GIVE MISUREPBS-HR 5Z 00320 05VL M06/S SC ZERO光柵尺
參考價(jià): | 面議 |
- 意大利 產(chǎn)品型號(hào)
- 品牌
- 其他 廠商性質(zhì)
- 上海市 所在地
訪問(wèn)次數(shù):1418更新時(shí)間:2016-02-13 11:22:19
Givi Misure P89 06052099 05565 光柵尺 Givi Misure P89 06052099 05565 光柵尺
KOBOLD DRS-0150G4K0000 流量計(jì)
KOBOLD TMA-06416205 流量計(jì)
KOBOLD NKP-6401/3 液位計(jì)
Givi Misure P89 06052099 05565 光柵尺 KOBOLD MAN-RD71/B9 壓力表
KOBOLD NSP-SW04TPK 流量計(jì)
KOBOLD TGL-5126C100G C DIN 16186 G-1/2 L=100 0-160℃ 溫度計(jì)
Givi Misure P89 06052099 05565 光柵尺 KOBOLD PSR-11153R15R1 流量計(jì)KOBOLD DRS-0150G4K0000 流量計(jì)
KOBOLD PSR-11206R20R1 流量計(jì)
KOBOLD MAS-5100 流量計(jì)配件
KOBOLD Messring GmbH TIR-SS4T8C 650-1800℃ 溫度傳感器
KOBOLD Messring GmbH VKM-3202R0R080R 流量傳感器
KOBOLD Messring GmbH VKM3102R0R080B 流量傳感器
KOBOLD Messring GmbH 3251.073.002 壓力傳感器KOBOLD DRS-0150G4K0000 流量計(jì)
channels.
Output Range Resolution Accuracy (% span)
0 to 1mA 0.554% ±2.0% (±0.002mA)
0 to 20mA 0.028% ±0.1% (±0.02mA)
4 to 20mA 0.035% ±0.1% (±0.02mA)
Maximum Output Current
22.5mA DC typical.
Integral Non-Linearity
±0.1% of span or ±2 LSB typical, whichever is larger,
for spans equal to or greater than 16mA.
Output Compliance
12V minimum, 12.7V typical.
Output Load Resistance Range
0 to 630 ohms typical.
Response Time
11ms typical into 500 ohms, for measurement to
reach 98% of the final value in response to a step
command. Actual response time will vary with load.
I Voltage Output (918MB)
DC Voltage Output Ranges
Range user-configured. Selection applies to all channels.
Output Range Resolution Accuracy (% span)
0 to 1V 0.274% ±0.6% (±6mV)
0 to 5V 0.055% ±0.1% (±5mV)
0 to 10V 0.027% ±0.1% (±10mV)
Maximum Output Voltage
11.255V DC typical.
Integral Non-Linearity
±0.1% of span or ±2 LSB typical, whichever is larger,
for spans equal to or greater than 5V.
Output Current
0 to 10mA DC maximum.
Output Impedance
1 ohm.
Output Short Circuit Protection
Included.
Response Time
110μs rise time typical, 150μs fall time typical,
unloaded, for output to reach 98% of the final value
in response to a step command. Time varies with load.
I Discrete Output
Output Type
Four independent open drain MOSFET switches with a
common return that operate as low-side switches.
Output Voltage Range
0 to 35V DC (up to 1A/channel continuous).
External voltage source required.
Output ON Resistance
0.15 ohms maximum.
Operation
Digital outputs are set to their OFF state following a
software or power-on reset. Outputs may be set to
user-defined states following a watchdog timeout.
Watchdog timeout output control takes precedence
over limit alarm control. Alarm control takes prece-
dence over host control.
Output Response Time
4.1ms typical, from receipt of command to gate
transition of the output MOSFET.
I Communication
Supported Modbus Commands
The command/response protocol for communicating
with this module adheres to the Modbus/RTU standard
for the following Modbus Functions.
Read Coil (Output) Status Report Slave ID
Read Holding Registers Reset Slave
Read Input Registers
Force Single Coil (Output)
Preset Single Register
Force Multiple Coils (Output)
Preset Multiple Registers
LED Indicators
LEDs indicate power, status, and discrete level/alarm.
I Power and Isolation
Power Requirements
10 to 36V DC (918MB), 12 to 36V DC (917MB)
22 to 26V AC.
Supply Current
Supply Current Draw (917) Current Draw (918)
10V DC Not Recommended 100mA maximum
12V DC 275mA maximum 85mA maximum
24V DC 120mA maximum 45mA maximum
24V AC 210mA rms max. 85mA rms max.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between outputs, network, and power
circuits.
I Ordering
Information
Models
917MB-0900
918MB-0900
DC current (917MB) or voltage (918MB) output module
Accessories
900C-SIP
Configuration Software Interface Package
(includes software CD-ROM for Windows, RS-232/485
converter, and RS-485/three-wire cable)
4001-095
USB-to-RS232 adapter. See page 70 for more info.
TBK-B02
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S02
Optional terminal block kit, spring clamp style, 4 pcs.
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
For more information on software, network hardware,
and mounting accessories, please see Pages 69-71.
DC CURRENT OUTPUT
ANALOG OUTPUT
CONNECTIONS
DIGITAL OUTPUTS
45 46
TB4
OUT3
RTN
DIGITAL OUTPUT
TB4
RTN
OUT2
OUT1
44 43 42 36 41
TB3
OUT0
D
COM
COM
D
RS485
33 34 35 31 32
A
B
PWR
TB3
TB1
ANALOG?
OUTPUT
ANALOG?
OUTPUT
TB2
AC/DC?
POWER
NETWORK?
COMMUNICATION
DC VOLTAGE OUTPUT
TB1
I0+
RTN
12 11
ANALOG OUTPUTS
13
RTN
I1+
RTN
14 15
ANALOG OUTPUTS
16
RTN
TB2
21 22
I2+
RTN
I3+
RTN
23 24
RTN
26 25
RTN
TB1
V0+
RTN
12 11
ANALOG OUTPUTS
13
RTN
V1+
RTN
14 15
ANALOG OUTPUTS
16
RTN
TB2
21 22
V2+
RTN
V3+
RTN
23 24
RTN
26 25
RTN
TB1/TB2
+
L
R
I
TB1/TB2
+
L
R
WIRING CONNECTIONS
SAME AS 913/914MB
10 TO 36V DC?
OR 24V AC?
NON-POLARIZED
I+
RTN
V+
RTN
62
9 0 0 M B S e r i e s
Modbus I/O BusWorks ?
924MB
Multi-Channel
Temperature
Control Modules
Thermocouple or
Millivolt Input
Limit Alarms or
Discrete Outputs
Model
924MB: 4 input channels
Input
Four input channels:
Thermocouple (types J, K, T, R, S, E, B, N),
±100mV DC
Output
Four output channels:
Open-drain MOSFETs (1A DC loads)
0 to 35V DC
Network Communication
Modbus-RTU high-speed RS-485
Power Requirement
10 to 36V DC,
24V AC
Approvals
CE marked. UL, cUL listed
Class I; Division 2; Groups A, B, C, D.
I Description
This signal conditioner is a four-channel analog
input module with four discrete outputs. It filters
and linearizes thermocouple inputs while provid-
ing isolation between input, output, power, and
network circuits. Cold junction compensation
and upscale/downscale sensor break detection
are standard. AC and DC power sources are sup-
ported with nonpolarized, diode-coupled termi-
nals.
The programmable inputs accommodate eight
thermocouple types plus wide-range millivolt
signals. Flexible discrete outputs operate as
alarms or on/off controllers. As limit alarms, each
discrete output can be configured with high
and/or low setpoints exclusively tied to an analog
input channel. Alarm trips function without host
communication enabling low-cost stand-alone
alarms as well as local backup for the primary
control system. Otherwise, on/off control is
based on commands issued by the host system.
Combining flexible transmitter functions, mixed
signal I/O, alarm support, and a network inter-
face in a single package, makes this instrument
extremely powerful. Multi-channel design adds
cost-efficiency and allows high-density mounting.
Plus, safe, rugged construction makes these
modules reliable for use in both control room
and distributed field I/O applications. Custom
module configurations are also possible (consult
factory for details).
I Special Features
I Standard Modbus RTU protocol with high-speed
RS-485 communication (up to 115K bps)
I 16-bit sigma-delta A/D yields 0.1°C resolution
and 0.5°C measurement accuracy
I Thermocouple linearization and sensor break
detection ensure reliable measurements
I Four discrete outputs enable local temperature
limit alarms or host-controlled on/off switching
I Heavy-duty 1A solid-state relays provide
dependable on/off control of industrial devices
I Self-calibration lowers maintenance costs by
reducing periodic manual calibration checks
I Watchdog timers provide a configurable
failsafe output state for use when host
I/O communication is lost
I Four-way isolation eliminates potential ground
loops between power, input, output and
network circuitry
I Self-diagnostics monitor microcontroller activity
to detect operational failures (lock-up) and
execute a reset to restore communication
Modbus
Four?
Thermocouple?
or?
DC Millivolt?
Inputs RS-485
10-36V DC?
or 24V AC
Isolation
Four?
Discrete?
Outputs?
or?
Limit Alarms
Power
Outputs (4) Inputs (2)
Inputs (2)
Thermocouple/Millivolt Input Module
Modbus/RS-485
63
M o d b u s I / O
Modbus I/O BusWorks ?
I Performance
I General Input
Resolution
±100mV DC input: 0.1%.
Thermocouple input: 0.1°C (0.18°F).
Ambient Temperature Effect
Better than ±0.005% of input span per °C, or
±1.0uV/°C, whichever is greater.
Noise Rejection
Normal mode: 40dB @ 60Hz, typical.
Common mode: 140dB @ 60Hz, typical.
Input Filter Bandwidth
-3dB at 3Hz, typical.
Input Conversion Rate
90ms per channel.
I Thermocouple Input
Thermocouple Input Ranges
Thermocouple type user-configured. Type selected
applies to all channels. Signal linearization, cold-junc-
tion compensation, and open circuit or lead break
detection are included.
TC °C Range (°F Range) Accuracy
J -210 to 760°C (-346 to 1400°F) ±0.5°C
K -200 to 1372°C (-328 to 2502°F) ±0.5°C
T -260 to 400°C (-436 to 752°F) ±0.5°C
R -50 to 1768°C (-58 to 3214°F) ±1.0°C
S -50 to 1768°C (-58 to 3214°F) ±1.0°C
E -200 to 1000°C (-328 to 1832°F) ±0.5°C
B 260 to 1820°C (500 to 3308°F) ±1.0°C
N -230 to 1300°C (-382 to 2372°F) ±1.0°C
Note 1: Accuracy is given with CJC switched off.
Relative inaccuracy with CJC enabled may increase
by ±0.5°C.
Thermocouple Break Detection
TC sensor failure can be configured for either upscale
or downscale. Selection applies to all channels.
I DC Millivolt Input
Millivolt Input Ranges
±100mV DC.
Millivolt Input Accuracy
±0.1% of input range.
I Discrete Output
Output Type
Four independent open drain MOSFET switches with a
common return that operate as low-side switches.
Output Voltage Range
0 to 35V DC, 1A DC maximum for each output.
External voltage source required.
Output ON Resistance
0.15 ohms maximum.
Operation
Digital outputs are set to their OFF state following a
software or power-on reset. Outputs can optionally
be set to user-defined states following a watchdog
timeout. Watchdog timeout output control takes
precedence over limit alarm control. Alarm control
takes precedence over host control.
Output Response Time
4.1ms typical, from receipt of command to gate
transition of the output MOSFET.
I Communication
Supported Modbus Commands
The command/response protocol for communicating
with this module adheres to the Modbus/RTU standard
for the following Modbus Functions.
Read Coil
Read Holding Registers
Read Input Registers
Force Single Coil
Preset Single Register
Force Multiple Coils
Preset Multiple Registers
Report Slave ID
Reset Slave
LED Indicators
LEDs indicate power, status, and discrete level/alarm.
I Power and Isolation
Power Requirements
10 to 36V DC,
22 to 26V AC.
Supply Current
Supply Current Draw
10V DC 100mA maximum
24V DC 45mA maximum
24V AC 85mA rms maximum
Isolation
1500V AC for 60 seconds or 250V AC continuous.
4-way isolation between input, network, power and
discrete I/O circuits. Inputs are isolated channel-to-
channel for common mode voltage to ±5V DC.
I Ordering
Information
924MB-0900
Thermocouple/millivolt input module
900C-SIP
Configuration Software Interface Package
(includes software CD-ROM for Windows, RS-232/485
converter, and RS-485/three-wire cable)
4001-095
USB-to-RS232 adapter. See page 70 for more info.
TBK-B01
Optional terminal block kit, barrier strip style, 2 pcs.
(Does not include terminal block for input wiring.)
TBK-S02
Optional terminal block kit, spring clamp style, 2 pcs.
(Does not include terminal block for input wiring.)
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
For more information on software, network hardware,
and mounting accessories, please see Pages 69-71.
TC INPUT
ANALOG INPUT
CONNECTIONS
TB1/TB2
IN+
VOLTAGE
IN-
SOURCE
-
+
TB1/TB2
IN+
IN-
DIGITAL OUTPUTS
45 46
TB4
OUT3
RTN
DIGITAL OUTPUT
TB4
RTN
OUT2
OUT1
44 43 42 36 41
TB3
OUT0
11
TB1
12
CJC-0
13
IN0+
IN0-
14 15 16
IN1+
IN1-
INPUTS 0,1 CJC-1
TB2
21
IN3+
IN3-
25 26 24
IN2-
23
IN2+
22
INPUTS 2,3
D
COM
COM
D
RS485
33 34 35 31 32
A
B
PWR
TB3
TB1
ANALOG?
