參考價(jià): | 面議 |
- 產(chǎn)品型號(hào)
- 品牌
- 經(jīng)銷商 廠商性質(zhì)
- 上海市 所在地
訪問(wèn)次數(shù):312更新時(shí)間:2017-10-30 21:12:57
西門子6ES74317KF100AB0 西門子6ES74317KF100AB0
![]() | 6ES7431-7KF10-0AB0 SIMATIC S7-400,模擬量輸入SM 431,8AI;16 位分辨率,RESIST./PT100/NI100,光隔離,診斷 ,報(bào)警,20 MS模塊升級(jí) |
公司名稱:上海朔川電氣設(shè)備有限公司
聯(lián) 系 人:吉夢(mèng)琪
:
地址:上海市金山區(qū)涇波路129號(hào)
:2840735331
信譽(yù)*,客戶*是公司成立之初所確立的宗旨,在公司的嚴(yán)格要求和員工們不折不扣地貫徹執(zhí)行下發(fā)展延續(xù)至今。“假一罰十”一直是我公司的主動(dòng)承諾。
承諾一:1、保證全新*
承諾二:2、保證安全準(zhǔn)時(shí)發(fā)貨
承諾三:3、保證售后服務(wù)質(zhì)量
流程一:1、客戶確認(rèn)所需采購(gòu)產(chǎn)品型號(hào)
流程二:2、我方會(huì)根據(jù)詢價(jià)單型號(hào)查詢價(jià)格以及交貨期,擬一份詳細(xì)正規(guī)報(bào)價(jià)單
流程三:3,客戶收到報(bào)價(jià)單并確認(rèn)型號(hào)無(wú)誤后訂購(gòu)產(chǎn)品
流程四:4、報(bào)價(jià)單負(fù)責(zé)人根據(jù)客戶提供型號(hào)以及數(shù)量擬份銷售合同
流程五:5、客戶收到合同查閱同意后蓋章回傳并按照合同銷售額匯款到公司開(kāi)戶行
流程六:6、我公司財(cái)務(wù)查到款后,業(yè)務(wù)員安排發(fā)貨并通知客戶跟蹤運(yùn)單
您隨口的一問(wèn)多少錢,我就立馬放下筷子趕緊回話。
您隨口的一句有沒(méi)有現(xiàn)貨,我就立馬進(jìn)去系統(tǒng)拼命地找。
您隨口問(wèn)了問(wèn)能優(yōu)惠不?我就到處想辦法。
您很隨便,我卻很當(dāng)真;您不知道我的回答,只為得到您的滿意..……
只因?yàn)槲液湍恢故强蛻舻年P(guān)系,而是把您當(dāng)我的朋友,在全力以赴做到我能做到的
您的選擇您的支持是我zui大的動(dòng)力! ————致我親愛(ài)的客戶(好朋友)
產(chǎn)品簡(jiǎn)述:質(zhì)保一年,一年內(nèi)因產(chǎn)品質(zhì)量問(wèn)題免費(fèi)更新產(chǎn)品不收取任何費(fèi)用
哪里有賣 要多少錢 哪里有 哪里能買到 要在哪里買 在哪里有賣的 價(jià)格,參數(shù),型號(hào),哪家便宜,比較便宜,哪里有,銷售,訂貨號(hào),多少錢?哪家價(jià)格好? 廠家,性能,優(yōu)點(diǎn),包裝,用途,售后服務(wù)!哪里有賣 代理商 總代理商
![]() | 6ES7431-7KF10-0AB0 SIMATIC S7-400,模擬量輸入SM 431,8AI;16 位分辨率,RESIST./PT100/NI100,光隔離,診斷 ,報(bào)警,20 MS模塊升級(jí) |
SM 431 模擬量輸入模塊
- 訂貨數(shù)據(jù)
- 附件
- 產(chǎn)品信息
- 組態(tài)工具
跳轉(zhuǎn)到
概述
應(yīng)用
設(shè)計(jì)
功能
技術(shù)規(guī)范
更多信息
概述
- 用于SIMATIC S70-400 的模擬量輸入
- 用于連接電壓和電流傳感器、熱電耦、電阻和熱電阻
- 分辨率為 13 到 16 位
應(yīng)用
模擬量輸入模板用來(lái)實(shí)現(xiàn)PLC與模擬量過(guò)程信號(hào)的連接。 用于連接電壓和電流傳感器、熱電耦、電阻和熱電阻
設(shè)計(jì)
模擬量輸入模塊具有以下機(jī)械特點(diǎn):
- 設(shè)計(jì)緊湊:
堅(jiān)固的塑料機(jī)殼里包括:- 前連接器插槽
- 標(biāo)簽條
- 安裝簡(jiǎn)單
- 用戶友好的接線:
通過(guò)插入式前連接器來(lái)對(duì)模塊接線。
功能
模擬量輸入模板將過(guò)程模擬量信號(hào)轉(zhuǎn)換成S7-400內(nèi)部處理所需的數(shù)字量值。
該模塊具有以下特性:
- 分辨率為 13 到 16 位
- 不同的量程
- 報(bào)警功能
- 診斷
技術(shù)規(guī)范
Article number | 6ES7431-0HH00-0AB0 | 6ES7431-1KF20-0AB0 | 6ES7431-1KF00-0AB0 | 6ES7431-1KF10-0AB0 | |
---|---|---|---|---|---|
| SIMATIC S7-400, ANALOG INPUT | SIMATIC S7-400, SM 431 | SIMATIC S7-400, SM 431 | SIMATIC S7-400, SM 431 | |
Supply voltage |
|
|
|
| |
Load voltage L+ |
|
|
|
| |
| 24 V; Only required for supplying 2-wire transmitters | 24 V; Only required for supplying 2-wire transmitters | not necessary | 24 V; Only required for supplying 2-wire transmitters | |
| Yes | Yes |
| Yes | |
Input current |
|
|
|
| |
from load voltage L+ (without load), max. | 400 mA; for 16 connected, fully controlled 2-wire transmitters | 200 mA; for 8 connected, fully controlled 2-wire transmitters |
| 200 mA; for 8 connected, fully controlled 2-wire transmitters | |
from backplane bus 5 V DC, max. | 100 mA | 1 000 mA | 350 mA | 600 mA | |
Power loss |
|
|
|
| |
Power loss, typ. | 2 W | 4.9 W | 1.8 W | 3.5 W | |
