国产强伦姧在线观看无码,中文字幕99久久亚洲精品,国产精品乱码在线观看,色桃花亚洲天堂视频久久,日韩精品无码观看视频免费

      上海鼎徵儀器儀表設(shè)備有限公司

      免費(fèi)會(huì)員·7年
      您現(xiàn)在的位置: 上海鼎徵儀器儀表設(shè)備有限公司>>耐磨試驗(yàn)儀>>美國(guó)Electro-Magic>> FLTMBI107涂層附著力熱沖擊試驗(yàn)
      FLTMBI107涂層附著力熱沖擊試驗(yàn)
      參考價(jià): 面議
      具體成交價(jià)以合同協(xié)議為準(zhǔn)
      • 產(chǎn)品型號(hào)
      • 品牌
      • 代理商 廠商性質(zhì)
      • 上海市 所在地

      訪問(wèn)次數(shù):257更新時(shí)間:2022-04-26 10:18:25

      聯(lián)系我們時(shí)請(qǐng)說(shuō)明是智能制造網(wǎng)上看到的信息,謝謝!
      產(chǎn)品簡(jiǎn)介
      ApplicationThisprocedureisusedtodeterminetheresistancetocoatingadhesionlossofcoatedsurfacesofaluminum
      產(chǎn)品介紹






       

       

                                                         Application
      This procedure is used to determine the resistance to coating adhesion loss of coated surfaces of aluminum,plastic, steel, and other substrates when subjected to a wet blast similar to that produced by vehicle wash equipment.

       

       

                                 Apparatus and Materials Required
      Film Thickness Gauge
            per Ford Laboratory Test Method BI 117-01
      Carbide Tip Scribe
            CTS (General Scribe #CM 88) - or equivalent
           12015 Telegraph Rd.
           Detroit, Michigan U.S.A.
           (313) 531-7668
      Utility Knife
            Stanley, Quick Point 10-300 - or equivalent
           (break away tips)
      Water Immersion Tank
           Per Ford Laboratory Test Method BI 104-01
          Note:  Thermal shock testing requires:
              a.  38 +/- 2 °C water temperature
              b.  5 ppm maximum dissolved solids
      Heater/Circulator
             Fisher Scientific 13-874-70J - or equivalent
      Dissolved Solids Meter
            Myron L Company - or equivalent
            833 East Broadway
            San Gabriel, California
      Freezer
            Capable of minus 29 +/- 2 °C temperature 

      Steam Generator
         a.  Input flow of water to be 2.7 +/- .1 L/min (*).
         b.  Nozzle diameter to be 12.5 +/- .3 mm ID and at least 100 mm long.
         c.  Discharge dynamic head to be 37.9 +/- 1.9 kPa measured 25 mm from the nozzle  using 
      ??       a   4.7 mm ID tube. A substantially non-diverging discharge is required for this test (**) 
      ??    (***) (see Figures 1 and 2).
      Note:  Electro-Magic Model 100 (and the earlier Model 60) Steam Generator available only 
            from:Atomic Cleaning Systems, 31651 West Eight Mile Road, Livonia, MI 48150, Phone: 
      ??       (248) 615-4400, has been found to be satisfactory. The Model 100 or Model 60 are no 
      ??       longermanufactured directly by Electro-Magic. However, Atomic Cleaning Systems is
      ??       capable ofmodifying new Electro-Magic models to meet the Model 100 specifications
             required for this test.Milwaukee 1/2 inch globe valve No. 1151-1161, 150 SWP 300 WOg
      ??      is adequate for use in  standardization of generator.
      Model 100 Steam Generator
      (*)    The pumping pressure is directly related to the input flow rate. The pressure needed for
              therequired flow can be determined by measuring the pump pressure and discharge
              flow rate withthe burner off. When the burner is turned on, the required flow rate is
      ??        obtained by readjusting to the required pump pressure.
      (**)    This is done by placing the tube midstream 25 mm from the nozzle. The tube size must  
      ??         not bevaried because the densities and velocities are not uniform throughout the cross
      ??        section of thedischarge stream.
      (***)  Adjusting the discharge dynamic head may be required. This must be done in such a
            way thatthe input flow rate as specified in Para (a) above is maintained. This is done by
           adjusting the amount of heat transferred to the water. Increasing the heat will cause the
           flow rate (pressure) of (a) to change. It must be readjusted. This operation will result in an
      ??      increased dynamic pressure; to decrease it, decrease the heat and then adjust the flow
      ??    (pressure).

      Thermometer
      ??       Capable of measuring 100 +/- 2 °C
      Face Mask
            Full face cover safety mask is required when performing this test.
      Gloves
           Gauntlet-type gloves for protection of hands are required.


