      DNP燈箱之燈源采用高頻率螢光燈,其亮度穩(wěn)定適用于數(shù)碼相機(jī),照相手機(jī),錄像機(jī)、安防攝像頭
      車載攝像頭等LENS鏡頭之調(diào)整與測試用穿透式光源裝置。

      DNP透射式光源箱CCV31F/CCV51F全系列

      DNP Standard color Viewer
      The DNP Standard color Viewer is a light source which enables you to evaluate and adjust video and still cameras. With its high-frequency Fluorescent lighting method, it handles images without flicker.
      Specification
      Light source: DNP Standard color Viewer lamp
      (Four 10W dedicated fluorescent tubes are used)
      Power supply: AC100V 50, 60Hz
      Lighting method: High Frequency lighting method 20KHz
      Color rendering: Over 90% rendering evaluation-point for each color
      Color temperature: (Measured by Minolta CL-200)
      Operating temperature: 10~40℃
      Operating humidity: Below 80%(avoid dew)
      Major diameter dimension: 375W×365H×165D m/m
      Luminance plane dimension: 250W×190H m/m
      Color chart dimension: 320W×290H m/m
      Power consumption: 80W
      Weight: 6.5kg/7.5kg
      photo
      CCV-31F
      CCV-51F
      photo
      CCV-31F/G
      CCV-51F/G
      ●The Luminance plane characteristics: according to the types of self-contained fluorescent lamp
      Product Type Luminance Color Temperature Lamp Color Temperature Luminance Color matching shift Weight
      CCV-31F Fixed FL10WW-DLB 3100K±300 Over 1300cd/m2 Within 10% 6.5kg
      CCV-51F Fixed FL10D-EDL-56K 5100K±300 Over 1400cd/m2 Within 10% 6.5kg
      CCV-31F/G Volume adjustable FL-10WW-DLB 3100K±300 Over 850~1300cd/m2 Within 10% 7.5kg
      CCV-51F/G Volume adjustable FL10D-EDL-56K 5100K±300 Over 850~1400cd/m2 Within 10% 7.5kg
      *The color temperature if Luminance. Color Temperature Conversion Type viewer ranges over 50k according to the change of the Luminance.
      *The specification may change without notice
      Operation Manual
      【1】 Before using the product:
        Power supply AC 100V, 50/60Hz shared
      Light source 10W DNP Standard color Viewer Lamp (4)
      Power consumption 80W
      【2】 Using the DNP Standard color Viewer
        (1) Plug the power cable of the product into AC100V
         
      【Precautions】 Do not connect any power supply other than AC100V
      If the other power supply connected by accident, the inverter inside will burned out
        (2) Turn on the power switch
        (3) Lamp lights: the lamp light will stabilised after 15 to 20 minutes at the room temperature(20℃)
        (4) If the lamp does not lit, call for Service Office for the confirmation as described on other documents.
        (5) To suspend snaking of the lamp, press power switch 3 to 4 times [as ON/OFF].
      【3】 If the light does not lit
        Call for Service Office to confirm the following:
        (1) AC 100V supplied to the wall socket.
        (2) Plug the product into the wall socket.
        (3) Turn the power supply switch of the product ON
         
        Still the lamp does not lit: Consider the following:
         
        (1) Two of the viewer lamps lit simultaneously, one of the fuses of the inverters has blowouts.
        (2) Four of the viewer lamps does not light means that each of the fuses of the two inverters has blowouts.
         
      【Precautions】 The above occurs if the applied power supply is not AC 100V.
      Fuse bum out cause internal burnout of inverter. The burned inverter needs to replace.
      【4】 How to replace the lamp and keep it clean
        Place the Viewer on the flat table, and plug out the power supply cable from the wall socket.
      Remove the used device in the following order:
        (1) Unfasten the two of grub screws on the top frame.
        (2) To remove the top frame from the main unit;
      Holding 50 to 60 mm the grub screw of the top frame and press it forward.
        (3) Remove the glass plate and acrylic plate.
         