Analog inputs |
|
|
|
| |
Number of analog inputs | 16 | 8 | 8 | 8 | |
| 16 | 8 | 8 | 8 | |
|
| 4 | 4 | 4 | |
permissible input voltage for voltage input (destruction limit), max. | 20 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20) | 18 V; 18 V continuous, 75 V for 1 ms (mark to space ratio 1:20) | 50 V | 18 V; 18 V continuous, 75 V for 1 ms (mark to space ratio 1:20) | |
permissible input current for current input (destruction limit), max. | 40 mA | 40 mA; Permanent | 50 mA; 40 mA continuous | 40 mA; Permanent | |
Input ranges |
|
|
|
| |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
| No | No | No | Yes | |
| No | No | No | Yes | |
| No | Yes | Yes | Yes | |
Input ranges (rated values), voltages |
|
|
|
| |
| Yes | Yes | Yes | Yes | |
| 100 k? | 10 M? | 200 k? | 1 M? | |
| Yes | Yes | Yes | Yes | |
| 10 M? | 10 M? | 200 k? | 1 M? | |
| Yes | Yes | Yes | Yes | |
| 100 k? | 100 k? | 200 k? | 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
Input ranges (rated values), currents |
|
|
|
| |
|
|
|
| Yes | |
|
|
|
| 50 ? | |
| Yes | Yes | Yes |
| |
| 50 ? | 50 ? | 80 ? |
| |
| Yes | Yes | Yes | Yes | |
| 50 ? | 50 k? | 80 ? | 50 ? | |
Input ranges (rated values), thermocouples |
|
|
|
| |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
Input ranges (rated values), resistance thermometer |
|
|
|
| |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
Input ranges (rated values), resistors |
|
|
|
| |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
|
|
| Yes | |
|
|
|
| 1 M? | |
|
| Yes | Yes | Yes | |
|
|
| usable up to 500 ohms | 1 M? | |
|
|
|
| Yes; Usable up to 5000 Ohm | |
|
|
|
| 1 M? | |
Thermocouple (TC) |
|
|
|
| |
Temperature compensation |
|
|
|
| |
|
|
|
| No | |
|
|
|
| Yes | |
|
|
|
| Yes | |
|
|
|
| Yes | |
Characteristic linearization |
|
|
|
| |
|
|
|
| Yes | |
|
|
|
| Type B, E, J, K, L, N, R, S, T, U | |
|
|
|
| Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000 | |
Cable length |
|
|
|
| |
| 200 m | 200 m | 200 m | 200 m; 50 m with thermocouples and input ranges <= 80 mV | |
Analog value generation for the inputs |
|
|
|
| |
Integration and conversion time/resolution per channel |
|
|
|
| |
| 13 bit | 14 bit; 14 / 14 / 14 | 13 bit | 14 bit; with activated filtering: 16 bits | |
| Yes | Yes | Yes | Yes | |
| 55 / 65 ms | 52 µs | 23 / 25 ms | 20.1 / 23.5 ms | |
| 50 / 60 ms |
| 16,7 / 20 ms | 16,7 / 20 ms | |
|
|
|
|
| |
|
|
|
| 4,3 ms | |
|
|
|
| 40.2 / 47 ms | |
|
|
|
| 5,5 ms | |
| 50 / 60 Hz | none / 400 / 60 / 50 Hz | 50 / 60 Hz | 50 / 60 Hz | |
Encoder |
|
|
|
| |
Connection of signal encoders |
|
|
|
| |
| Yes; possible | Yes; possible | Yes; possible | Yes; possible | |
|
| Yes | Yes; with external transmitter supply | Yes | |
| Yes | Yes | Yes | Yes | |
|
| Yes; Line resistances are also measured | Yes; Line resistances are also measured | Yes; Line resistances are also measured | |
|