INPUT
ANALOG?
INPUT
TB2
AC/DC?
POWER
NETWORK?
COMMUNICATION
VOLTAGE INPUT
DIGITAL OUTPUT CONNECTIONS
OUT 3
OUT 0
OUT 2
RTN
OUT 1
RTN
TB4
OUT
RTN
DIGITAL OUT
SHARES
RETURN
10 TO 36V DC?
OR 24V AC?
NON-POLARIZED
UP TO
35V DC
MECHANICAL?
RELAY INTERFACE
+
RTN
OUT
64
9 0 0 M B S e r i e s
Modbus I/O BusWorks ?
932/934MB
Multi-Channel
Temperature
Control Modules
RTD or Resistance
Input
Limit Alarms or
Discrete Outputs
Models
932MB: 2 input channels, 2 relay outputs
934MB: 4 input channels, 4 relay outputs
Input
RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu),
Resistance (0 to 500 ohms)
Output
Solid-state relays, Form A, SPST-NO
Network Communication
Modbus-RTU high-speed RS-485
Power Requirement
10 to 36V DC,
24V AC
Approvals
CE marked. UL, cUL listed
Class I; Division 2; Groups A, B, C, D.
I Description
This signal conditioner is a dual or quad-channel
analog input module with one discrete/relay out-
put per input channel and a Modbus interface. It
filters and linearizes RTD or resistance inputs
while providing isolation between input, output,
power, and network circuits. Lead wire compen-
sation and upscale/downscale sensor break
detection are standard. Low voltage AC and DC
power sources are supported with nonpolarized,
diode-coupled terminals.
The programmable inputs accommodate four
RTD types plus wide-range resistance signals.
Flexible discrete outputs operate as alarms or
on/off controllers. As limit alarms, each discrete
output can be configured with high and/or low
setpoints exclusively tied to an analog input
channel. Alarm trips function without host com-
munication enabling low-cost stand-alone alarms
as well as local backup for the primary control
system. Otherwise, on/off control is based on
commands issued by the host system.
Combining flexible transmitter functions, mixed
signal I/O, alarm support, and a network inter-
face in a single package, makes this instrument
extremely powerful. Multi-channel design adds
cost-efficiency and allows high-density mounting.
Plus, safe, rugged construction makes these
modules reliable for use in both control room
and distributed field I/O applications. Custom
module configurations are also possible (consult
factory for details).
I Special Features
I Standard Modbus RTU protocol with high-speed
RS-485 communication (up to 115K bps)
I 16-bit sigma-delta A/D yields 0.1°C resolution
and 0.25°C accuracy (Pt, Ni RTDs)
I RTD linearization and sensor break detection
ensure reliable measurements
I Discrete relay outputs enable local temperature
limit alarms or host-controlled on/off switching
I Heavy-duty 1A solid-state relays provide
dependable on/off control of industrial devices
I Self-calibration lowers maintenance costs by
reducing periodic manual calibration checks
I Watchdog timers provide a configurable
failsafe output state for use when host
I/O communication is lost
I Four-way isolation eliminates potential ground
loops between power, input, output and
network circuitry
I Self-diagnostics monitor microcontroller activity
to detect operational failures (lock-up) and
execute a reset to restore communication
Modbus
Four?
RTD?
or?
Resistance?
Inputs RS-485
10-36V DC?
or 24V AC
Isolation
Four?
Discrete?
Outputs?
or?
Limit Alarms
Power
Outputs (4) Inputs (2)
Inputs (2)
RTD/Resistance Input Module
Modbus/RS-485
65
M o d b u s I / O
Modbus I/O BusWorks ?
I Performance
I RTD/Resistance Input
Input Ranges
Input type user-configured. Type selected applies to all
channels. RTD linearization, lead wire compensation,
and open circuit or lead break detection are included.
Input Type Alpha Input Range Accuracy
Pt 100 ohm 1.3850 -200 to 850°C ±0.25°C
Pt 100 ohm 1.3911 -200 to 850°C ±0.25°C
Ni 120 ohm 1.6720 -80 to 320°C ±0.25°C
Cu 10 ohm 1.4272 -200 to 260°C ±1.00°C
Resistance linear 0 to 500 ohms ±0.05 ohm
Resolution
Input Type Alpha Resolution
Pt 100 ohm 1.3850 0.1°C
Pt 100 ohm 1.3911 0.1°C
Ni 120 ohm 1.6720 0.1°C
Cu 10 ohm 1.4272 0.2°C
Resistance linear 7.8125 milliohms
Ambient Temperature Effect
Better than ±0.005% of input span per °C, or
±1.0uV/°C, whichever is greater.
Noise Rejection
Normal mode: 40dB @ 60Hz, typical.
Common mode: 130dB @ 60Hz, typical.
Input Filter Bandwidth
-3dB at 3Hz, typical.
Input Conversion Rate
300ms per channel typical.
RTD Break Detection
Sensor failure can be configured for either upscale or
downscale. Selection applies to all channels.
Excitation Current
1mA DC typical, all types.
Lead-Wire Compensation
Inherent for 3-wire RTD. The maximum lead resistance
is 25 ohms per lead (Pt), 20 ohms per lead (Ni), 10
ohms per lead (Cu). All lead wires must be of equal
size and length.
I Discrete Output
Output Type
Solid-State Relay (SSR), one Form A (SPST-NO) switch
per input channel. Outputs share a common return
connection at the RTN terminals for low side switching
Output Voltage Range
0 to 48V DC, 1A DC.
Output ON Resistance
0.4 ohms maximum.
Output Response Time
4.1ms typical, from receipt of command to gate
transition of the output MOSFET.
Operation
Digital outputs are set to their OFF state following a
software or power-on reset. Outputs can be set to
user-defined states following a watchdog timeout.
I Communication
Supported Modbus Commands
The command/response protocol for communicating
with this module adheres to the Modbus/RTU standard
for the following Modbus Functions.
Read Holding Registers Read Coil
Read Input Registers Reset Slave
Preset Single Register Report Slave ID
Force Multiple Coils Force Single Coil
Preset Multiple Register
LED Indicators
LEDs indicate power, status, and discrete level/alarm.
I Power and Isolation
Power Requirements
10 to 36V DC (56mA max. at 24V DC).
22 to 26V AC (94mA rms max. at 24V AC).
Isolation
1500V AC for 60 seconds or 250V AC continuous.
4-way isolation between input, network, power and
discrete I/O circuits. Inputs are isolated channel-to-
channel for common mode voltage to ±5V DC.
I Ordering
Information
932MB-0900
Two channel RTD/Resistance input module
934MB-0900
Four channel RTD/Resistance input module
Accessories
900C-SIP
Configuration Software Interface Package
(includes software CD-ROM for Windows, RS-232/485
converter, and RS-485/three-wire cable)
4001-095
USB-to-RS232 adapter. See page 70 for more info.
TBK-B02
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S02
Optional terminal block kit, spring clamp style, 4 pcs.
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
For more information on software, network hardware,
and mounting accessories, please see Pages 69-71.
ANALOG INPUT
CONNECTIONS
DIGITAL OUTPUT
TB4 TB3
TB1
ANALOG?
INPUT
ANALOG?
INPUT
TB2
AC/DC?
POWER
NETWORK?
COMMUNICATION
DIGITAL OUTPUT CONNECTIONS
RTN
OUT 0
OUT 2
OUT 1
RTN
OUT 3
TB4
OUT
RTN
DIGITAL OUT
SHARES
RETURN
10 TO 36V DC?
OR 24V AC?
NON-POLARIZED
INL
IN-
IN+
IN+ IN+
INL
TB1/TB2
INL
IN-
TB1/TB2
IN-
TB1/TB2
JUMP
DECADE
BOX
JUMP
2-WIRE RTD
3-WIRE RTD RESISTANCE
D
D
A
TB1 TB4
12
IN0-
45
RTN
13
IN0L
44
OUT2
15
IN1-
42
RTN
16
IN1L
41
OUT0
TB3
21
IN2+
36
LRTN
23
INL2
34
24
IN3+
33
26
INL3
31
PWR
B
11 14
IN0+
IN1+
46 43
OUT3
OUT1
22
IN2-
TB2
35
COM
25
IN3-
32
934MB Only
RS485
RTD INPUTS 2,3
932MB/934MB
DIG. OUT DIG. OUT
RTD INPUTS 0,1
UP TO
48V DC
MECHANICAL?
RELAY INTERFACE
+
RTN
OUT
Optional terminal blocks: barrier strip (left) and
spring clamp (right). Cage clamp terminal is standard.
66
9 0 0 M B S e r i e s
Modbus I/O BusWorks ?
942MB
Frequency/
Pulse Counter
Modules
Periodic or Pulse
Waveform Input
Limit Alarms or
Discrete Outputs
Model
942MB: 2 input channels
Input
Two input channels:
0 to 50KHz in three selectable ranges
Amplitudes up to 140V AC or 200V peak
Pulse counter range of 0 to 65535
Output
Two output channels:
Solid-state relays (1A DC loads)
0 to 48V DC
Network Communication
Modbus-RTU high-speed RS-485
Power Requirement
10 to 36V DC,
24V AC
Approvals
CE marked. UL, cUL listed
Class I; Division 2; Groups A, B, C, D.
I Description
This signal conditioner is a two-channel analog
input module with discrete outputs and Modbus
communication. It conditions periodic or pulse
waveform inputs and provides solid-state relays
for limit alarms or ON/OFF control.
Versatile inputs accommodate many applications
using TTL, magnetic pickups, proximity sensors,
or a variety of switches (high/low-side transistor,
dry contact, open drain, open collector). Bipolar
and unipolar waveforms are supported with a
selectable input bias that accepts both zero and
non-zero crossing signals. Voltage threshold and
relative hysteresis are also user selectable.
Inputs may also function as event counters with
separate microcontrollers for each channel. The
module counts pulses on the positive or negative
edge. It can wrap around to zero for continuous
counting, latch at a programmed count value
(setpoint), or automatically reset itself to zero
after reaching a setpoint value. Software controls
enable remote resets. A variety of filters help
remove noise, jitter, and other mechanical effects
to prevent false counts.
The discrete outputs can operate as independent
alarms or provide on/off control regulated by the
host system. As limit alarms, each output can be
set for high and/or low setpoints exclusively tied
to an analog input. These low cost modules are
ideal for standalone alarms as well as for local
backup of the primary control system.
I Special Features
I Standard Modbus RTU protocol with high-speed
RS-485 communication (up to 115K bps)
I Separate microcontrollers on each channel for
pulse counting and period measurement
I Solid-state relay outputs enable local limit
alarms or host-controlled on/off switching
I Bipolar and unipolar input signal support
I Programmable pulse counter functions
I Input filtering functions include hysteresis,
averaging, debounce, relay time delay, and
alarm deadband controls
I 4-way isolation (input, output, power, network)
I Watchdog timers provide a failsafe output
I Self-diagnostics monitor microcontroller activity
to detect operational failures (lock-up) and
execute a reset to restore communication
Modbus
Two
Frequency
or
Pulse
Waveform
Inputs
RS-485
10-36V DC?
or 24V AC
Isolation
Two
Discrete?
Outputs?
or?
Limit Alarms
Power
Outputs (2) Inputs (2)
Frequency/Counter Module
Optional terminal blocks: barrier strip (left) and
spring clamp (right). Cage clamp terminal is standard.
Modbus/RS-485
67
M o d b u s I / O
Modbus I/O BusWorks ?
I Performance
I Frequency/Counter Input
Input Ranges
Input type user-configured. Applies to both channels.
Input Range Accuracy Accuracy over Temp.
0 to 100Hz ±0.04Hz ±0.06Hz
0 to 1000Hz ±0.4Hz ±0.6Hz
0 to 50,000Hz ±10Hz ±15Hz
0 to 65,535 pulses ±1 pulse ±1 pulse
Unipolar Input Configuration
Amplitude: 0 to 3V minimum range,
0 to 200V peak maximum range.
Threshold: Configurable for 1.5V or 5V, typical.
Hysteresis: Configurable for ±25mV (at 1.5V thresh-
old), or ±83mV (at 5.0V threshold), typical.
Bipolar (Zero-Crossing) Input Configuration
Amplitude (0-20KHz): ±50mV minimum (with ±25mV
hysteresis), or ±150mV minimum (with ±83mV hys-
teresis), to ±200V peak maximum.
Amplitude (Above 20KHz): ±100mV minimum (with
±25mV hysteresis), or ±200mV minimum (with ±83mV
hysteresis), to ±200V peak maximum.
Threshold: 0mV nominal, 0.01V typical with ±25mV
hysteresis; 0.03V typical with ±83mV hysteresis.
Hysteresis: Configurable for ±25mV or ±83mV, typical.
Resolution
0 to 100Hz input range: 0.01Hz
0 to 1000Hz input range: 0.1Hz
0 to 50,000Hz input range: 1Hz
Pulse counter: 1 pulse
Minimum Input Pulse Width
10μS (frequency input); 5mS (pulse input).
Counting Rate
100Hz maximum counting rate
(5mS ON and 5mS OFF for 10mS period or 100Hz).
Input Impedance
35K ohms, typical.
Input Filter Bandwidth
-3dB at 35kHz, typical.
Input Pullup/Pulldown
Software selectable 2.7K ohm input pullup to +5V and
a 1K ohm input pulldown to return. The resistors may
also be left floating (none).
Input Debounce
0 to 1.375 seconds, configurable in 5mS increments.
Noise Rejection
Common mode: 80dB @ 60Hz, typical with 100 ohm
input unbalance.
I Discrete Output
Output Type
Solid-State Relay (SSR), one Form A (SPST-NO) switch
per input channel. Outputs share a common return
connection at the RTN terminals for low-side switching
Output Voltage Range
0 to 48V DC, 1A DC.
