PIPE TEMPERATURE TRANSMITTER(GPTO-420) | | | "GPTO" Pipe Temperature Transmitter is intended for sensing pipe and tank temperature : Fluids temperature control and limit Circulating water temperature control and limit Water temperature at home control and limit
| | Supply Voltage | : DC 15 ~ 30V | | Output Signal | : 4 ~ 20 mA
| | Range | : 0 ~ +150℃ , (-50 ~ +300℃)
| | Accuracy | : ± 0.3°C
| Wiring | : 2 Wire
| Sensing Time | : Approx. 20 Sec.
| | | AMBIENT TEMPERATURE | :1) On Operation : -30 ~ +150 ℃ 2) On Storage : -10 ~ +80°C | | AMBIENT HUMIDITY | : 5 ~ 95 % Rh | | PROTECTION CLASS | : IP 54 | Weight | : 0.46 Kg(W/WELL) | | Length | : 130 mm
| | Cover | : Aluminum die-cast
| | Well | : SS304 | | | | Use drill bar for WELL at over 6Kg/cm of Nominal pressure. Install Transmitter to following location per each different usage 1) Hydraulic temperature control ( for cold and warm water ) - In case of installing inside of hydraulic body : right behind of pump - In case of installing on the line of ventilating water : away from 1.5 ~2 meter away from mixed valve 2) Ventilating water temperature control - Install inside of Pipe to sense accurate limit temperature at the location of well water mixing point Install WELL at elbow location to be reversed from Hydraulic | | PIPE TEMPERATURE TRANSMITTER(GPTO-105) | | | "GPTO" Pipe Temperature Transmitter is intended for sensing pipe and tank temperature : Fluids temperature control and limit Circulating water temperature control and limit Water temperature at home control and limit
| | Supply Voltage | : 15 ~ 30V DC | | Output Signal | : 1 ~ 5V DC
| | Range | : 0 ~ +150℃ , (-50 ~ +300℃)
| | Accuracy | : ± 0.3°C
| Wiring | : 2 Wire
| Sensing Time | : Approx. 20 Sec.
| | | AMBIENT TEMPERATURE | :1) On Operation : -30 ~ +150 ℃ 2) On Storage : -10 ~ +80°C | | AMBIENT HUMIDITY | : 5 ~ 95 % Rh | Cable Fitting | : PF1/2"
| | PROTECTION CLASS | : IP 54 | Weight | : 0.46 Kg(W/WELL) | | Length | : 130 mm
| | Cover | : Aluminum die-cast
| | Well | : SS304 | | | | Use drill bar for WELL at over 6Kg/cm of Nominal pressure. Install Transmitter to following location per each different usage 1) Hydraulic temperature control ( for cold and warm water ) - In case of installing inside of hydraulic body : right behind of pump - In case of installing on the line of ventilating water : away from 1.5 ~2 meter away from mixed valve 2) Ventilating water temperature control - Install inside of Pipe to sense accurate limit temperature at the location of well water mixing point Install WELL at elbow location to be reversed from Hydraulic.
| | |