| Yes; Line resistances are also measured | Yes; Line resistances are also measured | Yes | |
|
| Yes | Yes | Yes | |
Errors/accuracies |
|
|
|
| |
Operational error limit in overall temperature range |
|
|
|
| |
| 0.65 %; 1.0 % at 1 to 5 V; 0.65 % at ±1 V, ±10 V | 0.7 %; ±0.7 % at ±1 V; ±0.9 % at ±10 V, 1 to 5 V | 1 %; ±1.0 % at ±1 V; ±0.6 % at ±10 V; ±0.7 % at 1 to 5 V | 0.38 %; ±0.38 % at ±80 mV; ±0.35 % at ±250 mV, ±500 mV, ±1 V, ±2,5 V, ±5 V, 1 to 5 V, ±10 V | |
| 0.65 % | 0.8 %; at ±20 mA, 4 to 20 mA | 1 %; at ±20 mA, 4 to 20 mA | 0.35 %; ±20 mA, 0 to 20 mA, 4 to 20 mA | |
|
| 1 % | 1.25 %; 0 to 500 ohms (4-conductor measurement, in range of 600 ohms) | 0.5 % | |
|
|
|
| 0.5 % | |
Basic error limit (operational limit at 25 °C) |
|
|
|
| |
| 0.25 %; 0.5% at 1 to 5 V; 0.25% at ±1 V, ±10 V | 0.6 %; 0.6 % at ±1 V; 0.75 % at ±10 V, 1 to 5 V | 0.7 %; 0.7% at ±1 V; 0.4% at ±10 V; 0.5% at 1 to 5 V | 0.15 %; ±0.15 % (±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, 1 to 5 V, ±10 V); ±0.17% (±80 mV) | |
| 0.25 %; at ±20 mA, 4 to 20 mA | 0.7 %; at ±20 mA, 4 to 20 mA | 0.7 %; at ±20 mA, 4 to 20 mA | 0.15 %; ±20 mA, 0 to 20 mA, 4 to 20 mA | |
|
| 0.7 %; 0 to 600 ohms | 0.8 %; 0 to 500 ohms (4-conductor measurement, in range of 600 ohms) | 0.15 %; ±0.15 % at 0 to 48 ohms (4-conductor measurement), 0 to 150 ohms (4-conductor measurement), 0 to 300 ohms (4-conductor measurement), 0 to 600 ohms (4-conductor measurement), 0 to 5000 ohms (4-conductor measurement, in range of 6000 ohms); ±0.3 % at 0 to 300 ohms (3-conductor measurement), 0 to 600 ohms (3-conductor measurement), 0 to 5000 ohms (3-conductor measurement, in range of 6000 ohms) | |
|
|
|
| 0.3 % | |
Potential separation |
|
|
|
| |
Potential separation analog inputs |
|
|
|
| |
| No | Yes; internal/external | Yes; internal/external | Yes; internal/external | |
| No | No | No | No | |
Isolation |
|
|
|
| |
Isolation tested with | 500 V AC/707 V DC, type test | 2 120 V DC between bus and analog section; 500 V DC between bus and local ground; 500 V DC between analog part and L+/M; 2 120 V DC between analog part and local ground; 2 120 V DC between L+/M and local ground | 2120 V DC between bus and analog part; 500 V DC between bus and local ground; 2120 V DC between analog part and local ground | 2 120 V DC between bus and L+/M; 2 120 V DC between bus and analog section; 500 V DC between bus and local ground; 500 V DC between analog section and L+/M; 2 120 V DC between analog section and local ground; 2 120 V DC between L+/M and local ground | |
Dimensions |
|
|
|
| |
Width | 25 mm | 25 mm | 25 mm | 25 mm | |
Height | 290 mm | 290 mm | 290 mm | 290 mm | |
Depth | 210 mm | 210 mm | 210 mm | 210 mm | |
Weights |
|
|
|
| |
Weight, approx. | 500 g | 500 g | 500 g | 500 g |
Article number | 6ES7431-7QH00-0AB0 | 6ES7431-7KF00-0AB0 | 6ES7431-7KF10-0AB0 | |
---|---|---|---|---|
| SIMATIC S7-400, SM 431 | SM 431, 8AI, U/I/THERMO, 16BIT | SM 431, 8AI, RESIST./PT100, 16BIT, | |
Supply voltage |
