      VersatileDataLoaderTheDL615turnsanyMicrosoftWindowsPCintoanARINC615-3andARINC603dataloader
    1. Versatile Data Loader

      The DL 615 turns any Microsoft Windows PC into an 

      ARINC 615-3 and ARINC 603 data loader.

      Applications

      · Flightline support

      · Avionics development and testing

      · Aircraft maintenance

      · System upgrades

        ARINC 429 databus to USB interface  



       

      Key Features

      · Replaces old 3-inch floppy disk only PDLs

      · Use with any MS Windows廬 compatible PC

      · ARINC 615-3 and 603 protocols

      · Load from floppy, HD, USB, CD, DVD, or network

      · Clear indicators for load progress and status

      · Efficient multi-file, multi-disk and extra-large loads

      · Numerous logging options

      · Protocol recording and diagnostic tools

      · Configurable for problematic LRUs


      Portable ARINC 615 Data Loaders_dl615.jpg

      The DL 615 is the modern replacement for outmoded 3-inch floppy disk only ARINC 615 portable data loaders (PDL). Any PC running Microsoft廬 Windows廬 can perform data loads using the USB to ARINC 429 interface, cables, and software included with the DL 615. While being as simple to use as older floppy disk PDLs, the DL 615 provides record keeping, flexibility in data management, and powerful features for troubleshooting and enabling data loads into difficult LRUs. As an added benefit, the interface can be used as a general purpose ARINC 429 (and optionally ARINC 717) maintenance tool.

      The DL 615 provides flexibility in how data to be loaded is stored and managed. Data can be loaded from floppy disks, hard disk, USB device, CD, DVD, and even from wired or wireless network locations. The transfer status display shows exactly how the load is progressing. Some LRUs have non-standard timing and can be difficult to load. The DL 615 provides compliant, tolerant, and custom timing options which, along with the included 615 protocol recording and debugging/diagnostic tools, enable the DL 615 to load LRUs that are impossible to load with other loaders.

      Benefits

      · Intuitive operation

      · Lightweight, portable and durable

      · Modern solution

      · Obsolescence proof

      · Powered by PC over USB

      · Use with any available PC

      · Integrates with other applications

      · Multipurpose loader/maintenance tool                                    s_dl615-screen.jpg

      What's Included

      All DL 615 models include the following items:

      · Data loading software (MS Windows)

      · ARINC 429 databus to USB interface
      (also available with ARINC 717)

      · 53-pin data loader cable

      · 53-pin to 31-pin adapter cable (ARINC 603)

      · Locking USB cable

      Rugged carrying case


      USB Interface Peripheral

      · ARINC 429 protocol

      · 8 receive, 4 transmit channels standard (other channel counts available)

      · Discrete I/O: 8 channels

      Computer Interface

      · USB 2.0

      Cables Included

      · 53-pin data loader cable, 10 ft (3m)

      · 53-pin to 31-pin adapter cable (ARINC 603), 1 ft (0.3m)

      · Locking USB cable, 5 ft (1.5m)

      聽(tīng)

      Power

      · Single USB port

      Temperature Range

      · Component: -40 to +85 deg C

      · Storage: -55 to +100 deg C

      Dimensions

      · USB Interface Peripheral: 3.0 x 4.45 x 0.97 in (76 x 113 x 25 mm)

      · Carrying Case: 16.0 x 13.0 x 6.9 in (407 x 330 x 175 mm)

      Using DL 615 Hardware for Databus Test (CoPilot)

      The DL 615 includes one of Ballard's pocket-sized USB 429 databus interfaces. These interfaces provide a high level of ARINC 429 (and optionally ARINC 717) functionality.

      By adding Ballard's CoPilot廬 graphical test and simulation software, the DL 615 becomes a highly-effective tool for databus analysis, test, and simulation. CoPilot can be added at any time. However, a discount applies when CoPilot is purchased in a bundle with the DL 615.

      The 'Ordering' tab shows part numbers for the CoPilot bundle, and various protocol and channel options.

      Get More Information

      Click the links below to get more details and specifications:

      · USB 429/717 Interfaces

      · CoPilot Software

      Software Operating System Requirements

      The Data Loader Software requires the Microsoft® Windows® XP Operating System or above. This includes Windows XP, Windows Server 2003, Windows Vista, Windows Server 2008, Windows 7, and Windows 8.

      Suggested Hardware System Requirements

      · Intel® Core™2 Duo, 2 GHz (multi-core) processor or higher

      · 4 GB RAM

      · 2 GB of available hard disk space (additional free disk space required for data logging)

      · USB Host Port, 2.0 or higher

      Minimum Hardware System Requirements

      · 1 GHz 32-bit (x86) or 64-bit (x64) processor

      · 2 GB RAM

      · 1 GB of available hard disk space

      · USB 2.0 Host Port

      Trademarks are the property of their respective owners.


      Software Licensing Overview

      The Data Loader software license is designed to provide maximum flexibility. There are no dongles to lose or expensive site licenses to manage, just a simple software "key" embedded in the Ballard databus interface hardware. The Data Loader software can be freely installed on as many computers as desired. Any of these computers are authorized to operate the interface hardware containing the license key.

      Standard Data Loader Kit

      Part No.

      Description

      DL-UA1430-01

      Standard data loader kit
      with ARINC 429, 8R4T channels

      Other Data Loader Kits

      Other DL 615 data loader kits are available with various channel counts, ARINC 717, and CoPilot software—useful when using the interface hardware for databus test:

      Part No.

      Databus Channels

      DL 615
      Kit Only

      DL 615
      & CoPilot*

      ARINC 429

      ARINC 717

      DL-UA1440-01

      DL-UA1440-02

      12R4T

      -

      DL-UA1430-01

      DL-UA1430-02

      8R4T

      -

      DL-UA1420-01

      DL-UA1420-02

      4R2T

      -

      DL-UA1431-01

      DL-UA1431-02

      8R4T

      2R2T

      *Includes CoPilot analysis & test software (see 'Databus Test' tab for more details)

      nRnT = number of Receive/Transmit channels

      The interface hardware is black, for optional Flight Test Orange color add '/FTO' suffix to the above part number.
         Example: DL-UA1430-01/FTO

      What's Included

      All DL 615 models include the following items:

      · Data loading software (MS Windows)

      · ARINC 429 databus to USB interface
      (also available with ARINC 717)

      · 53-pin data loader cable

      · 53-pin to 31-pin adapter cable (ARINC 603)

      · Locking USB cable

      · Rugged carrying case

      Data Loader Components

      The Data Loader software and cables are available separately for use with previously purchased interface hardware or for replacement.

      Part No.

      Description

      SW-615-DL

      Data loader software; for use with Ballard BTIDriver compatible interface hardware

      16080

      53-pin data loader cable

      16081

      53-pin to 31-pin adapter cable (ARINC 603)


    2. 會(huì)員登錄

      ×

      請(qǐng)輸入賬號(hào)

      請(qǐng)輸入密碼

      =

      請(qǐng)輸驗(yàn)證碼

      收藏該商鋪

      X
      該信息已收藏!
      標(biāo)簽:
      保存成功

      (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
      在線留言