      Name

      LEVEL  INDICATING
      CONTROLLER

      Model

      2L-LIC-D

       Input Voltage

      AC 220V (100V
      separate order)

      Contact Point
      Capacity

      CONTROL AC 220V 5A

      HI/LO AC 220V 3A

      Input

      input current (4~20mA)

      Function

      Indication , water supply/draining automation and alarm for high/low water level in various kind of tank

      Indication , water supply/draining   automation and alarm for high/low water   evel in various kind of tank.

          (exterral panel)

      2 Line Parallel Method (Sensor and Indicator Meter) 4~20mA

      Caution : Cannot use for oil, chemicals or                  steam tank (over 80℃)

      Separate Order for High Temperature
          and Special Purpose.

      Model

      2L-LIC-D
      (
      Resistance Input)

       Input Voltage

      AC 220V (100V
      separate order)

      Contact Point
      Capacity

      CONTROL AC 220V 5A

      HI/LO AC 220V 3A

      Feature

      Resistance Input Method (0~300Ω)

      Function

      Indication , water supply/draining automation and alarm for high/low water level in various kind of tank

      Material

      - HEAD  - Nylon Fiber

      - FLOAT- P/P foaming

      - PIPE   - SUS 304

      Model

      2L-LIC-D
      (Current Input)

      Input Voltage

      AC 220V (100V
      separate order)

      Contact Point
      Capacity

      CONTROL AC 220V 5A

      HI/LO AC 220V 3A

      Feature

      Current Input (4~20mA)

       

      Function

      Indication , water supply/draining automation and alarm for high/low water level in various kind of tank

      Material

      - HEAD  - Nylon Fiber

      - FLOAT- P/P foaming

      - PIPE   - SUS 304

       

      2L-LIC-D is the Digital Level Indicating Controller built in a Micom Chip, it can check the indicating value as setting High/Low level alarm and Auto Feeding/Drainage for various kinds of tanks as Digital Mode.  It is the Resistance Input (0~300Ω) Type of level controller built in the function isolating a contact output in case of the line disconnecting or the abnormal condition of sensor.

      Composed easy to control and set-up, it is manufactured to operate strongly against the power noise or the induction of sensor line, etc.

       

      (Resistance Input)

      Using power  :  AC 220V 60HZ 2W (Special order - 100V)

      Contact Capacity  :  5A MAX(LO-AL/HI-AL/Feeding. Drainage Contact)

      Control Output  :  Contact of Feeding. Drainage, LO-AL, HI-AL, 4~20mA)

      Input Signal  :  0~300Ω Resistance(Indicating Meter Sensor & Parallel mode)

      Error  :  ±0.5FS

      Operating condition  :  0~50℃   0~80%RH

      Outer dimension  :  82×160×63 (H×W×D)

      Usage  :  Level indicating Controller for various kinds of Water tanks,
                    Oil tank, etc Sensor is required to use with less than 80℃
                    (Separate order for more than 80℃)

       

      MODE

      When pressing a Mode upon setting up, LED Lamp lights in order;LO-AL>START>STOP>HI-AL

      Indicating Limit

      0%~120% (In case of more than 120%, 'hid' flickers) (0%~99%)

      DN

      Using to decrease the setting value in the position of LED Lamp required

      hid

      In case of line disconnecting, the abnormal condition of sensor or 99% setting is not exact, it flickers

      UP

      Using to increase the setting value in the position of LED Lamp required

      Setting limit

      0%~120% (LO-AL/HI-AL/START/STOP)

      ENT

      After setting values in the setting position of each Mode, press an ENT.  All are remembered.

      Sensor Input

      Voltage mode 0~1.5V (Indicating meter) by a Resistance Input(0~300Ω)

      Reference

      If not press an ENT for 5 sec., it returns to the original display position

      With the first delivery, LO-AL(40%), START(60%), STOP(80%), HI-AL(90%) are set

      When 'hid' flickers, the function of mode won't work

      Reference

      Indicating meter can be connected up to 3 units by Parallel Mode with a Sensor terminal (0~1.5V)

      4~20mA Output Terminal builds in a card (Option) when ordering. (Separate setting or insert is possible)

      Set 99% numeric value as putting a sensor float in 99% position and adjusting 99% set in a unit

       

      2L-LIC-D is the Digital Level Indicating Controller built in a Micom Chip, it can check the indicating value as setting High/Low level Alarm and Auto Feeding/Drainage for various kinds of tanks as Digital Mode.  It is the Current Input (4~20㎃) Type of Level Controller built in the function isolating contact output in case of line disconnecting, short or the abnormal condition of sensor.