|
|
| |
Load voltage L+ |
|
|
| |
| 24 V; Only required for supplying 2-wire transmitters |
|
| |
| Yes |
|
| |
Input current |
|
|
| |
from load voltage L+ (without load), max. | 400 mA; for 16 connected, fully controlled 2-wire transmitters |
|
| |
from backplane bus 5 V DC, max. | 700 mA | 1 200 mA | 650 mA | |
Power loss |
|
|
| |
Power loss, typ. | 4.5 W | 4.6 W | 3.3 W | |
Analog inputs |
|
|
| |
Number of analog inputs | 16 | 8 | 8 | |
| 16 | 8 |
| |
| 8 |
| 8 | |
permissible input voltage for voltage input (destruction limit), max. | 18 V; 18 V continuous, 75 V for 1 ms (mark to space ratio 1:20) | 35 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20) | 35 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20) | |
permissible input current for current input (destruction limit), max. | 40 mA | 32 mA |
| |
Input ranges |
|
|
| |
| Yes | Yes | No | |
| Yes | Yes | No | |
| Yes | Yes | No | |
| Yes | No | Yes | |
| Yes | No | Yes | |
Input ranges (rated values), voltages |
|
|
| |
| Yes | Yes |
| |
| 1 M? | > 2 000 ohms |
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
|
| Yes |
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
|
| Yes |
| |
| Yes |
|
| |
| 1 M? |
|
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
| Yes | Yes |
| |
| 1 M? |
|
| |
Input ranges (rated values), currents |
|
|
| |
| Yes | Yes |
| |
| 50 ? |
|
| |
| Yes | Yes |
| |
| 50 ? |
|
| |
| Yes | Yes |
| |
| 50 ? |
|
| |
|
| Yes |
| |
| Yes | Yes |
| |
| 50 ? | 50 ? |
| |
| Yes | Yes |
| |
| 50 ? |
|
| |
Input ranges (rated values), thermocouples |
|
|
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
| Yes | Yes |
| |
Input ranges (rated values), resistance thermometer |
|
|
| |
| Yes |
| Yes | |
| 1 M? |
| > 10 000 ohms | |
| Yes |
| Yes; Different characteristics selectable: Europe/U.S. | |
| 1 M? |
| > 10 000 ohms | |
| Yes |
| Yes | |
| 1 M? |
| > 10 000 ohms | |
| Yes |
| Yes | |
| 1 M? |
| > 10 000 ohms | |
| Yes |
| Yes | |
| 1 M? |
| > 10 000 ohms | |
| Yes |
| Yes | |
| 1 M? |
| > 10 000 ohms | |
Input ranges (rated values), resistors |
|
|
| |
| Yes |
|
| |
| 1 M? |
|
| |
| Yes |
|
| |
| 1 M? |
|
| |
| Yes |
|
| |
| 1 M? |
|
| |
| Yes |
|
| |
| 1 M? |
|
| |
| Yes; Usable up to 5000 Ohm |
|
| |
| 1 M? |
|
| |
Thermocouple (TC) |
|
|
| |
Temperature compensation |
|
|
| |
|
| Yes |
| |
| Yes | Yes |
| |
| Yes |
|
| |
| Yes | Yes |
| |
Characteristic linearization |
|
|
| |
| Yes | Yes | Yes | |
| Type B, E, J, K, L, N, R, S, T, U | Type B, E, J, K, L, N, R, S, T, U |
| |
| Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000 |
| Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000; different characteristics selectable (Europe/U.S.) | |
Cable length |
|
|
| |
| 200 m; 50 m with thermocouples and input ranges <= 80 mV | 200 m | 200 m; 50 m with thermocouples and input ranges ±80 mV | |
Analog value generation for the inputs |
|
|
| |
Integration and conversion time/resolution per channel |
