 21.5 mm2
      See Selection Guide
      Silicon Thickness500 µmSee efficiency curves
      CollimatorMultilayer,click here for more information
      Energy Resolution @ 5.9 keV (55Fe)145 eV FWHM to 230 eV FWHM depending on detector type and shaping time constant.
      See Selection Guide
      Background Counts<5 x 10-3/s, 2 keV to 150 keV for 6 mm2/500 µm detector
      Detector Be Window Thickness1 mil (25 µm),or 0.5 mil (12.5 µm),See transmission curves
      Charge Sensitive PreamplifierAmptek custom design with reset through the H.V. connection
      Gain Stability<20 ppm/°C (typical)
      Case Size3.00 x 1.75 x 1.13 in (7.6 x 4.4 x 2.9 cm),See mechanical dimensions
      Weight4.9 ounces (139 g)
      Total Power<1 Watt
      Warranty Period1 Year
      Typical Device Lifetime5 to 10 years, depending on use
      Operation conditions0°C to +40°C
      Storage and ShippingLong term storage: 10+ years in dry environment
      Typical Storage and Shipping: -20°C to +50°C, 10 to 90% humidity non condensing
      TUV CertificationTUV Certification
      Certificate #: CU 72072412 01
      Tested to: UL 61010-1: 2004 R7 .05
      CAN/CSA-C22.2 61010-1: 2004
      Inputs
      Preamp Power±8 to 9 V @ 15 mA with no more than 50 mV peak-to-peak noise
      Detector Power+180 V (power supply should be able to produce between +100 to 200 V @ 1 µA) very stable <0.1% variation
      Cooler PowerCurrent = 350 mA maximum, voltage = 4 V maximum with <100 mV peak-to-peak noise
      Note: the XR-100CR includes its own temperature controller

      NORMATEC PULSE體能快速恢復(fù)系統(tǒng)

      NORMATEC PULSE體能快速恢復(fù)系統(tǒng),Normatec為一款能

      優(yōu)勢供應(yīng)加拿大Spaenaur螺母Spaenaur螺絲

      優(yōu)勢供應(yīng)加拿大Spaenaur螺母Spaenaur螺絲$r$n深圳灣邊

      美國Hitec Products應(yīng)力計電組絲

      美國Hitec Products應(yīng)力計電組絲$r$n深圳市灣邊貿(mào)易有限

      會員登錄

      ×

      請輸入賬號

      請輸入密碼

      =

      請輸驗證碼

      收藏該商鋪

      X
      該信息已收藏!
      標(biāo)簽:
      保存成功

      (空格分隔,最多3個,單個標(biāo)簽最多10個字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時間回復(fù)您~

      以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對此不承擔(dān)任何保證責(zé)任。

      溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

      在線留言