                                          Conditioning and Test Conditions
        All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 ??C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

                                                                Procedure
      1.  Standardize the Model 60 or Model 100 Steam Generator.
          a.  Measure and maintain the input flow at 2.7 L/min. Install a 12.5 mm globe valve in the
      ??        steam line between coil weld assembly and a 5/32 inch hose nipple. With burner off,
      ??         engage pump and adjust globe valve until 2.7 L/min is obtained.
              Record the tank pressure that is obtained with the 2.7 L/min flow rate. (This induced
               back pressure simulates the pressure that steam exerts on the system while the burner
               is on.)
         b.  Measure and maintain the mean dynamic head at 37.9 kPa (5.5 psi) using the fixtures as
             described in Figures 1 and 2. Open globe valve and turn on the burner. Allow tank
      ??       pressure   tostabilize before reading the mean dynamic head. Adjustments of the
             dynamic head are to be  made by changing the amount of heat transferred to the water
      ??       at the burner. (The flow  rate, as  specified above, must be maintained.)
          c.  Measure and maintain a 98 +/- 2 °C temperature of the steam blast at the test
      ??        sitedistance.

      2.    Measure film thickness per Ford Laboratory Test Method BI 117-01 at proposed test sites
           and record.
      3.  Immerse the parts or panels (previously prepared per Engineering Materials Specification)
      ??     in the water immersion tank for four hours at 38 +/- 2 °C. Aerate the water by placing 6.5
      ??     mm ID plastic tube at the bottom of the tank and bubble air at a rate of one bubble per
      ??     second minimum. Maintain a 5 ppm maximum dissolved solids (as NaCl) in the water.
      ??     Check and record NaCl level using a dissolved solids meter.
      4.  Remove the samples after four hours of water immersion and cut an "X" through the
      ??      coating into the substrate across the panel or part where feasible (see Figure 3).
            a.  Use a scribe to make the cut if the substrate is metal or hard, rigid plastic.
            b.  Use a utility knife to make the cut if substrate is an elastomeric material.
      5.  Place the test samples in a freezer at minus 29 +/- 2 °C for a three hour minimum freeze
          cycle.
      6.  Within 30 seconds from freezer removal, direct the steam blast at the center of the "X" cut,
      ??    at a distance  of 2 to 3 inches and 45° to the sample, in the direction shown in Figure 3.

       Note:  High pressure wet steam represents a potential safety hazard. Not only is it necessary|
                  to secure the samples properly, but full face protection and gloves are required.
      7.  After 30 seconds, record area (mm2) of coating removal by visually measuring with a
      ??      metric ruler  (typical triangular coating removal: Area = 1/2 Base x Height). Also examine
      ??      the surface and report  any blushing, whitening, or loss of gloss.
      8. If a failure occurs, note number of seconds after steam black initiated that the failure 
            occurred.


      Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly.
      Each party is responsible for determining proper use and handling in its facilities.
                                                           ATTACHMENT ONE
                                                            RATING SCALE FOR
                                                   THERMAL SHOCK TEST PANELS

                                                          RATING               PEEL BACK
                                                                  20      =       No removal
                                                                  19      =       < 0.5 cm^2
                                                                  18      =       < 1.0 cm^2
                                                                  17      =       < 1.5 cm^2
                                                                  16      =       < 2.0 cm^2
                                                                  15      =       < 2.5 cm^2
                                                                  14      =       < 3.0 cm^2
                                                                  13      =        < 3.5 cm^2
                                                                  12      =        < 4.0 cm^2
                                                                  11      =        < 4.5 cm^2
                                                                  10      =        < 5.0 cm^2
                                                                   9       =         < 5.5 cm^2
                                                                   8       =         < 6.0 cm^2
                                                                   7       =         < 6.5 cm^2
                                                                   6       =         < 7.0 cm^2
                                                                   5       =         < 7.5 cm^2
                                                                   4       =         < 8.0 cm^2
                                                                   3       =         < 8.5 cm^2
                                                                   2       =         < 9.0 cm^2
                                                                   1       =         < 9.5 cm^2
                                                                   0       =          > 9.5 cm^2
                                        SEE SPECIFICATION FOR ACCEPTANCE CRITERIA RATING

       



                                                              Figure 1


       

                                                               Figure 2

       

                                                                       Figure 3



                                                          Figure 4



      會(huì)員登錄

      ×

      請(qǐng)輸入賬號(hào)

      請(qǐng)輸入密碼

      =

      請(qǐng)輸驗(yàn)證碼

      收藏該商鋪

      X
      該信息已收藏!
      標(biāo)簽:
      保存成功

      (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
      產(chǎn)品對(duì)比 二維碼

      掃一掃訪問(wèn)手機(jī)商鋪

      對(duì)比框

      在線留言