Output ON Resistance
0.4 ohms maximum.
Output Response Time
4.1ms typical, from receipt of command to gate
transition of the output MOSFET.
Operation
Digital outputs are set to their OFF state following a
software or power-on reset. Outputs can be set to
user-defined states following a watchdog timeout.
I Communication
Supported Modbus Commands
The command/response protocol for communicating
with this module adheres to the Modbus/RTU standard
for the following Modbus Functions.
Read Holding Registers Read Coil
Read Input Registers Reset Slave
Preset Single Register Report Slave ID
Force Multiple Coils Force Single Coil
Preset Multiple Registers
LED Indicators
LEDs indicate power, status, and discrete level/alarm.
I Power and Isolation
Power Requirements
10 to 36V DC.
22 to 26V AC.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
4-way isolation between input, network, power and
discrete I/O circuits. Inputs are isolated channel-to-
channel for common mode voltage to ±5V DC.
I Ordering
Information
942MB-0900
Frequency/counter input module
Accessories
900C-SIP
Configuration Software Interface Package
(includes software CD-ROM for Windows, RS-232/485
converter, and RS-485/three-wire cable)
4001-095
USB-to-RS232 adapter. See page 70 for more info.
TBK-B02
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S02
Optional terminal block kit, spring clamp style, 4 pcs.
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
For more information on software, network hardware,
and mounting accessories, please see Pages 69-71.
FREQUENCY INPUT
ANALOG INPUT
CONNECTIONS
DIGITAL OUTPUTS
45 46
TB4
DIGITAL OUTPUT
TB4
RTN
OUT1
44 43 42 36 41
TB3
OUT0
11
TB1
12
FREQ. INPUT 0, 1
13
RTN
NC
14 15 16
FRQ1
RTN
D
COM
COM
D
RS485
33 34 35 31 32
A
B
PWR
TB3
TB1
ANALOG?
INPUT
AC/DC?
POWER
NETWORK?
COMMUNICATION
DIGITAL OUTPUT CONNECTIONS
OUT 3
OUT 0
OUT 2
RTN
OUT 1
RTN
TB4
OUT
RTN
DIGITAL OUT
SHARES
RETURN
10 TO 36V DC?
OR 24V AC?
NON-POLARIZED
FRQ0
RTN
FRQ1
RTN
FREQUENCY
GENERATOR
-
+
MAGNETIC
PICKUP
-
+
HIGH-SIDE SWITCH?
(Open Collector/Drain)
FRQ0
RTN
FRQ0
RTN
FRQ0
RTN
MAGNETIC INPUT
or
FRQ0
RTN
or
V+ V+ V+ V+
LOW-SIDE SWITCH?
(Open Collector/Drain)
DRY CONTACT
FRQ0
RTN
TTL
V+ V+ V+
NC
FRQ0
UP TO
48V DC
MECHANICAL?
RELAY INTERFACE
+
RTN
OUT
TB1
54
9 0 0 M B S e r i e s
Modbus I/O BusWorks ?
901/902/903MB
Multi-Channel
Discrete I/O
Modules
Active-Low Inputs
Sinking Outputs
(Low-Side Switching)
Models
901MB: 12 input channels
902MB: 12 output channels
903MB: 12 input/output channels
Input
Twelve input channels (901, 903 models only)
0 to 35V DC
Output
Twelve output channels (902, 903 models only)
O to 35V DC
Network Communication
Modbus-RTU high-speed RS-485
Power Requirement
10 to 36V DC,
24V AC
Approvals
CE marked. UL, cUL listed
Class I; Division 2; Groups A, B, C, D.
I Description
These modules provide twelve discrete input
and/or output channels. Isolation separates the
I/O, power, and network circuits. Network
communication adheres to the industry-standard
RS-485 Modbus RTU protocol. Both AC and DC
power sources are supported with wide range,
nonpolarized, diode-coupled terminals.
The open-drain outputs are intended for current-
sinking or low-side switching applications. The
buffered inputs are active-low. These models are
the complement of the 904, 905, and 906 units
which have open-source, high-side output
switches and active-high inputs. Socketed pull-up
resistors are easily removed or exchanged to sat-
isfy your application requirements.
The 903MB model has twelve input/output
points that may be used as inputs or outputs on
a bit-by-bit basis. Outputs may be read back to
verify output settings.
Combining flexible I/O types, wide I/O ranges,
and a network interface in a single package,
makes this instrument extremely powerful.
Multi-channel design adds cost-efficiency and
allows high-density mounting. Plus, safe, rugged
construction makes these modules reliable for
use in both control room and distributed field I/O
applications. Custom module configurations are
also possible (consult factory for details).
I Special Features
I Standard Modbus RTU protocol with high-speed
RS-485 communication (up to 115K bps)
I Twelve I/O channels in a single inch-wide unit
reduces system costs and saves panel space
I High-voltage, high-current, open-drain outputs
enable direct (low-side) control of external
devices
I High-voltage buffered inputs monitor discrete
levels from a variety of industrial devices
I Tandem input/output circuitry (903 models
only) connects input buffers with open-drain
outputs for convenient loopback monitoring of
the output state
I Outputs have built-in over-temperature and
over-current shut-down protection, plus active
clamping circuits for switching inductive loads
I Watchdog timers provide a configurable
failsafe output state for use when host
I/O communication is lost
I Three-way isolation eliminates potential
ground loops between power, I/O, and
network circuitry
I Self-diagnostics monitor microcontroller activity
to detect operational failures (lock-up) and
execute a reset to restore communication
Modbus
RS-485
10-36V DC?
or 24V AC
Isolation
Twelve?
Discrete?
Inputs or Outputs
Power
Inputs (4)
or
Outputs (4)
Inputs (4)
or
Outputs (4)
Inputs (4)
or
Outputs (4)
High-Density Discrete I/O Module
Modbus/RS-485
57
M o d b u s I / O
Modbus I/O BusWorks ?
■ Performance
■ Discrete Inputs
(901 & 903 models only)
Input Type
12 active-low, buffered inputs, with a common con-
nection. Inputs include transient suppression devices
and series connected 100K ohm resistors, plus diode
over-voltage clamps to the internal +5V supply.
Input Signal Voltage Range
0 to 35V DC, maximum.
Input Current
293μA, typical at 35V DC.
Input Signal Threshold
TTL compatible with 100mV of hysteresis, typical.
Low-to-High threshold is 1.7VDC, High-to-Low is
1.6VDC, typical. Limited to TTL levels of 0.8VDC
(max. LOW level) and 2.0VDC (min. HIGH level).
Input Resistance
100K ohms, typical.
Input Hysteresis
100mV DC, typical.
■ Discrete Outputs
(902 & 903 models only)
Output Type
12 independent, open-drain, DMOS MOSFET switches
with a common source connection that operate as
low-side switches.
Output Voltage Range
0 to 35V DC max. (0 to 500mA/channel continuous).
External voltage source required.
Output ON Resistance
0.28 ohms maximum.
Output Response Time
Force Single Coil: Output updates within 250μs of
receipt of a command.
Force Multiple Coils: First coil updates in 250μs,
followed successively by additional coils every 180μs.
■ General
I/O Pull-ups and Socket
5.6K ohm pull-up resistor SIPs are installed in sockets
at each port (four-channels per port).
Excitation (per port)
External excitation voltage for each four-channel port
is limited to 35V or less.
Supported Modbus Commands
The command/response protocol for communicating
with this module adheres to the Modbus/RTU standard
for the following Modbus Functions.
Read Coil (Output) Status
Read Input Status
Read Holding Registers
Force Single Coil (Output)
Preset Single Register
Reset Slave
Force Multiple Coils (Outputs)
Preset Multiple Registers
Report Slave ID
LED Indicators
LEDs indicate power, status, and discrete level.
Power Requirements
10 to 36V DC,
22 to 26V AC.
Supply Current
Supply Current Draw
10V DC 130mA maximum
24V DC 54mA maximum
24V AC 95mA maximum
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power
circuits.
■ Ordering
Information
Models
901MB-0900
Discrete input module
902MB-0900
Discrete output module
903MB-0900
Discrete input/output module
Accessories
900C-SIP
Configuration Software Interface Package
(includes software CD-ROM for Windows, RS-232/485
converter, and RS-485/three-wire cable)
4001-095
USB-to-RS232 adapter. See page 70 for more info.
TBK-B02
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S02
Optional terminal block kit, spring clamp style, 4 pcs.
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
For more information on software, network hardware,
and mounting accessories, please see Pages 69-71.
DIGITAL INPUT CONNECTIONS (ACTIVE LOW) DIGITAL OUTPUT CONNECTIONS
RTN
+5V
INP
INP
RTN
CH 0
RTN
CH 1
CH 2
CH 3
5V TTL LOGIC - INPUT CAN BE PULLED
UP INTERNALLY OR EXTERNALLY
DIGITAL I/O
SHARES
RETURN
EXC1
TB1
INTERNAL INPUT
PULL-UPS ARE PRESENT
DIGITAL IN or OUT
CH11
RTN
46 45 44
CH10
RS485
41 42 43
EXC3
TB4
CH 8
CH 9
35 36
COM
COM
TB1
DIGITAL IN or OUT
12 11
CH 0
EXC1
CH 1
13 14 15
CH 2
CH 3
RTN
16
DIGITAL IN or OUT
TB2
21
EXC2
CH 4
22 24 23
CH 6
CH 5
RTN
CH 7
25 26
34 33
D
D
31 32
TB3
PWR
DIGITAL
I/O
10 TO 36V DC
OR 24V AC
NON-POLARIZED
DIGITAL
I/O
DIGITAL
I/O
AC/DC
POWER
NETWORK
COMMUNICATION
903MB shown.
901MB & 902MB
are similar.
A
B
TB3
TB2
TB4
TB1
CH 0
RTN
CH 1
CH 2
CH 3
EXC1
TB1
OUT
RTN
DIGITAL I/O
SHARES
RETURN
EXC
INP
SPST
RELAY
12-24V DC,
TYPICAL
+
RTN
EXC
RTN
INP
5-35V
V
RTN
I/O
902MB/903MB
ON
TO OTHER 3
CHAN OF PORT 100K
OFF
EXC
903MB
+5V
LOAD
Optional terminal blocks: barrier strip (left) and
spring clamp (right). Cage clamp terminal is standard.
56
9 0 0 M B S e r i e s
Modbus I/O BusWorks ?
904/905/906MB
Multi-Channel
Discrete I/O
Modules
Active-High Inputs
Sourcing Outputs
(High-Side Switching)
Models
904MB: 12 input channels
905MB: 12 output channels
906MB: 12 input/output channels
Input
Twelve input channels (904, 906 models only)
0 to 35V DC
Output
Twelve output channels (905, 906 models only)
6 to 35V DC
Network Communication
Modbus-RTU high-speed RS-485
Power Requirement
10 to 36V DC,
24V AC
Approvals
CE marked. UL, cUL listed
Class I; Division 2; Groups A, B, C, D.
I Description
These modules provide twelve discrete input
and/or output channels. Isolation separates
the I/O, power, and network circuits. Network
communication adheres to the industry-standard
RS-485 Modbus RTU protocol. Both AC and DC
power sources are supported with wide range,
nonpolarized, diode-coupled terminals.
The outputs are intended for current-sourcing or
high-side switching applications. The buffered
inputs are active-high. These models are the
complement of the 901, 902, and 903 units
which have low-side output switches and
active-low inputs. Socketed pull-down resistors
are easily removed or exchanged to satisfy your
application requirements.
The 906MB model has twelve input/output
points that may be used as inputs or outputs on
a bit-by-bit basis. Outputs may be read back to
verify output settings.
Combining flexible I/O types, wide I/O ranges,
and a network interface in a single package,
makes this instrument extremely powerful.
Multi-channel design adds cost-efficiency and
allows high-density mounting. Plus, safe, rugged
construction makes these modules reliable for
use in both control room and distributed field I/O
applications. Custom module configurations are
also possible (consult factory for details).
I Special Features
I Standard Modbus RTU protocol with high-speed
RS-485 communication (up to 115K bps)
I Twelve I/O channels in a single inch-wide unit
reduces system costs and saves panel space
I High-voltage, high-current, open-source
outputs enable direct (high-side) control of
external devices
I High-voltage buffered inputs monitor discrete
levels from a variety of industrial devices
I Tandem input/output circuitry (906 models
only) connects input buffers with open-source
outputs for convenient loopback monitoring of
the output state
I Watchdog timers provide a configurable
failsafe output state for use when host
I/O communication is lost
I Three-way isolation eliminates potential
ground loops between power, I/O, and
network circuitry
I Self-diagnostics monitor microcontroller activity
to detect operational failures (lock-up) and
execute a reset to restore communication
Modbus
RS-485
10-36V DC?
or 24V AC
Isolation
Twelve?
Discrete?
Inputs or Outputs
Power
Inputs (4)
or
Outputs (4)
Inputs (4)
or
Outputs (4)
Inputs (4)
or
Outputs (4)
High-Density Discrete I/O Module
Modbus/RS-485
57
M o d b u s I / O
Modbus I/O BusWorks ?
I Performance
I Discrete Inputs
(904 & 906 models only)
Input Type
12 active-high, buffered inputs, with a common con-
nection. Inputs include transient suppression devices
and series connected 100K ohm resistors, plus diode
over-voltage clamps to the internal +5V supply.
Input Signal Voltage Range
0 to 35V DC, maximum.
Input Current
293μA, typical at 35V DC.
Input Signal Threshold
TTL compatible with 100mV of hysteresis, typical.
Thus, Low-to-High threshold is 1.5VDC, High-to-Low is
1.4VDC, typical. Limited to TTL levels of 0.8VDC
(max. LOW level) and 2.0VDC (min. HIGH level).