      Composed easy to control and set-up, it is manufactured to operate strongly against the power noise or the induction of sensor line, etc

      (Current Input)

      Using power  :  AC 220V 60HZ 2W (Special order - 100V)

      Contact Capacity   :  5A MAX(LO-AL/HI-AL/Feeding. Drainage Contact)

      Control Output   :  Contact of Feeding. Drainage, LO-AL, HI-AL)

      Input Signal  :  4~20MA (Indicating Meter & Sensor Series mode)

      Error  :  ±0.5FS

      Operating condition  :  0~50℃   0~80%RH

      Outer dimension  :  82×160×63 (H×W×D)

      Usage  :  Level indicating Controller for various kinds of Water tanks,
                    Oil tank, etc Sensor is required to use with less than 80℃
                    (Separate order for more than 80℃)

       

      MODE

      When pressing a Mode upon setting up, LED Lamp lights in order;LO-AL>START>STOP>HI-AL

      Indicating Limit

      -3% - 120% (In case of less than -3%, 'oPn' flickers, more than 120%, 'hid' flickers) (0%~99%)

      DN

      Using to decrease the setting value in the position of LED Lamp required

      hid

      In case of more than 120%(more than 20mA, or the abnormal of sensor), it flickers

      oPn

      It flickers in -3% (Less than 4mA or the abnormal of sensor).  (When sensor isn't connected)

      UP

      Using to increase the setting value in the position of LED Lamp required

      Setting limit

      0%~120% (LO-AL/HI-AL/START/STOP)

      ENT

      After setting values in the setting position of each Mode, press an ENT.  All are remembered.

      Sensor Input

      Current mode (Indicating meter 4~20mA series mode) by Current Input(4~20mA)

      Reference

       

      If not press an ENT for 5 seconds, it returns to the original display position

      Upon the first delivery, LO-AL(40%), START(60%), STOP(80%), HI-AL(90%) are set

      When 'hid' flickers, the function of mode won't work

      Reference

       

      Indicating meter for 4-20mA use should be connected with a sensor by Series Mode (Line Resistance 700ΩMAX)

       

      Regulate 0-99%, adjusting SPAN and ZERO inside of a Sensor Head

      Fill the existence of pressure such as non-pressure tank, pressure tank(less than 5 kg) according to the classes of tanks and separate entry is required if temperature is high (more than 80℃).  (Special order in case of more than 5K)

      There are two types; Flange and Screw type.  In case of a Flange type, it should use with 3″(80Φ)4″(100Φ), In case of a Screw type, 2″(50Φ) socket should be welded to a tank.

      Separate order is required for special chemicals and high temperature use.
      (80℃ and more)

       

       

       

      Gear-type Sensor
       

       

       

      Flexible Sensor
       

      As Gear-type sensor hasn't the height of ceiling,  it is ordered and manufactured as a Gear-type when sensor isn't able to put in a tank.

      Refer to the Gear-Type in the tail of 35~36 page

      Temperature should be less than 80℃ only (Oil, Water, etc).

      Special order is required for the chemicals tank such Hydrochloric acid, Sulphuric acid

       

       

       

       

       

       

       

       

       [Attention!] Never use to a Pressure tank

      As Flexible-type sensor hasn't the height of ceiling, it is ordered and manufactured as a Flexible-type when sensor isn't able to put in a tank.

      In the lower part of sensor, the stain weight is an one-touch fitting.  Simple to put a hose in (50mm/m socket-type).

      When handling a sensor, Put a stain weight in first and continue to put with care while remaining a sensor as the original position. (Be careful not to be bent)

      When delivering, deliver as a fixed position to the handling frame (PVC Pipe) and Do not give an impulse or throw.  (It can be the reason of damage)

      Temperature should be less than 80℃ only (Oil, Water, etc)

       

      [Attention!] Never use to a Pressure tank.


      感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

      智能制造網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://towegas.com,All rights reserved.

      以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購(gòu)買(mǎi)風(fēng)險(xiǎn),建議您在購(gòu)買(mǎi)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

      會(huì)員登錄

      ×

      請(qǐng)輸入賬號(hào)

      請(qǐng)輸入密碼

      =

      請(qǐng)輸驗(yàn)證碼

      收藏該商鋪

      請(qǐng) 登錄 后再收藏

      提示

      您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~