      【Precaution】 Glass plate easily breaks and may hurt your hands and fingers.
      Handle the edge of the plate with care not to scratch.
        ◆Replacing the lamps:
        (1) When the lamps used over 2,000 hours or one year, it needs to replace.
        (2) Remove the Lamp Tubes: Hold the edge of the Lamp Tubes, and turn it 90 degree.
        ◆Cleaning the device:
        (1) Impregnate alcohol to gauze then apply it onto the surface of the reflection plate / acrylic plate / glass surface to remove the dirt.
        (2) Clean the device once in six months to one year to keep quality of the Color Temperature and Luminance.
      【5】 Other Precautions
        Handling the viewer needs the following precautions because it contains the parts using glass.
        (1) Do not add strong impact on the viewer
        (2) Do not put any heavy items on the surface of the viewer
      DNP Standard Color Viewer for HDTV
      The DNP Standard color Viewer for HDTV is a light source which enables you to evaluate and adjust video and still cameras. With its high-frequency Fluorescent lighting method, it handles images without flicker.
      Specification
      Light source: DNP Standard color Viewer lamp
      (Four 15W dedicated fluorescent tubes are used)
      Power supply: AC100V 50、60Hz
      Lighting method: High Frequency lighting method 20KHz
      Color rendering: Over 90% rendering evaluation-point for each color
      Color temperature: (Measured by Minolta CL-200)
      Operating temperature: 10~40℃
      Operating humidity: Below 80%(avoid dew)
      Major diameter dimension: 490W×380H×150D m/m
      Luminance plane dimension: 272W×153H m/m
      Color chart dimension: 310W×200H m/m
      Power consumption: 110W
      Weight: 10kg
      photo
      HDF-51F
      The characteristics according to the Viewer Luminance plane
      Product Type Lamp Color Temperature Luminance Color matching shift
      HDF-51F FL15D-EDL-56K 5100K±300 Over 3500cd/m2 Within 5%
      *The specification may change without notice
      Operation Manual
      【1】 Before using the product:
        Power supply AC 100V, 50/60Hz shared
      Light source 15W DNP Standard color Viewer Lamp (4)
      Power consumption 110W
      【2】 Using the DNP Standard Color Viewer for HDTV
        (1) Plug the power cable of the product into AC100V
         
      【Precautions】 Do not connect any power supply other than AC100V
      If the other power supply connected by accident, the inverter inside will burned out
        (2) Turn on the power switch
        (3) Lamp lights: the lamp light will stabilised after 15 to 20 minutes at the room temperature(20℃)
        (4) If the lamp does not lit, call for Service Office for the confirmation as described on other documents.
        (5) To suspend snaking of the lamp, press power switch 3 to 4 times [as ON/OFF].
      【3】 If the light does not lit
        Call for Service Office to confirm the following:
        (1) AC 100V supplied to the wall socket.
        (2) Plug the product into the wall socket.
        (3) Turn the power supply switch of the product ON
         
        Still the lamp does not lit: Consider the following:
         
        (1) Two of the viewer lamps lit simultaneously, one of the fuses of the inverters has blowouts.
        (2) Four of the viewer lamps does not light means that each of the fuses of the two inverters has blowouts.
         
      【Precautions】 The above occurs if the applied power supply is not AC 100V.
      Fuse bum out cause internal burnout of inverter. The burned inverter needs to replace.
      【4】 How to replace the lamp and keep it clean
        Place the Viewer on the flat table, and plug out the power supply cable from the wall socket.
      Remove the used device in the following order:
        (1) Unfasten the four of grub screws on the top frame.
        (2) Pull up the upper frame.
        (3) Remove he glass plate and acrylic plate.
         
      【Precautions】 Glass plate easily breaks and may hurt your hands and fingers.
      Handle the edge of the plate with care not to scratch.
        ◆Replacing the lamps:
        (1) When the lamps used over 2,000 hours or one year, it needs to replace.
        (2) The socket of the lamp has a spring inside, press it toward one-way.
        ◆Cleaning the device:
        (1) Impregnate alcohol to gauze then apply it onto the surface of the reflection plate / acrylic plate / glass surface to remove the dirt.
        (2) Clean the device once in six months to one year to keep quality of the Color Temperature and Luminance.
      【5】 Other Precautions
        Handling the viewer needs the following precautions because it contains the parts using glass.
        (1) Do not add strong impact on the viewer
        (2) Do not put any heavy items on the surface of the viewer

      印刷看色臺(tái)

      印刷行業(yè)Z為常用的標(biāo)準(zhǔn)光源,符合 ISO 3664︰2009 行業(yè)照明

      DNP光源

      DNP透射式燈箱CCV-31F、CCV-51F 、HDCV-5000$

      標(biāo)準(zhǔn)光源對色箱P120,印刷光源箱比色箱

      標(biāo)準(zhǔn)光源對色燈箱參數(shù):$r$n$r$n配置:D65,TL84,CWF,

      會(huì)員登錄

      ×

      請輸入賬號

      請輸入密碼

      =

      請輸驗(yàn)證碼

      收藏該商鋪

      X
      該信息已收藏!
      標(biāo)簽:
      保存成功

      (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

      以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對此不承擔(dān)任何保證責(zé)任。

      溫馨提示:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

      在線留言