您好, 歡迎來到智能制造網(wǎng)! 登錄| 免費注冊| 產(chǎn)品展廳| 收藏商鋪|
當前位置:北京明尼克分析儀器設備中心>>GC-PLOT柱>> Rt®-Alumina BOND/KCl Columns(熔融石英plot柱)
參 考 價 | 面議 |
產(chǎn)品型號
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地北京市
更新時間:2024-12-22 08:16:28瀏覽次數(shù):27次
聯(lián)系我時,請告知來自 智能制造網(wǎng)Rt®-Msieve 5A Columns(熔融石英plot柱
Rt®-Alumina BOND/Na2SO4 Columns
Rt®-Alumina BOND/KCl Columns(熔融
Rt®-Alumina BOND/CFC Columns(熔融
Rt®-Alumina BOND/KCl Columns (fused silica PLOT)
(KCl deactivation)
Guaranteed Reproducibility
Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene.
With our new technology, both Na2SO4 and KCl are available with the Rt®-Alumina BOND columns.
Similar Phase(s):
GC-Alumina KCl, CP-Al2O3/KCl
catalog # | length | id | df | units | |
19761 | | | 5μm | ea. | |
19762 | | | 5μm | ea. | |
19759 | | | 10μm | ea. | |
19760 | | | 10μm | ea. | |
Showing 1 to 4 of 4 entries
1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to
Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.
Acetylene elutes before C4 hydrocarbons (impurities in butane/isobutane).
Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene.
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關企業(yè)負責,智能制造網(wǎng)對此不承擔任何保證責任。
溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。