Input Resistance
5.6K ohms with standard factory pull-down resistors
installed. 100K ohms without pull-downs.
Input Hysteresis
100mV DC, typical.
Input Response Time
500ns for low-to-high, 2μS for high-to-low, typical.
Microcontroller samples inputs as a group every 10mS.
I Discrete Outputs
(905 & 906 models only)
Output Type
12 independent, open-source, MOSFET switches that
operate as high-side switches.
Output Voltage Range
6 to 35V DC (0 to 250mA/channel continuous).
External excitation voltage required.
Output ON Resistance
0.15 ohms maximum.
Output Response Time
Outputs update within 50ms of a write command and
switch within 5mS of receipt of command. Loopback
response (906MB) is 1μS low-to high, 5μS high-to-low.
I General
I/O Pull-downs and Socket
5.6K ohm pull-down resistor SIPs are installed in
sockets at each port (four-channels per port).
Excitation (per port)
External excitation voltage for each four-channel port
is limited to 35V or less.
Supported Modbus Commands
The command/response protocol for communicating
with this module adheres to the Modbus/RTU standard
for the following Modbus Functions.
Read Coil (Output) Status
Read Input Status
Read Holding Registers
Read Input Registers
Force Single Coil (Output)
Preset Single Register
Reset Slave
Force Multiple Coils (Outputs)
Preset Multiple Registers
Report Slave ID
LED Indicators
LEDs indicate power, status, and discrete level.
Power Requirements
10 to 36V DC,
22 to 26V AC.
Supply Current
Supply Current Draw
10V DC 90mA maximum
24V DC 40mA maximum
24V AC 75mA rms maximum
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power
circuits.
I Ordering
Information
Models
904MB-0900
Discrete input module
905MB-0900
Discrete output module
906MB-0900
Discrete input/output module
Accessories
900C-SIP
Configuration Software Interface Package
(includes software CD-ROM for Windows, RS-232/485
converter, and RS-485/three-wire cable)
4001-095
USB-to-RS232 adapter. See page 70 for more info.
TBK-B02
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S02
Optional terminal block kit, spring clamp style, 4 pcs.
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
For more information on software, network hardware,
and mounting accessories, please see Pages 69-71.
DIGITAL INPUT CONNECTIONS (ACTIVE HIGH)
DIGITAL IN or OUT
45 46
TB4
CH11
COM
TB4
CH 9
CH10
CH 8
44 43 42 36 41
TB3
EXC3
10 TO 36V DC?
OR 24V AC?
NON-POLARIZED
D
COM
COM
D
RS485
33 34 35 31 32
A
B
PWR
TB3
TB1
DIGITAL?
I/O
DIGITAL?
I/O
DIGITAL?
I/O
TB2
AC/DC?
POWER
NETWORK?
COMMUNICATION
TB1
EXC1
CH 0
12 11
DIGITAL IN or OUT
13
CH 1
CH 2
CH 3
14 15 16
RTN
TB2
EXC2
CH 4
22 21
DIGITAL IN or OUT
23
CH 5
CH 6
CH 7
24 25 26
RTN
906MB shown.?
904MB & 905MB?
are similar.
INP
COM
INP
RTN
+5V
COM
INP
TB1
RTN
CH 3
CH 2
CH 1
CH 0
EXC1
DIGITAL I/O?
SHARES
COMMON
INTERNAL ?
INPUT ?
PULL-DOWNS?
ARE PRESENT
5V TTL LOGIC INPUT IS ACTIVE HIGH?
AND PULLED DOWN INTERNALLY
DIGITAL OUTPUT CONNECTIONS
CH 0
RTN
CH 1
CH 2
CH 3
EXC1
TB1
OUT
RTN
DIGITAL I/O
SHARES
RETURN
UP TO?
35V DC
SPST?
RELAY
+
RELAY COIL/SOLENOID DRIVER (905MB/906MB)
Locate
Snubber
at Coil
5-35V
Typical
ON (1)
EXC
I/O
RTN
905MB
OFF (0)
R
TO OTHER 3
CHAN OF PORT
CH
LED
OPEN
INTERNAL PULL-
DOWN IS OPEN
FOR 905MB
+
Optional terminal blocks: barrier strip (left) and
spring clamp (right). Cage clamp terminal is standard.
68
9 0 0 M B S e r i e s
Modbus I/O BusWorks ?
26 25 24
TB2 TB1
(110.5)
4.35
(99.1)
3.90
23 22 21
TB2
16 15 12 13 14 11
TB1
D
A
B
PWR
TB3
33 31 32 36 34 35
TB4
41 42 43 44 45 46
D
COM
COM
RS485
TB3
TB4
DFT
3 2
1 0
ST
(118.9)
4.68
(95.3)
3.75
Acromag
RUN
C
L
(26.7)
1.05
(59.4)
2.34
NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS)
"T" Rail Din Mounting
Din EN 50022, 35mm
900MB Series Technical Diagrams
PERSONAL COMPUTER
W/ WINDOWS 95/98 OR NT
RS-232 SERIAL
PORT CONNECTOR
AT BACK OF PC
RS-232 TO RS-485 CONVERTER
MODEL 5034-214
900C-SIP COMMUNICATION CONNECTIONS
CONNECT THE RS-232
SIDE OF CONVERTER
TO THE PC
42 43 45 44
TB4
46
0 1
DFT
TB4
ST
STATUS LED (YELLOW)
RUN/PWR LED (GREEN)
DEFAULT MODE SWITCH -
PUSH FOR DEFAULT MODE.
STATUS LED FLASHES IN
DEFAULT MODE.
RUN
Acromag
INSTALL MODBUS
CONFIGURATION
SOFTWARE
CAUTION: DO NOT CONNECT THE
CABLE DIRECTLY TO THE PC WITHOUT
THE CONVERTER, OR DAMAGE TO
THE MODULE MAY RESULT.
CABLE 5034-202
COM
D
D
CONNECT THE RS-485
SIDE OF CONVERTER
TO THE CABLE
CONNECT WIRES AS SHOWN
RS-485
GREEN C
BLACK
RED
B
A
COLOR WIRE
B A
C
TB3
D
32
B
PWR
31
A
TB4
COM D
COM
COM
36 35
D
D
34 33
RS485
41
TB3
16 22 21
TB2
23 24 26 25
TB2 TB1
REFER TO THE USER'S MANUAL
THAT CAME WITH YOUR MODULE
TO COMPLETE THE MODULE'S
POWER AND I/O CONNECTIONS
3 2
R
TB1
12 13 11
ANY 900MB MODULE
TB1
14 15
PC RUNNING?
ACROMAG?
MODBUS CONFIG?
SOFTWARE
69
M o d b u s I / O
Modbus I/O BusWorks ?
Software
Interface Package
This package includes Windows ? Configuration
Software, an RS-232-to-485 Serial Port
Converter, and an RS-485 Signal Cable. These
components provide everything you need to set
up a Series 900 I/O module from your desktop
PC before installing it on the network.
I Ordering Information
900C-SIP
Software Interface Package.
Includes Configuration Software (5034-186),
Non-isolated RS-232 to RS-485 Serial Port Converter
(5034-214), and RS-485 Cable (5034-202).
Items can also be ordered separay below.
5034-186
Configuration Software for Windows (95/98/2000/ME/
NT4/XP) on CD-ROM.
5034-214
Non-isolated RS-232 to RS-485 Serial Port Converter,
DB-9F to DB-9F.
5034-202
RS-485 to 3-wire Cable Converter,
DB-9M to 3 x 12AWG RS-485 Cable, 8 ft.
Software Interface Package
Model No. 900C-SIP
RS-232 to RS-485
Converter
(non-isolated)
Configuration Software
for Windows
RS-485 Cable
(DB-9)
Configuration Kit
Universal 50W
Power Supply
The PS5R-D24 is the
ideal power source
to drive your
network.
Input Power
Requirement
Universal power
85 to 264V AC,
105 to 370V DC
Output
24V DC, 2.1A (50W)
I Ordering Information
PS5R-D24
Universal Power Supply
DIN-Rail
Mounting
For your convenience, Acromag offers several
mounting accessories to simplify your system
installation. Our 19” rack-mount kit provides a
clean solution for mounting your I/O modules
and a power supply. Or you can buy precut DIN
rail strips for mounting on any flat surface.
I Ordering Information
20RM-16-DIN
19" rack-mount kit with DIN rail.
DIN RAIL 3.0
DIN RAIL 16.7
DIN rail strip, Type T, 3 inches (75mm) or
16.7 inches (425mm)
V.ADJ
DC ON
M3.5
Terminal Screws
10-?6.5
4-?4.5
80
13 13 13 13
90
12
7.35
75
60 5
Top View
(dimensions in mm)
35.3
6
95
3.8
Side View
(dimensions in mm)
Dimensions in inches (mm).
RS-232/485?
Converter?
(non-isolated)
5034-214
RS-485?
to 3-wire
5034-202
Network Power
Mounting Hardware
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
PERSONAL COMPUTER
RUNNING WINDOWS
98/ME/2000/XP
6 FEET OF CABLE
USB MALE
DB9P
RS232
4001095
USB SERIAL CONVERTER
LED
TO HOST USB PORT HOST
USB
CONFIGURATION
SOFTWARE
ACROMAG
HOST PC RUNNING
Bulletin #8400-572
Description
This device is a USB-to-serial adapter that you
can use to communicate with many Acromag I/O
products for setup and re-configuration for your
application.
Key Features & Benefits
■ Connects to I/O modules via USB
(other adapters may be necessary)
■ Complete RS232 control signals
■ Conforms to USB Specification, Version 1.1
■ USB-powered
■ Cable length, 6 ft., UL approved
Performance Specifications
USB Specification
Version 1.1
Data rate
Up to 115.2Kbps
Environmental Standards
RoHS-compliant
Basic Power Consumption
150mA
PC Requirements
Windows ? 7 (32-/64-bit) / Vista (32-/64-bit) /
XP (32-/64-bit) / Server 2003 & 2008 (32-/64-bit) /
2000 / ME / 98SE / 98
Ordering Information
NOTE: For more information visit .
Adapters
4001-095
USB to serial adapter. Includes driver CD and manual.
5030-913
Serial port adapter. DB9S connector to RJ11 jack.
5034-202
RS-485 to 3-wire cable converter and cable, DB-9M to
3 x 12AWG RS-485 cable, 8 ft.
5032-287
RS-232 to 151T transmitter configuration device
converter and cable, 6 ft.
5034-214
Non-isolated RS-232 to RS-485 Serial Port Converter,
DB-9F to DB-9F.
Cables
5030-902
Cable. 6 feet long with RJ11 plug at each end.
Simplifies configuration of Acromag I/O Modules ◆ Enables configuration via USB port
Model 4001-095 USB-to-Serial Adapter
Accessories
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2009. Data subject to change without notice. Printed in USA 10/2009.
9-PIN CONNECTOR (DB9S)
RJ11 PLUG
(6 CONDUCTOR)
(6 CONDUCTOR)
RJ11 JACK
INLIPACK
MODEL 5030-913
SERIAL ADAPTER
MODEL 5030-902
(6 feet long)
B
C
D D
RS-232
COM
A
RS-485
5034-202
CABLE 5034-202
RS232 TO RS485 SERIAL
CONVERTER
(MODEL 5034-214)
DB9 MALE
DB9 FEMALE DB9 FEMALE
6 FEET OF CABLE
TOP VIEW
Acromag
1046-016
3 & 4 Wire RTD
3 4
+
-T/C, mV+
1 2
–
1
2
4
PLUG INTO TOP
OF TRANSMITTER
TOP VIEW
3
TO RS232
151T TRANSMITTER
151C-SIP
INTERFACE ADAPTER
Acromag
1046-016
Transmitter
temperature
of 151T
plug into top
MODEL 5032-787
InliPack 800x Series
Adapter and Cable
151T Transmitter Series
Adapter and Cable
900MB Modbus Series
Adapter and Cable
248-295-0880 ■ 248-624-9234 ■ ■ ■ 30765 Wixom Rd, Wixom, MI 48393 USA
Network Accessories: 4683 Series
Bulletin #8400-404d
Description
Models
4683-TTM-1F: 115V AC Power
4683-TTM-2F: 230V AC Power
4683-TTM-3F: 24V AC Power
Acromag’s RS-485 network repeater device
allows users to take full advantage of the RS-485
standard’s extended communication distances
and multi-dropping capabilities. In addition,
these devices offer field selectable End-of-Line
Network (EOLN) terminations on both the A and
B networks.
Operation is transparent to all devices and
no handshaking is required. Up to thirty-two
RS-485 devices can be driven. Network repeaters
are ready to mount on any base plate. Or, for
a harsh environment, it can be installed in a
NEMA enclosure of your choice. No enclosure
is necessary for use in a laboratory or office.
Installation requires mounting, connecting power
and cables, and setting the baud rate.
Approvals
UL/cUL listed:
Energy management equipment
Key Features & Benefits
■ Designed for use with Johnson Controls
N2 or BACnet bus
■ No handshaking
■ No extra control lines
■ I/O signal isolation
■ Baud rates of 600, 1200, 2400, 4800, 9600,
19.2K, 38.4K, and 76.8K are switch selectable
■ Field-selectable end-of-line network
terminations on both A and B sides
■ Electrical transient protection is provided. This
protects the host computer from destructive
noise spikes and other
transient signals.
■ Status LED’s indicate transmission
direction, RS-485 bus fault conditions, and
power applied.
■ 24/115/230V AC power available
■ No separate transformer required with 24V AC
units (4683-TTM-3F)
Operation
Model 4683-TTM-xF network repeaters
isolate and boost RS-485 signals allowing
communication signals to travel another 4000 ft.
