上海倍加福工業(yè)自動化貿(mào)易有限公司
您現(xiàn)在的位置: 上海倍加福工業(yè)自動化貿(mào)易有限公司>>工業(yè)電源>> PS1000-A6-24.20
PS1000-A6-24.20
參考價: | 面議 |
- 產(chǎn)品型號
- 品牌
- 其他 廠商性質(zhì)
- 所在地
訪問次數(shù):125更新時間:2023-10-06 19:44:18
聯(lián)系我們時請說明是智能制造網(wǎng)上看到的信息,謝謝!
產(chǎn)品介紹
技術參數(shù)節(jié)選 PS1000-A6-24.20
Electrical specifications | ||
---|---|---|
Efficiency | 94.2 % at 120 V AC 95.6 % at 230 V AC | |
Power dissipation | 29.6 W at 120 V AC 22.1 W at 230 V AC | |
Input | ||
Voltage range | 100 ... 240 V AC (-15 %/+10 %), 50 ... 60 Hz (±6 %) 110 ... 150 V DC (±20 %) | |
Current | 4.26 A at 120 V AC 2.23 A at 230 V AC 4.64 A at 110 V DC for lower output currents see technical information | |
Inrush current | 10 A peak at 120 V AC, temperature independent 4.5 A peak at 230 V AC, temperature independent | |
Capacity factor | 0.99 at 120 V AC 0.98 at 230 V AC | |
Output | ||
Rated voltage | 24 V DC | |
Voltage range | 24 ... 28 V DC factory setting: 24.1 V | |
Rated current | 20 A | |
Current | 24 ... 20.6 A at ambient temperature < 45="" °c="" (113="" °f)=""> 20 ... 17.1 A at ambient temperature 60 °C (140 °F) 15 ... 13 A at ambient temperature 70 °C (158 °F) linear power derating see technical information | |
Power | 480 W | |
Ripple | max. 50 mV pp | |
Hold-up time | 32 ms at 120 V AC 32 ms at 230 V AC | |
Overload behavior | continuous current : output voltage > 13 V DC intermittent current : output voltage < 13="" v=""> | |
Short-circuit current | typ. 29 A intermitted current peak value for typ. 2 s | |
Voltage limitation | typ. 30.5 V DC max. 32 V DC | |
Fault indication output | ||
Connection | terminals 13, 14 | |
Output type | relay contact DC OK - contact is closed if the output voltage is > 90 % of the adjusted output voltage | |
Contact loading | max. 60 V DC/0.3 A ; 30 V DC/1 A ; 30 V AC/0.5 A resistive load min. 1 mA at 5 V DC | |
Galvanic isolation | ||
Input/Output | SELV/PELV | |
Indicators/settings | ||
Display elements | LED green: status DC OK - LED lights up if the output voltage is > 90 % of the adjusted output voltage | |
Control elements | potentiometer , plug-in jumper | |
Configuration | setting of the output voltage via potentiometer setting of the operating mode - plug-in jumper plugged in: "parallel use" operating mode - plug-in jumper not plugged in: "single use" operating mode | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | IEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4 , IEC/EN 61000-3-2 , IEC/EN 61000-3-3 | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1 | |
RoHS | ||
Directive 2011/65/EU (RoHS) | IEC/EN 63000:2019 | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) , see technical information | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 5 ... 95 %, noncondensing | |
Shock resistance | 20 g , 11 ms or 30 g , 6 ms | |
Vibration resistance | 2 ... 17.8 Hz : ± 1.6 mm , 17.8 ... 500 Hz : 2 g | |
Mechanical specifications | ||
Housing material | aluminum alloy , galvanized steel | |
Degree of protection | IP20 | |
Connection | ||
Input/Output | screw terminals conductor cross section: max. 6 mm2 (AWG 20-10) cable diameter: max. 2.8 mm, wire end ferrules included stripped insulation length: 7 mm tightening torque: max. 1 Nm | |
Relay contact output | spring terminals with push-in connection technology conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm | |
Mass | approx. 830 g | |
Dimensions | 48 x 124 x 127 mm , without plugs and without DIN mounting rail | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
ATEX approval | ||
ATEX certificate | EPS 17 ATEX 1 089 X | |
ATEX marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E350173 , E223176 | |
IECEx approval | ||
IECEx certificate | IECEx EPS 20.0056X | |
IECEx marking | Ex ec nC IIC T4 Gc | |
Standards | IEC 60079-0:2011 , IEC 60079-7:2015 , IEC 60079-15:2010 | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see . |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | |
ECLASS 12.0 | |
ECLASS 11.0 | |
ECLASS 10.0.1 | |
ECLASS 9.0 | |
ECLASS 8.0 | |
ECLASS 5.1 | |
ETIM 9.0 | EC002542 |
ETIM 8.0 | EC002542 |
ETIM 7.0 | EC002542 |
ETIM 6.0 | EC002542 |
ETIM 5.0 | EC002542 |
UNSPSC 12.1 |