RTD : Converter
(RTD(Temperture) -> DC
Converter
The Model RTD accepts 2- or 3-wire RTD inputs and provides isolated and linearized DC outputs.
MODEL & SUFFIX CODE
RTD-(model)(in)(out1)(out2)-(power)
-(model)
2 : 1 Output with Display
4 : 1 Output without Display
7 : 2 Outputs with Display
9 : 2 Outputs without Display
(input)
A : -50 ~ +50 C for JIS spec. B : 0 ~ 50 C for JIS spec.
C : 0 ~ 100 C for JIS spec. D : 0 ~ 200 C for JIS spec.
E : 0 ~ 300 C for JIS spec. F : 0 ~ 400 C for JIS spec.
G : -50 ~ +50 C for DIN spec. H : 0 ~ 50 C for Din spec.
I : 0 ~ 100 C for DIN spec. J : 0 ~ 200 C for DIN spec.
K : 0 ~ 300 C for DIN spec. L : 0 ~ 400 C for DIN spec.
R : Other Special Spec.
(output1)(output2)
1 : DC 0~10mV (Load Resistance : 10 Kohm or more)
2 : DC 0~100mV (Load Resistance : 100 Kohm or more)
3 : DC 0~5V (Load Resistance : 5 Kohm or more)
4 : DC 0~10V (Load Resistance : 10 Kohm or more)
5 : DC 1~5V (Load Resistance : 5 Kohm or more)
6 : DC 0~1mA (Load Resistance : 0~15 Kohm)
7 : DC 0~20mA (Load Resistance : 0~750 ohm)
8 : DC 4~20mA (Load Resistance : 0~750 ohm)
R : Other Special Spec.
N : Not Used
-(power)
W : AC 200~230V for 60 Hz
X : AC 100~120V for 60 Hz
Y : DC 18~30V
Z : Other Special Spec.