Each repeater permits the addition of another 32
unit load to a network.
The repeater has two RS-485 “sides” known as
the A and B sides. The A side
typically connects to the network towards the
host and the B side connects to the extended
network. Functionally, the A and B sides are
equivalent.
Repeaters receive AC power through a 3-screw
terminal strip. Transient signal protection is
provided on both RS-485 sides.
When both RS-485 lines are idle, each side is
in receive mode. When a ‘1’ to ‘0’ transition is
detected (signifying a start bit) on either side,
the opposite side’s transmitter is enabled. The
transmitter stays enabled for one character’s time
(based on the baud rate switch setting). The
received character is then passed through.
For N2 or BACnet MS/TP bus ◆ Drives up to 32 RS-485 devices ◆ Isolates and boosts signal up to 4000 ft.
4683-TTM RS-485 to RS-485 Network Repeater
D D D COM D COM
RS-485
SIDE B
BAUD
RATE
G W
L2 G
FAULT
A
FAULT
B
AC (HI)
Status
LEDs
PWR
GROUND
L1
L1
RS-485
SIDE A
AC (LO)
NETWORK CONNECTIONS
4683-TTM-1F (115VAC)
4683-TTM-2F (230VAC)
4683-TTM-3F (24VAC) G COM HOT
1 - 600
2 - 1200
3 - 2400
4 - 4800
5 - 9600
6 - 19.2K
7 - 38.4K
8 - 76.8K
RS-485
SIDE B
24V DC
RTN
COM
D
D
D
R T
R T
_
24V DC
RS-485
SIDE A
COM
D
R T
R T
_
NC
S1
1 2 3 4 5 6 7 8
TX
A - B
TX
B - A
Status
LEDs
Baud Rate
Switches
AC
Input TB1 TB2
TB3
O
N
248-295-0880 ■ 248-624-9234 ■ ■ ■ 30765 Wixom Rd, Wixom, MI 48393 USA
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 9/2013.
4683-TTM RS-485 to RS-485 Network Repeater
Network Accessories: 4683 Series
Acromag, Inc. Phone:(248) 295-0880 ?: (248) 624-9234 - 4 - ?: ?On-Line: http://
The station configuration drawing is for general illustration purposes only. Johnson Controls
system customers should instead refer to the Metasys? Network Technical Manual for N2 Bus
Communication, or the MS/TP Communication Bus Technical Bulletin for wiring connections using the
4683-TTM-xF repeater.
R
R
R
R
T
D
32 6 5 8
D
R RR R
3
2
5
2
3
4
5
7
8
10
11
12
13
6
7
8
9
14
15
17
18
20
22
23
25
R
R R
COM
TX
B - A
R
COM
24VDC 24VDC
1
4
1
6
9
16
19
21
24
2
3
T
D
1 4 7
T T
D
W L2
POWER FAULT
A
BAUD
RATE
RS-485 SIDE A
A-N3
S1
NC
R
RS-485 SIDE B
TX
A - B
FAULT
B
RTN
OR
C
A
COM
TX
RX
TX
RX
5 COM
TX
RX
7
3
DSR
RX
RTS
G
L1
G
L1
G
A-N2
B
2
CD
CTS
TX
AC (LO)
-1 OPTION
115VAC
RED POWER LED
AC (LO) COM AC (LO)
-3 OPTION
24VAC
3 - 2400
4 - 4800
7 - 38.4K
8 - 76.8K
S1 - BAUD RATE
1 - 600 5 - 9600
1 - 600 5 - 9600
2 - 1200 6 - 19.2K
3 - 2400 7 - 38.4K
4 - 4800 8 - 76.8K
B-N1
NC
A-N32
A-N31
RS232
C
B
A
HOST
DE9
COM
DB25
Ground
AC (HI)
acromag
Ground
AC (HI)
Ground
HOT AC (HI)
ANY
RS485
DEVICES
S1 - SET BAUD RATE
TO MATCH BAUD
RATE OF NETWORK.
2 - 1200 6 - 19.2K
RS485 REPEATER
MODEL 4683-TTM-X
RS485
A-N30
B-N2 B-N3
RS485
B-N4 B-N5
UP TO 32
NODES PER
NETWORK
SEGMENT
B-N32
COM
SIGNALS AT
CONVERTER
HOST
RED RS485 FAULT LED (SIDE A)
TRANSMIT DIRECTION
B-TO-A & A-TO-B
-2 OPTION
230VAC
DE9
DB25
TO HOST
CONNECTIONS
TO HOST COMPUTER
HOST PC
RED RS485 FAULT LED (SIDE B)
NOTE: SIDE-A AND SIDE-B EOL
TERMINATION JUMPERS ENABLED
UP TO 32
NODES PER
NETWORK
SEGMENT
120 OHM TERMINATION
RESISTOR REQUIRED
AT END OF NETWORK
OR LAST DEVICE ONLY
IMPORTANT:
MODEL 4683-TTM-X UNITS
INCLUDE INTERNAL, FIELD
SELECTABLE END-OF-LINE
(EOL) TERMINATION
RESISTORS FOR THE A AND
B SIDES. THESE ARE
ENABLED VIA INTERNAL
JUMPERS. DO NOT USE
EXTERNAL TERMINATION
WITH INTERNAL EOL
JUMPERS ENABLED.
SEE UNIT LABEL
TO VERIFY POWER
REQUIREMENTS
NOTE: JUMPERED PINS ARE
NULL-MODEM CONNECTIONS
WHICH ALLOW COMMUNICATION
BETWEEN THE HOST AND
ACROMAG SERIES 4100/4200
I/O STATIONS.
EXTENDED NETWORK
ANY RS-485 DEVICE
MODEL 4683-TTM-XF REPEATER
SYSTEM CONNECTIONS
RS485
Converter
248-295-0880 ■ 248-624-9234 ■ ■ ■ 30765 Wixom Rd, Wixom, MI 48393 USA
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 9/2013.
4683-TTM RS-485 to RS-485 Network Repeater
Network Accessories: 4683 Series
3 2 1
J4
2
J1
2 2
J2
2
3
D
S1
D D
3 2 1
3
1
3
1
3
1
J4
1
8 6 7
J2 J1
5 3 4 2 1
J3
J2
J4J3
2
J1
COM D COM
3
2
F1
Vcc
D
D
EOL
DISABLED
EOL
DISABLED
3
1
RS-485
SIDE B
J3
TX
A - B
FAULT
B
1
TX
B - A
BAUD
RATE
G W
L2 G
FAULT
A
AC (HI)
FUSE 3AG
0.5A, 250V
Status
LEDs
Status
LEDs
1200 OHMS
PWR
220 OHMS
1200 OHMS
JUMPER PAIR
(ONE SIDE)
EOL
ENABLED
EOL Jumpers
Side B (OUT)
EOL
ENABLED
EOL Jumpers
Side A (IN)
GROUND
L1
L1
RS-485
SIDE A
EOL JUMPERS
EQUIVALENT CIRCUIT
(4683 UNITS ONLY)
AC (LO)
NETWORK CONNECTIONS
REMOVE THIS SCREW ON EACH
SIDE TO REMOVE COVER
Baud Rate
Switches
G COM HOT
1 - 600
2 - 1200
3 - 2400
4 - 4800
5 - 9600
6 - 19.2K
7 - 38.4K
8 - 76.8K
MODEL 4683-TTM-1F REPEATER
MODEL 4683-TTM-2F REPEATER
MODEL 4683-TTM-3F REPEATER
End-of-Line (EOL) Termination Jumper Locations.
Input Power Fuse Location.
RS-485
SIDE B
24V DC
RTN
COM
D
D
D
R T
R T
_
24V DC
RS-485
SIDE A
COM
D
R T
R T
_
NC
4683-TTM-1F (115VAC)
4683-TTM-2F (230VAC)
4683-TTM-3F (24VAC)
NOTE:
-3F 24V AC units do not require a
separate transformer. 24V AC power
from the RS-485 devices may be used.
T
2 1
S1
5 4 3 8 7 6
T
T
D
D
NC
R
R
D
COM
RTN
24VDC
4.30
2.10
TYP
0.30
3.70
BAUD
RATE
T
(53.34)
(7.62)
(93.98) acromag
FAULT
A
6.40
7.0
R
R
RS-485
SIDE A
TX
B - A
COM
RS-485
SIDE B
FAULT
B
TX
A - B
D
24VDC
(177.80)
TYP
0.30
POWER
(109.22)
(162.56) (7.62)
1 - 600
2 - 1200
3 - 2400
4 - 4800
5 - 9600
6 - 19.2K
7 - 38.4K
8 - 76.8K
Switch Variation Switch Operation
Slide Switch Slide with arrow
to turn ON.
Slide opposite to
arrow to turn Off.
Toggle Switch Depress toward
numbers to turn
On (Closed).
Depress toward
OPEN to turn Off.
248-295-0880 ■ 248-624-9234 ■ ■ ■ 30765 Wixom Rd, Wixom, MI 48393 USA
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 9/2013
Network Accessories: 4683 Series
4683-TTM RS-485 to RS-485 Network Repeater
Performance Specifications
■ Communication Specifications
Baud Rates
Switch settings on unit for 600, 1200, 2400, 4800,
9600, 19.2K, 38.4K, and 76.8K baud rates. Switch
must be in the proper baud rate position for proper
operation.
RS-485 Bus Loading
One unit load equivalent.
RS-485 Bus Drive
Complete RS-485 compliance for up to 32 unit loads
(31 unit loads if a repeater is used).
End-of-Line Termination Network
The EOLN termination network
is shown on the right and is
individually selected on both
the A and B sides by a pair of
shorting clips. The A-side is
controlled by jumper pair J1, J2
and the B-side is controlled by
jumper pair J3 and J4.
The EOLN termination network
is enabled for the A side or B
side when the associated pair
of jumpers are positioned over
pins 1 and 2. Conversely, the EOLN is disabled (out of
the circuit) when the pair jumpers are positioned over
pins 2 and 3.
Duplex
Half duplex only.
Data Format
Ten bits typical (1 start bit, 8 data bits, and 1 stop bit).
Other formats are supported.
■ Specifications
Power Line Fuse
0.5A, 125V, 0.75A, 3AG type.
Isolation
Provides galvanic and opto-coupler isolation between
RS-485(A), RS-485(B), AC power, and chassis ground.
Common mode voltages are permitted up to 250V
rms or 354V DC (withstands a 1500V AC dielectric
strength test for 1 min. without breakdown) on a
continuous basis. Complies with requirements outlined
in ANSI C39.5-1974 for voltage ratings specificed.
RFI Resistance
Withstands an RFI field strength of 10V per meter at
27 Mhz, 151 Mhz, and 467 Mhz with no digital effect,
per SAMA PMC 33.1.
Line Noise Effects
Field and power line terminals withstand ANSI/IEEE
C37.90-1978 Surge Withstanding Capability (SWC)
Test with no component
failures. Unit is tested to a standardized test
waveform that is representative of surges
(high-frequency transient electrical interference),
observed in actual installations.
Communications Connections
Network repeater - both RS-485 connectors use
modular terminal blocks with screw clamps. Wire
range 14 to 26 AWG.
Power Wire Connections
Network repeater terminal block. See label on unit for
power to be applied to unit.
Shipping Weight
3.0 pounds (1.4 kg) packed per unit.
■ Environmental
Operating temperature
-25 to 70° C (-13 to 158° F)
Storage temperature
-25 to +85° C (-13 to 185° F)
Relative humidity
0 to 95% RH (noncondensing),
up to 40° C (104° F).
Power
4683-TTM-1F
115VAC ±10%, 50/60 Hz, 0.05A
4683-TTM-2F
230VAC ±10%, 50/60 Hz, 0.03A
4683-TTM-3F
24VAC ±10%, 50/60 Hz, 0.18A typical
Approvals
UL/cUL listed – energy management equipment.
Ordering Information
Models
4683-TTM-1F
115V ACPower.
4683-TTM-2F
230V ACPower.
4683-TTM-3F
24V ACPower.
Accessories
See for more information.
3 2 1
D
3 2 1
D
1200
Ohms
1200
Ohms
220
Ohms
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
Bulletin #8400-568b
Description
Acromag’s configuration software is the key
to the I/O modules’ easy-to-use operation.
The software employs the friendly Windows ?
interface with pull-down selection menus and
fill-in-the-blank fields to speed you through a
few brief configuration screens. No programming
is required.
This package includes the Configuration
Software, an RS232-to-485 Serial Port Converter,
RS485 Signal Cable, and an USB to Serial
adapter. These components provide everything
you need to set up a Series 900 I/O module
from your desktop PC before installing it on the
network.
Software Compatibility
Windows XP, Vista, 7.
Ordering Information
NOTE: For more information, visit .
Models
900C-SIP
Configuration Software Interface Package. Includes
user manual, CD, non-isolated RS232-to-RS485 serial
port converter (5034-214), RS485 cable (5034-202),
and USB adapter (4001-095).
4001-095
USB-to-DB9 serial port (RS232) adapter.
5034-186
Configuration software on CD-ROM.
5034-202
RS485 to 3-wire cable converter and cable, DB-9M to
3 x 12AWG RS485 cable, 8 ft.
5034-214
Non-isolated RS232-to-RS485 serial port converter,
RS232 port-powered, DB-9F to DB-9F.
Connection Diagram
See following page.
Configuration Software ◆ USB-to-RS232 Adapter ◆ RS232-to-RS485 Adapter ◆ Interface Cable
Model 900C-SIP Configuration Software Interface Package
Series 900MB Modbus RTU I/O
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2009. Data subject to change without notice. Printed in USA 6/2010.
