a thermocouple and provides isolated
porportional DC outputs.
MODEL: CDI-TCC
MODEL TYPE
INPUT
OUTPUT 1
POWER
1 : 1 Output
2 : 2 Output
A : 1 Output with display
B : 2 Output with display
X : AC 110V or 220V for 50/60Hz
Y : DC 24V
Z : Other special power
- Construction : Plug -in
- Wring : M3.5 Screw Terminal
- Isolation : Power to Input to Output1
to Output2
- Adjustment : Zero & Span± 20%of full scale
- Operating temperature : -5℃ ~ 55℃
- Operating humidity : 90%RH Max
(none condensing)
- Power supply
AC : 110V or 220V/60Hz ±10%,approx 3VA
DC : 18V ~ 30V ±10%,approx 3VA
- Power selection : AC 110V/220V Swich
in the back plane
- Mounting : Wall or DIN rail
- Accuracy : ± 0.3% of full scale
- Temp'coefficient : ±0.015/℃
- Response time : 0.5 Sec or less(0~90%)
- Insulation resistance : 100MΩor more
with 500VDC(Input/Output/Power)
- Dielectric strength : 1500VAC at 1minute
(Input to Output to Power)
1 : "K" type(CA)
2 : "J" type(IC)
3 : "R" type
4 : "T" type(CC)
5 : "S" type
6 : "E" type(CRC)
7 : "B" type(RH)
O : Other special type
CDI TECH CO.,LTD.
MODEL CDI - TCC
THERMOCOUPLE CONVERTER
GENERAL SPECIFICATION
INPUT
- Input type : Thermocouple
- Impedance : 30KΩ
- Minimum span : 3mV
- DC VOLTAGE : ±12V Max
- Load Resistance
Output Resistance
0 ~ 10mV 1KΩor more
0 ~ 100mV 1KΩ or more
0 ~ 1V 1KΩ or more
0 ~ 5V 2KΩ or more
0 ~ 10V 4KΩ or more
-10V ~ 10V 4KΩ or more
- DC CURRENT : 0 ~ 20mA
- Load Resistance
Output Resistance
0 ~ 1mA 15KΩor less
0 ~ 10mA 1.5KΩ or less
0 ~ 20mA 750Ω or less
1 ~ 5mA 3KΩ or less
4 ~ 20mA 750Ω or less
OUTPUT
INSTALLATION
PERFORMANCE
ORDERING CODE SELECTION