|
|
| |
| 16 bit; 16 / 16 / 16 | 16 bit | 16 bit | |
| Yes | Yes | Yes | |
| 6 / 20,1 / 23,5 ms | 10 / 16,7 / 20 / 100 | 8 / 23 / 25 ms | |
| 2,5 / 16,7 / 20 ms | 2,5 / 16,7 / 20 / 100 | 20 ms at 50 Hz (entire module incl. wire break) | |
|
|
|
| |
| 4.3 / 4.3 / 4.3 ms |
| 110 ms / 4 ms | |
| 12 / 40,2 / 47 ms |
|
| |
| 5,5 ms | 1 ms (module) | none | |
| 400 / 60 / 50 Hz | 400 / 60 / 50 / 10 Hz | none/ 60 / 50 Hz | |
Encoder |
|
|
| |
Connection of signal encoders |
|
|
| |
| Yes; possible | Yes; possible |
| |
| Yes |
|
| |
| Yes | Yes |
| |
| Yes; Line resistances are also measured |
|
| |
| Yes |
| Yes | |
| Yes | Yes | Yes | |
Errors/accuracies |
|
|
| |
Operational error limit in overall temperature range |
|
|
| |
| 0.3 %; ±0.3 % at ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, 1 to 5 V, ±10 V; ±0.31 % at ±80 mV; ±0.32 % at ±50 mV; ±0.35 % at ±25 mV | 0.3 % |
| |
| 0.3 %; at 0 to 20 mA, ±5 mA, ±10 mA, ±20 mA, 4 to 20 mA | 0.5 % |
| |
| 0.3 %; ±0.3% at 0 to 48 Ohm (4-conductor measurement), 0 to 150 Ohm (4-conductor measurement), 0 to 300 Ohm (4-conductor measurement), 0 to 600 Ohm (4-conductor measurement), 0 to 5000 Ohm (4-conductor measurement, in range of 6000 Ohm); ±0.4% at 0 to 300 Ohm (3-conductor measurement), 0 to 600 Ohm (3-conductor measurement), 0 to 5000 Ohm (3-conductor measurement, in range of 6000 Ohm); |
|
| |
| 0.4 % |
| ±1 °C | |
Basic error limit (operational limit at 25 °C) |
|
|
| |
| 0.15 %; ±0.15% at ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, 1 V to 5 V, ±10 V; ±0.17% at ±80 mV; ±0.19% at ±50 mV; ±0.23% at ±25 mV | 0.1 % |
| |
| 0.15 %; at 0 to 20 mA, ±5 mA, ±10 mA, ±20 mA, 4 to 20 mA | 0.17 % |
| |
| 0.15 %; ±0.15 % at 0 to 48 ohms (4-conductor measurement), 0 to 150 ohms (4-conductor measurement), 0 to 300 ohms (4-conductor measurement), 0 to 5000 ohms (4-conductor measurement, in range of 6000 ohms); ±0.3 % at 0 to 300 ohms (3-conductor measurement), 0 to 600 ohms (3-conductor measurement), 0 to 5000 ohms (3-conductor measurement, in range of 6000 ohms) |
|
| |
| 0.3 % |
| ±0,2 °C | |
Interrupts/diagnostics/status information |
|
|
| |
Alarms |
|
|
| |
| Yes; Parameterizable | Yes; Parameterizable | Yes; Parameterizable | |
| Yes; Parameterizable | Yes | Yes | |
Potential separation |
|
|
| |
Potential separation analog inputs |
|
|
| |
| Yes; internal/external | Yes; internal/external | Yes; internal/external | |
| No | Yes | No | |
Isolation |
|
|
| |
Isolation tested with | 2 120 V DC between bus and L+/M; 2 120 V DC between bus and analog section; 500 V DC between bus and local ground; 500 V DC between analog section and L+/M; 2 120 V DC between analog section and local ground; 2 120 V DC between L+/M and local ground | 1500 V DC | 1500 V DC | |
Dimensions |
|
|
| |
Width | 25 mm | 25 mm | 25 mm | |
Height | 290 mm | 290 mm | 290 mm | |
Depth | 210 mm | 210 mm | 210 mm | |
Weights |
|
|
| |
Weight, approx. | 500 g | 650 g | 650 g |