Series 900MB Modbus RTU I/O
RS-232
RS-485
900C-SIP COMMUNICATION CONNECTIONS
6 FEET OF CABLE
USB MALE
DB9 MALE
RS232
USB SERIAL CONVERTER 4001-095
LED
TO HOST USB PORT
OR
HOST
USB
TO HOST RS232 SERIAL PORT
HOST
RS232
DB9
MALE
HOST RS232 SERIAL
PORT CONNECTOR OR
USB CONNECTOR AT
BACK OF PC
CONNECT THE RS232
SIDE OF CONVERTER
TO THE PC
CONNECT THE RS485
SIDE OF CONVERTER
TO THE CABLE
RS232 TO RS485 SERIAL
CONVERTER
(MODEL 5034-214)
DB9 FEMALE DB9 FEMALE
PC RUNNING
ACROMAG
MODBUS CONFIG
SOFTWARE
INSTALL MODBUS CONFIGURATION SOFTWARE
WINDOWS-BASED PERSONAL COMPUTER
THE RS232-to-RS45 PORT-POWERED CONVERTER 5034-214
IS INTENDED FOR CONFIGURATION PURPOSES FOR ONE
DEVICE. IT IS NOT SUITABLE FOR DRIVING A FULLY LOADED
RS485 NETWORK. THE USE OF AN EXTERNALLY POWERED
RS485 CONVERTER IS RECOMMENDED FOR DRIVING MULTIPLE
DEVICES OF AN RS485 NETWORK.
2
0
R
ST
TB1
12
45 44
15
42 41
TB2
23
34
B
C
26
31
DFT
D
D D
A
B
A
TB4
TB3
3
1
RUN
11 13 14
46 43
22 21
36 35
25
32
TB1
Acromag
RS-232
TB1
RS485
TB4
COM
A
TB2
PWR
B
TB3
RS-485
RED
COM
D
D
RS-485
TB4
COM
COM
16 24
33
5034-202
STATUS LED (YELLOW)
RUN/PWR LED (GREEN)
D
C
WIRE
CABLE 5034-202
ANY 900MB MODULE
GREEN
BLACK
CONNECT WIRES AS SHOWN
COLOR
ANY 900MB MODULE
CONNECT THE RS232
SIDE OF CONVERTER
TO THE PC
CONNECT THE RS485
SIDE OF CONVERTER
TO THE CABLE
RS232 TO RS485 SERIAL
CONVERTER
(MODEL 5034-214)
CAUTION: DO NOT CONNECT THE
CABLE DIRECTLY TO THE PC WITHOUT
THE CONVERTER, OR DAMAGE TO
THE MODULE MAY RESULT.
DEFAULT MODE SWITCH -
PUSH FOR DEFAULT MODE
STATUS LED FLASHES IN
DEFAULT MODE
REFER TO THE USER'S MANUAL
THAT CAME WITH YOUR MODULE
TO COMPLETE THE MODULE'S
POWER AND I/O CONNECTIONS
DB9 MALE
DB9 FEMALE DB9 FEMALE
BusWorks ? I/O Modules
for Profibus-DP
Acromag’s BusWorks 900PB series is a
high-performance line of network-ready
analog and discrete I/O modules. They
feature universal input/output ranges and
an inligent microcontroller to provide
extreme flexibility and powerful monitor-
ing and control capabilities. Select from a
variety of analog and discrete I/O models
to meet your application requirements.
Each module provides a direct network
interface for your I/O signals. Unlike
“block I/O” devices that combine large,
expensive processor blocks with snap-on
I/O terminal blocks, 900PB modules
handle the network interface and I/O
processing in one, compact multi-channel
module. This space-saving approach is
very cost-effective for systems that need
to add a small quantity of I/O channels at
existing control sites or network to new
remote sites.
To ensure high performance, modules
feature an advanced microcontroller
technology. On-board address switches
and automatic baud rate detection (up
to 12 Mbps) simplify installation. Four-
way isolation prevents ground loops and
increases noise immunity. Indicator LEDs
and self-diagnostics help you quickly
catch problems.
Inputs
? Thermocouple ? DC current/voltage
? RTD/resistance ? AC current
? Millivolt ? Discrete level/status
Outputs
? DC voltage
? DC current
? Discrete switches
Power
? 12-36V DC
Approvals
? Profibus PNO, CE, UL/cUL Class I Div 2
For more information, visit our website at
/profibus
12
Save up to 50%
compared to block
and modular I/O
systems. Acromag’s
BusWorks ? modules
do not require special
buscouplers, racks, or
power supplies.
Call 877-214-6267 or 248-295-0880 for technical assistance.
PROFIBUS-DP: REMOTE I/O
961PB, 962PB
Analog Input:
6-Channel
Differential Input:
DC Current or
DC Voltage Signals
Models
961PB: 6 DC current input channels
962PB: 6 DC voltage input channels
I Description
These modules provide an isolated Profibus-DP
network interface for six analog input channels.
Differential inputs eliminate ground loops and
thus the need for isolators in many applications.
Multi-range inputs accept signals from a variety of
sensor and devices. High-resolution, low noise,
A/D converters deliver high accuracy and reliability.
Input Ranges
DC Current (user-selectable ranges)
0 to 1mA, 0 to 11mA, 0 to 20mA, 4 to 20mA
0 to 20 amps AC (with optional AC sensor)
DC Voltage (user-selectable ranges)
±78mV to ±10V DC (eight range options)
Network Communication
Profibus-DP, RS-485 network up to 12Mbaud
Power Requirement
12 to 36V DC supply required
Approvals
Profibus PNO certified.
CE marked. UL, cUL listed.
Class I; Division 2; Groups A, B, C, D.
I Special Features
I Standard Profibus-DP network communication
with industry-standard ASIC (Siemens SPC3)
I 6-input stand-alone module is very economical
I Differential inputs eliminate ground loops
I Universal inputs support a variety of sensors
I High-resolution 16-bit Σ?? A/D converters
ensure precise, high accuracy measurements
I Compact packaging with pluggable terminals
saves space and simplifies wiring
I Wide operational temperature range permits
installation in extreme environments
I Performance
I General Specifications
See Page 47 for communication and other specs.
I Input
Configuration
Input ranges are selectable for a 3-channel group.
Accuracy
Better than ±0.05% of span for nominal input ranges.
Analog to Digital Converter (A/D)
16-bit Σ?? converter.
Resolution
0.005% or 1 part in 20000.
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 140dB @ 60Hz.
Input Filter Bandwidth
-3dB at 3Hz, typical.
DC Current Input impedance
24.9 ohms.
DC Voltage Input impedance
Greater than 110.5K ohms.
I Environmental
Ambient Temperature
Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative Humidity
5 to 95%, non-condensing.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power.
I Ordering Info
Models
961PB-2006
DC current input module, 6 differential channels
962PB-2006
DC voltage input module, 6 differential channels
NOTE: Modules include GSD files on CD-ROM.
Accessories (see Page 48)
5020-350
AC current sensor. Used with 961PB DC current input
models. One sensor per channel is required.
See page 205.
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
TBK-B03
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S03
Optional terminal block kit, spring clamp style, 4 pcs.
Profibus I/O BusWorks ?
41
9 0 0 P B S e r i e s
Profibus-DP / RS485
L
C
PROFIBUS
RUN BUS
Acromag
2.34
(59.4)
1.05
(26.7)
NOTE: Dimensions Are INCHES (MILLIMETERS).
3.75
(95.3)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
4.68
(118.9)
46
IN5-
45
IN5+
IN0-
43
IN4+
IN1+
42
TB4
TB2
IN2+
IN3+
IN3-
11 12 14 15 22 23 25 26
TB3
TB1
TB1
IN0+
IN1-
44 41
TB2
IN2-
TB3
13 16
IN4-
21 24
INPUTS 0, 1
TB4
INPUTS 4, 5
4.35
(110.5)
3.90
(99.1)
DC-
32
DC+
31 33 LSD MSD
PWR
SLAVE
ADDRESS
(HEX)
INPUTS 2, 3
Profibus I/O BusWorks ?
963/964PB
Analog Input:
12-Channel
Single-Ended Input:
DC Current or
DC Voltage Signals
Models
963PB: 12 DC current input channels
964PB: 12 DC voltage input channels
I Description
These modules provide an isolated Profibus-DP
network interface for twelve analog input chan-
nels. Compact design saves space and lowers
system costs. Multi-range inputs accept signals
from a variety of sensors and devices. High-
resolution, low noise, A/D converters deliver
high accuracy and reliability.
Input Ranges
DC Current (user-selectable ranges)
0 to 1mA, 0 to 11mA, 0 to 20mA, 4 to 20mA
0 to 20 amps AC (with optional AC sensor)
DC Voltage (user-selectable ranges)
±1V, ±5V, or ±10V DC
Network Communication
Profibus-DP, RS-485 network up to 12Mbaud
Power Requirement
12 to 36V DC supply required
Approvals
Profibus PNO certified.
CE marked. UL, cUL listed.
Class I; Division 2; Groups A, B, C, D.
I Special Features
I Standard Profibus-DP network communication
with industry-standard ASIC (Siemens SPC3)
I 12-input module has very low cost per channel
I Universal DC inputs support a wide variety of
industrial sensors and signals
I High-resolution 16-bit Σ?? A/D converters
ensure precise, high accuracy measurements
I Compact packaging with pluggable terminals
saves space and simplifies wiring
I Wide operational temperature range permits
installation in extreme environments
I Performance
I General Specifications
See Page 47 for communication and other specs.
I Input
Configuration
Input ranges are selectable on each terminal block for
a group of four input channels (4-channel basis).
Accuracy
Better than ±0.05% of span for nominal input ranges.
Analog to Digital Converter (A/D)
16-bit Σ?? converter.
Resolution
0.005% or 1 part in 20000, typical.
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 140dB @ 60Hz.
Input Filter Bandwidth
-3dB at 3Hz, typical.
DC Current Input impedance
49.9 ohms.
DC Voltage Input impedance
Greater than 110.5K ohms.
I Environmental
Ambient Temperature
Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative Humidity
5 to 95%, non-condensing.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power.
Inputs share a common.
I Ordering Info
Models
963PB-2012
DC current input module, 12 single-ended channels
964PB-2012
DC voltage input module, 12 single-ended channels
NOTE: Modules include GSD files on CD-ROM.
Accessories
5020-350
AC current sensor. Used with 963PB DC current input
models. One sensor per channel is required.
See page 205.
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
TBK-B03
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S03
Optional terminal block kit, spring clamp style, 4 pcs.
42
9 0 0 P B S e r i e s
Profibus-DP / RS485
L
C
PROFIBUS
RUN BUS
Acromag
2.34
(59.4)
1.05
(26.7)
NOTE: Dimensions Are INCHES (MILLIMETERS).
3.75
(95.3)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
4.68
(118.9)
IN00
46
RTN
IN01
45
IN11
IN02
43
RTN
IN03
42
IN09
TB4
TB2
IN05
RTN
IN07 DC-
32
RTN DC+
31
11 12 14 15 22 23 25 26
TB3
TB1
TB1
RTN
RTN
44 41
TB2
IN04
IN06
33 LSD MSD
TB3
13 16
IN10
IN08
21 24
ANALOG INPUTS: 4-7 ANALOG INPUTS: 0-3
TB4
PWR ANALOG INPUTS: 8-11
4.35
(110.5)
3.90
(99.1)
SLAVE
ADDRESS
(HEX)
Profibus I/O BusWorks ?
965PB
Analog Input:
4 or 6-Channel Input:
Thermocouple or
Millivolt Signals
I Description
These modules provide an isolated Profibus-DP
network interface for up to six input channels.
Differential inputs eliminate ground noise and
each terminal block includes a cold junction
compensation (CJC) sensor for more precise
temperature measurements. Multi-range inputs
accept signals from a variety of sensors and
devices. High-resolution, low noise, A/D
converters deliver high accuracy and reliability.
Input Ranges
Thermocouple (user-selectable type)
Type J, K, T, R, S, E, B, or N
DC Millivolts (user-selectable range)
±100mV or ±1V DC
Network Communication
Profibus-DP, RS-485 network up to 12Mbaud
Power Requirement
12 to 36V DC supply required
Approvals
Profibus PNO certified.
CE marked. UL, cUL listed.
Class I; Division 2; Groups A, B, C, D.
I Special Features
I Standard Profibus-DP network communication
with industry-standard ASIC (Siemens SPC3)
I 6-input stand-alone module is very economical
I Universal inputs support a variety of sensors
I Built-in CJC sensor on each terminal block pro-
duces more precise temperature measurements
I Thermocouple break detection (upscale or
downscale) identifies sensor wiring failures
I High-resolution 16-bit Σ?? A/D converters
ensure precise, high accuracy measurements
I Compact packaging with pluggable terminals
saves space and simplifies wiring
I Wide operational temperature range permits
installation in extreme environments
I Performance
I General Specifications
See Page 47 for communication and other specs.
I Input
Configuration
Input ranges are selectable for a 3-channel group.
Accuracy
Input Input Range Accuracy (typical)
Type J -210 to 760°C ±0.5°C
Type K -200 to 1372°C ±0.5°C
Type T -260 to 400°C ±0.5°C
Type R -50 to 1768°C ±1.0°C
Type S -50 to 1768°C ±1.0°C
Type E -200 to 1000°C ±0.5°C
Type B 260 to 1820°C ±1.0°C
Type N -230 to -170°C ±1.0°C
Type N -170 to 1300°C ±0.5°C
Voltage ±100mV or ±1V DC ±0.1% of span
Cold Junction Compensation (CJC) Accuracy
±0.5°C.
Thermocouple Break Detection
Upscale or downscale selection applies to all channels.
Analog to Digital Converter (A/D)
16-bit Σ?? converter.
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 140dB @ 60Hz.
Input Filter Bandwidth
-3dB at 3Hz, typical.
I Environmental
Ambient Temperature
Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative Humidity
5 to 95%, non-condensing.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power.
I Ordering Info
Models
965PB-2004
4-channel thermocouple/millivolt input module
965PB-2006
6-channel thermocouple/millivolt input module
NOTE: Modules include GSD files on CD-ROM.
Accessories (see Page 48)
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
43
9 0 0 P B S e r i e s
Profibus-DP / RS485
L
C
PROFIBUS
RUN BUS
Acromag
2.34
(59.4)
1.05
(26.7)
NOTE: Dimensions Are INCHES (MILLIMETERS).
3.75
(95.3)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
4.68
(118.9)
46
IN5-
45
IN5+
IN0-
43
IN4+
IN1+
42
TB4
TB2
IN2+
IN3+
IN3-
11 12 14 15 22 23 25 26
TB3
TB1
TB1
IN0+
IN1-
44 41
TB2
IN2-
TB3
13 16
IN4-
21 24
CJC-0 INPUTS 0, 1
TB4
INPUTS 4, 5 CJC-2
4.35
(110.5)
3.90
(99.1)
DC-
32
DC+
31 33 LSD MSD
PWR
SLAVE
ADDRESS
(HEX)
(Model 965PB-2006 only)
CJC-1 INPUTS 2, 3
Profibus I/O BusWorks ?
966PB
Analog Input:
4 or 6-Channel Input:
RTD or Resistance
Signals
I Description
These modules provide an isolated Profibus-DP
network interface for up to six input channels.
Multi-range inputs accept signals from a variety
of sensors and devices. High-resolution, low
noise, A/D converters deliver high accuracy and
reliability. 3-way isolation further improves the
system performance.
Input Ranges
RTD (user-selectable type)
2-wire and 3-wire RTDs are supported.
Platinum 100 ohm (alpha = 1.3850 or 1.3911)
Nickel 120 ohm
Copper 10 ohm
Resistance
0 to 500 ohms
Network Communication
Profibus-DP, RS-485 network up to 12Mbaud
Power Requirement
12 to 36V DC supply required
Approvals
Profibus PNO certified.
CE marked. UL, cUL listed.
Class I; Division 2; Groups A, B, C, D.
I Special Features
I Standard Profibus-DP network communication
with industry-standard ASIC (Siemens SPC3)
I 6-input stand-alone module has much lower
start-up cost than multi-piece block I/O systems
I Versatile RTD or ohmic inputs support a wide
variety of industrial sensors and devices
I RTD break detection (upscale or downscale)
identifies sensor wiring failures
I High-resolution 16-bit Σ?? A/D converters
ensure precise, high accuracy measurements
I Compact packaging with pluggable terminals
saves space and simplifies wiring
I Wide operational temperature range permits
installation in extreme environments
I Performance
I General Specifications
See Page 47 for communication and other specs.
I Input
Configuration
Input ranges are selectable for a 3-channel group.
Accuracy
Input Type Input Range Accuracy (typical)
Pt 100 ohm -200 to 850°C ±0.25°C
Ni 120 ohm -80 to 320°C ±0.25°C
Cu 10 ohm -200 to 260°C ±1.25°C
Resistance 0 to 500 ohms ±0.05 ohms
RTD Break Detection
Upscale or downscale selection applies to all channels.
Analog to Digital Converter (A/D)
16-bit Σ?? converter.
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 130dB @ 60Hz.
Input Filter Bandwidth
-3dB at 3Hz, typical.
Excitation Current
1mA DC typical, all RTD types.
I Environmental
Ambient Temperature
Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative Humidity
5 to 95%, non-condensing.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power.
Inputs share a common.
I Ordering Info
Models
966PB-2004
4-channel RTD/resistance input module
966PB-2006
6-channel RTD/resistance input module
NOTE: Modules include GSD files on CD-ROM.
Accessories (see Page 48)
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
TBK-B03
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S03
Optional terminal block kit, spring clamp style, 4 pcs.
44
9 0 0 P B S e r i e s
Profibus-DP / RS485
L
C
PROFIBUS
RUN BUS
Acromag
2.34
(59.4)
1.05
(26.7)
NOTE: Dimensions Are INCHES (MILLIMETERS).
3.75
(95.3)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
4.68
(118.9)
46
IN5L
45
IN5-
IN1+
43
IN4L
IN1-
42
TB4
TB2
IN2L
IN3-
IN3L
11 12 14 15 22 23 25 26
TB3
TB1
TB1
IN0L
IN1L
44 41
TB2
IN3+
TB3
13 16
IN5+
21 24
RTD INPUTS 0, 1
TB4
RTD INPUTS 4, 5
4.35
(110.5)
3.90
(99.1)
DC-
32
DC+
31 33 LSD MSD
PWR
SLAVE
ADDRESS
(HEX)
RTD INPUTS 2, 3
(966PB-2006 only)
IN4-
IN4+
LRTN
IN0-
IN0+
IN2-
IN2+
Profibus I/O BusWorks ?
972/973PB
Analog Output:
4 or 6-Channel Output:
DC Current or
DC Voltage Signals
Models
972PB: DC current output channels
973PB: DC voltage output channels
I Description
These modules provide up to six channels of
analog output. Multi-range outputs support a
wide variety of industrial devices. They can drive
displays and recorders, control drives, or send
analog signals to other systems. High-resolution,
low noise, D/A converters deliver high accuracy
and reliability. 3-way isolation further improves
system performance.
Output Ranges
DC Current (user-selectable ranges)
0 to 1mA, 0 to 20mA, or 4 to 20mA
DC Voltage (user-selectable ranges)
0 to 1V, 0 to 5V, or 0 to 10V DC
Network Communication
Profibus-DP, RS-485 network up to 12Mbaud
Power Requirement
16 to 36V DC supply required
Approvals
Profibus PNO certified.
CE marked. UL, cUL listed.
Class I; Division 2; Groups A, B, C, D.
I Special Features
I Standard Profibus-DP network communication
with industry-standard ASIC (Siemens SPC3)
I 6-input stand-alone module has much lower
start-up cost than multi-piece block I/O systems
I Universal DC outputs support a wide variety of
signals and industrial devices
I Three selectable failsafe modes (0%, last-state,
or pre-defined) help prevent unsafe conditions
I Compact packaging with pluggable terminals
saves space and simplifies wiring
I Wide operational temperature range permits
installation in extreme environments
I Performance
I General Specifications
See Page 47 for communication and other specs.
Configuration
Output ranges are selectable on a channel to channel
basis.
I Output
Accuracy
Better than ±0.1% of span, typical.
1.6% for 0 to 1mA range. 0.8% for 0 to 1V range.
Digital to Analog Converter (D/A)
12-bit converter.
Current Output Compliance
12V minimum, 13V typical.
Current Output Load Resistance Range
0 to 625 ohms, typical.
Voltage Output Source Current
0 to 10mA DC, maximum.
I Environmental
Ambient Temperature
Operating:
972PB-200x models -25 to 60°C (-13 to 158°F).
973PB-200x models: -25 to 70°C (-13 to 140°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative Humidity
5 to 95%, non-condensing.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power.
Outputs share a common.
I Ordering Info
Models
972PB-2004
DC current output module, 4 channels
972PB-2006
DC current output module, 6 channels
973PB-2004
DC voltage output module, 4 channels
973PB-2006
DC voltage output module, 6 channels
NOTE: Modules include GSD files on CD-ROM.
Accessories (see Page 48)
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
TBK-B03
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S03
Optional terminal block kit, spring clamp style, 4 pcs.
45
9 0 0 P B S e r i e s
Profibus-DP / RS485
L
C
PROFIBUS
RUN BUS
Acromag
2.34
(59.4)
1.05
(26.7)
NOTE: Dimensions Are INCHES (MILLIMETERS).
3.75
(95.3)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
4.68
(118.9)
RTN
V2+
TB2
RTN
11 12 14 15 22 23 25 26
TB3
TB1
TB1
V1+
RTN
TB2
RTN
TB3
13 16 21 24
ANALOG OUTPUTS
4.35
(110.5)
3.90
(99.1)
DC-
32
DC+
31 33 LSD MSD
PWR
SLAVE
ADDRESS
(HEX)
ANALOG OUTPUTS
RTN
V0+
RTN
V3+
Profibus I/O BusWorks ?
981/982/983PB
Discrete I/O:
12-Channel I/O:
Active-Low Inputs,
Sinking Outputs
(Low-Side Switching)
Models
981PB: 12 input channels
982PB: 12 output channels
983PB: 12 input/output channels
I Description
These modules provide an isolated Profibus-DP
network interface for twelve discrete input
and/or output channels. The outputs provide
direct on/off, high/low, or open/close control of
industrial devices. The inputs sense the status of
motors, pumps, valves and other equipment. The
983PB model with tandem I/O provides output
level control and status verification in one unit.
Input Range
0 to 35V DC
Output Range
0 to 35V DC
Network Communication
Profibus-DP, RS-485 network up to 12Mbaud
Power Requirement
12 to 36V DC supply required
Approvals
Profibus PNO certified.
CE marked. UL, cUL listed.
Class I; Division 2; Groups A, B, C, D.
I Special Features
I Standard Profibus-DP network communication
with industry-standard ASIC (Siemens SPC3)
I 12-channel stand-alone module has far lower
start-up cost than multi-piece block I/O systems
I 0-35V DC solid-state logic interface can
monitor or control a wide variety of devices
I Bidirectional I/O models facilitate loopback
monitoring of the output state
I Socketed SIP resistors provide input and output
5.6K ohm pull-ups to the excitation supply
I Three selectable failsafe modes (off, last-state,
or pre-defined) help prevent unsafe conditions
I Compact packaging with pluggable terminals
saves space and simplifies wiring
I Wide operational temperature range permits
installation in extreme environments
I Performance
I General Specifications
See Page 47 for communication and other specs.
I Input (981 & 983 models)
Input Type
Twelve active-low, buffered inputs, with a common
connection. Built-in 5.6K ohm pullups to excitation
terminal socketed for 4-channel groups.
Input Signal Voltage Range
0 to 35V DC, maximum.
Input Impedance
100K ohms, typical.
Input Signal Threshold
TTL compatible with 100mV of hysteresis, typical.
I Output (982 & 983 models)
Output Type
12 independent, open-drain, DMOS MOSFET switches.
Output Voltage Range
0 to 35V DC max. (0 to 500mA/channel continuous).
Output ON Resistance
0.28 ohms maximum.
I Environmental
Ambient Temperature
Operating: -25 to 70°C (-13 to 158F).
Storage: -40 to 85°C (-40 to 185°F).
Relative Humidity
5 to 95%, non-condensing.
Isolation
1500V AC for 60 seconds or 250V AC continuous.
3-way isolation between I/O, network, and power.
I Ordering
Information
Models
981PB-2012
Discrete input module, 12 channels
982PB-2012
Discrete output module, 12 channels
983PB-2012
Discrete input/output module, 12 channels
NOTE: Modules include GSD files on CD-ROM.
Accessories (see Page 48)
PS5R-D24
Power supply (24V DC, 2.1A).
See Power Supplies on Page 199.
TBK-B03
Optional terminal block kit, barrier strip style, 4 pcs.
TBK-S03
Optional terminal block kit, spring clamp style, 4 pcs.
46
9 0 0 P B S e r i e s
Profibus-DP / RS485
L
9 8
5 4
1 0
11
7 6
3 2
C
PROFIBUS
10
RUN BUS
Acromag
2.34
(59.4)
1.05
(26.7)
CH. I/O STATUS
NOTE: Dimensions Are INCHES (MILLIMETERS).
3.75
(95.3)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
4.68
(118.9)
EXC1
46
RTN
CH 0
45
CH11
CH 2
43
CH 9
CH 3
42
CH 8
TB4
TB2
CH 4
CH 5
CH 7
RTN
11 12 14 15 22 23 25 26
TB3
TB1
TB1
CH 1
RTN
44 41
TB2
EXC2
CH 6
TB3
13 16
CH10
EXC3
21 24
DIGITAL IN or OUT DIGITAL IN or OUT
TB4
DIGITAL IN or OUT
4.35
(110.5)
3.90
(99.1)
DC-
32
DC+
31 33 LSD MSD
PWR
SLAVE
ADDRESS
(HEX)
Profibus I/O BusWorks ?
The following specifications are common to all
900PB Series I/O modules.
I Communication
Interface Standard
Isolated, 3-wire RS-485 multi-drop, half-duplex,
asynchronous.
Command/Response Protocol
Standard ProfiBus DP (Master/Slave) protocol per
European Norm EN50170.
Baud Rate
Supports rates of 9600, 19.2K, 44.45K, 93.75K, 187.5K,
500K, 1.5M, and 12M bits per second, auto-detected.
Communication Distance
Up to 1200 meters without a repeater using Type A
wire (<30pF/m).
1200m @ 115Kbps or less
1000m @ 187.5Kbps
400m @ 500Kbps
200m @ 1.5Mbps
100m @ 12Mbps
Address
Set via two rotary hexadecimal switches or via the Set
Slave Address command. Valid setting is 0-125.
Address 126 (7EH) is factory default address.
Maximum Message Size
Up to 32 bytes recommended, extendable up to 244
bytes of data/node/message, plus 11 bytes of over-
head (data frame).
Network Capacity
Multi-drop up to 31 modules, plus a host, without a
repeater. Up to 125 modules plus a host if four
repeaters are used (one for every 31 nodes).
I Environmental
Isolation
I/O channel, power, and network circuits are isolated
from each other for common-mode voltages up to
250VAC, or 354V DC off DC power ground, on a
continuous basis (will withstand 1500VAC dielectric
strength test for one minute without breakdown).
Complies with test requirements of ANSI/ISA-82.01-
1988 for voltage rating specified.
I Electromagnetic
Compatibility (EMC)
Immunity per European Norm EN50082-1.
Emissions per European Norm EN50081-1.
Electrostatic Discharge (ESD) Immunity
Per EN61000-4-2.
Radiated Field Immunity (RFI)
Per EN61000-4-3 and ENV50204.
Electrical Fast Transient Immunity (EFT)
Per EN61000-4-4.
Conducted RF Immunity (CRFI)
Per EN61000-4-6.
Surge Immunity
Per EN61000-4-5.
Radiated Frequency Emissions
Per EN55022 Class B.
47
9 0 0 P B S e r i e s
on
off
RUN RUN BUS
RUN BUS
on
BUS
on
off
BUS
on
RUN
on
off
RUN
off off
500Kbps
19.2Kbps
400M
1200M
NODE 32'
PROFIBUS
BUS
on
off
PROFIBUS
on
RUN
PROFIBUS
RUN
BUS
PROFIBUS
BUS
12Mbps
9600bps
93.75Kbps
187.5Kbps
100M
1200M
1000M
1200M
RS485 SIGNAL
REPEATER
off
1
PROFIBUS PROFIBUS PROFIBUS
1.5Mbps
BAUD
200M
LENGTH
61
NODE 2'
NODE 5 NODE 31
NETWORK LENGTH PER
BAUD RATE w/ TYPE A
PROFIBUS CABLE
END OF NETWORK
(TERMINATION ON)
TERMINATION
SWITCH
NODE 2
NODE 1
START OF NETWORK
(TERMINATION REQD)
PROFIBUS MASTER
PLUG-IN CARD
INSTALLED IN PC.
START OF SEGMENT
(TERMINATION ON)
NODE 32 NODE 1'
2
NODE 4 NODE 3
3
31
SEGMENT 2 (UP TO 1200 METERS,
UP TO 32 NODES PER SEGMENT)
4 30
SEGMENT 1 (UP TO 1200 METERS, UP TO 32 NODES PER SEGMENT)
END OF SEGMENT
(TERMINATION ON)
NOTE: THE PROFIBUS CONNECTORS SHOWN HAVE
A TERMINATION NETWORK BUILT-IN. WITH
TERMINATION ON, THE OUTGOING CABLE IS
DISCONNECTED FROM NETWORK. SWITCH
TERMINATION ON ONLY AT THE BEGINNING AND
END OF A NETWORK OR NETWORK SEGMENT.
PROFIBUS MASTER - A
HOST PC WITH PROFIBUS
CARD INSTALLED AND
RUNNING APPLICATION
SOFTWARE.
PROFIBUS RS485 NETWORK
A network segment may contain up to 32 nodes without the use of a signal repeater.
Transmission distance is up to 1200 meters per segment without a repeater.
A 120 ohm termination resistor must be placed at both ends of a network or network-segment.
The total number of nodes and total distance may be extended by using signal repeater(s).
The maximum number of modules possible is further limited by the address range from 0 to 125.
General Operation and Performance Specifications
Profibus I/O BusWorks ?
Accessories
48
9 0 0 P B S e r i e s
I Ordering Information
5020-350
AC current sensor (See page 205)
Barrier strip (left) and spring clamp (right).
I Ordering Information
See individual I/O modules for compatibility.
Terminal Blocks
AC Current Sensor
50W Supply
Input Power Requirement
85 to 264V AC or 105 to 370V DC
Output
24V DC, 2.1A (50W)
I Ordering Information
PS5R-D24
Universal 50W power supply
See Power Supplies on Page 199 for other models
and more information.
DIN-Rail Mounting
For your convenience, Acromag offers several
mounting accessories to simplify your system
installation. Our 19” rack-mount kit provides a
clean solution for mounting your I/O modules
and a power supply. Or you can buy precut DIN
rail strips for mounting on any flat surface.
I Ordering Information
20RM-16-DIN
19" rack-mount kit with DIN rail.
DIN RAIL 3.0
DIN RAIL 16.7
DIN rail strip, Type T, 3 inches (75mm) or
16.7 inches (425mm)
3-position:
L = 0.66 inches (16.9 mm)
6-position:
L = 1.26 inches (32.3 mm)
Spring Clamp Terminal Blocks
Barrier Strip Terminal Blocks
TBK-B01
Terminal block kit,
two 6-position pieces
TBK-B02
Terminal block kit,
four 6-position pieces
TBK-B03
Terminal block kit,
one 3-position and
three 6-position pieces
3-position: L = 0.87 inches (22.3 mm)
6-position: L = 1.47 inches (37.7 mm)
Wire range:
AWG #12-26
Wire range:
AWG #12-26
Wire range:
AWG #12-26
TBK-S01
Terminal block kit,
two 6-position pieces
TBK-S02
Terminal block kit,
four 6-position pieces
TBK-S03
Terminal block kit,
one 3-position and
three 6-position pieces
Mounting Hardware Power Supplies
600T Series
Isolated Transmitters
611T, 612T . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2
631T, 632T, 633T . . . . . . . . . . . . . . . . . . . . . . . . . . 4
651T, 652T, 653T . . . . . . . . . . . . . . . . . . . . . . . . . . 6
654T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
655T, 656T, 653T . . . . . . . . . . . . . . . . . . . . . . . . . 10
657T, 658T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
670T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Technical Documentation
Dimensions diagrams . . . . . . . . . .see individual units
Application notes . . . . . . . . . . . . . . . . . . . . . Page 16
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
◆ 650T Units (2-wire) ◆ 630T Units (4-wire) ◆ 610T Unites (4-wire)
600T Series Models by Function Guide
610T 630T 650T 670T
Functions
4-20mA isolator x x
Isolated signal converter/transmitter x x
Signal splitter x x
Channel Configurations
Single channel units x x x x
Dual channel units x x x x
Quad channel units x
Splitter (one input, two outputs) x x
Power Configurations
Input loop-powered x
Output loop-powered (2-wire transmitter) x
AC-powered x
DC-powered x x
Inputs
DC voltage input x x
DC current input x x x x
Thermocouple/millivolt input x
RTD/resistance input x
AC current input x
Outputs
DC current x x x x
DC voltage x
Isolation Configurations
Input from output/power x x
Output from input/power x x
3-way (input/output/power) x x
Multi-channel, DC-powered isolated transmitters.
Designed For high-density panel installations.
Multi-channel AC/DC powered isolators. Provides
excitation supply for 2-wire transmitters.
Multi-channel, output loop-powered transmitters with
input isolation. Designed to front-end PLC inputs.
Multi-channel, input loop-powered transmitters with
output isolation. Designed to isolate PLC outputs to
field devices.
◆ 670T Unites (2-wire)
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 1 –
Description
Models
611T: Single I/O channel
612T: Dual I/O channel
These units receive DC current or voltage input
signals, provide isolation, and output proportion-
al DC current or voltage signals . With support for
universal DC I/O ranges, 610T series transmitters
provide a solution for a wide variety of isolation
and signal conversion tasks . The single-channel
611T and dual-channel 612T are ideal for panel
shops and end-users who require a high-density
signal conditioner that can accomodate a broad
range of instrumentation applications .
Installation is fast and simple with Acromag’s
built-in auto-configuration feature . Using your
standard calibrator, the 610T’s internal microcon-
troller automatically senses the input source type
(voltage or current) and selects the optimum per-
formance range for your zero and full-scale input
values . To adjust your output values, simply push
the up or down buttons on the front panel until
you read the desired output signal on your meter .
Both models provide high-voltage isolation
between the input, output and power (3-way) .
On dual channel units, each channel operates
independently, with inputs isolated from each
other, to prevent interaction between channels .
For easy troubleshooting, each channel has diag-
nostic LEDs to identify input over/under range
conditions . An additional status LED indicates the
unit is operating properly or that the front panel
pushbutton lockout feature has been invoked .
Input Ranges
Universal input with automatic configuration
±100mA (self-ranging),
±100V DC (self-ranging),
0 to 20 amps AC (with optional sensor)
Output Ranges
Universal output (user-configured ranges)
0 to 20mA (full range capability),
0 to 10V DC (full range capability)
Power Requirement
10 to 36V DC
Approvals
CE marked . UL, cUL listed .
Key Features & Benefits
■ Universal DC input and output ranges offer
flexibility to fit many applications .
■ Auto-configuration and self-ranging technolo-
gies speed installation without pots, switches,
jumpers, or software .
■ Optical isolation eliminates ground loops,
reduces noise, and blocks transient signals .
■ Push-button calibration simplifies field
adjustments for faster and easier maintenance .
■ Configuration lockout safety feature prevents
tampering and accidental changes .
■ Reverse-acting output capability enables
inverse proportional control signals .
■ Each input channel can drive two outputs
(a voltage and a current output signal) .
■ Dual channel model saves space and reduces
equipment costs .
■ High-resolution S-D A/D converters deliver
superior accuracy for reliable measurements .
DC current or voltage input ◆ Single/dual-channel DC-powered transmitters
611T, 612T Multi-Channel, Universal DC I/O
IN 1
OUT 1
OUT 2
PWR
PLC / DCS 612T
3-way
optical
isolation
V+/I+
RTN
IN 2
V+/I+
RTN
V+/I+
RTN
V+/I+
RTN
DC+
DC –
R LOAD
R LOAD
Input
Input
+
–
+
–
DIN EN 50022, 35mm
"T" RAIL DIN MOUNTING
(59.4)
2.34
C
L
(95.3)
3.75
R
1.05
(26.7)
1.05
(26.7)
NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS)
(118.9)
4.68
(99.1)
3.90
4.35
(110.5)
11 12 13 14 15 16 21 22 23 24 25 26
TB1
TB2
TB1
TB4
34 33 32 31 36 35
OUTPUT 2 OUTPUT 1
43 42 41 46 45 44
612T-0500 only
TB1 TB2
612T-0500
only
RUN
MODE
1
ST
SET
CH
2
TB4 TB3
RTN
V+
I+
RTN
V+
I+
TB3
TB4
DC+
DC-
Power
INPUT 1 INPUT 2
RTN
I+
JMP
JMP
V+
RTN
I+
JMP
JMP
V+
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 2 –
Performance Specifications
◆ General Input
Analog to Digital Converter (ADC)
16-bit S-D A/D converter .
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz .
Common Mode: Better than 100dB @ 60Hz .
Input Overvoltage Protection
Bipolar Transient Voltage Suppressors (TVS) .
◆ DC Current Input
DC Current Input Range
±100mA DC with full range capability .
Minimum recommended span is ±4mA .
DC Current Input Impedance
10 ohms .
DC Current Input Accuracy
Better than ±0 .1% of output span .
◆ DC Voltage Input
DC Voltage Input Range
±100V DC with full range capability .
Minimum recommended span is ±40mV .
Input impedance
±1V to ±100V input: greater than 100K ohms .
±40mV to ±1V input: 1K ohm
DC Voltage Input Accuracy
Better than ±0 .1% of output span .
◆ AC Current Input
AC Current Input Range (optional)
An optional external AC current sensor is required to
monitor AC current signals (Model 5020-350) .
AC Current Range Primary Turns
0 to 20A AC 1
0 to 10A AC 2
0 to 5A AC 4
0 to 2A AC 10
0 to 1A AC 20
AC Current Input Accuracy
Better than ±0 .5% of output span .
◆ Output (DC V/mA)
Current Output
Range: 0 to 20mA maximum (user-configured range) .
Compliance: 11V DC typical .
Load resistance range: 0 to 550 ohms .
Voltage Output
Ranges: 0 to 10V maximum (user-configured range) .
Compliance: 10mA max . with short circuit protection .
Output impedance: 1 ohms .
Accuracy (overall input to output)
Better than ±0 .1% of span for nominal output ranges
of 0 to 10V or 0 to 20mA .
Ambient Temperature Effect
Better than ±0 .018% of output span per °C or ±1μV,
whichever is greater .
Output Response Time (for input step change)
800mS typical to 98% of final output value .
◆ Environmental
Ambient Temperature
Operating: -25 to 70°C (-13 to 158°F) .
Storage: -40 to 85°C (-40 to 185°F) .
Relative Humidity
5 to 95%, noncondensing .
Power Requirements
611T: 10 to 36V DC . 24V DC @ 55mA .
612T: 10 to 36V DC . 24V DC @ 75mA .
Isolation
3-way (input/output/power) . 1500V AC for 60 seconds
or 250V AC continuous . Dual channel model includes
input-to-input isolation and outputs share a common .
Radiated Field Immunity (RFI)
Complies with EN61000-4-3 Level 3 and EN50082-1 .
Electromagnetic Field Immunity (EMI)
Less than ±0 .25% of output span effect .
Electrical Fast Transient (EFT)
Complies with EN61000-4-4 Level 3 and EN50082-1 .
Surge Withstanding Capability (SWC)
Complies with EN61000-4-5 Level 3 and EN50082-1 .
Electrostatic Discharge (ESD)
Complies with EN61000-4-2 Level 3 and EN50082-1 .
Radiated Emissions
Meets or exceeds EN50081-1 for Class B equipment .
Approvals
CE marked, UL, cUL listed (USA, Canada) .
UL3121 general product safety .
◆ Physical
Enclosure
Case: Self-extinguishing NYLON type 6 .6 polyamide
thermoplastic UL94 V-2 NEMA Type 1 enclosure .
Connectors (Removable Terminal Blocks)
Wire Range: AWG #12-24 .
Printed Circuit Boards
Military grade FR-4 epoxy glass circuit board .
Dimensions
1 .05W x 4 .68H x 4 .35D inches .
26 .7W x 118 .9H x 110 .5D millimeters .
Shipping Weight
1 pound (0 .45 Kg) packed .
Ordering Information
◆ Models
611T-0500
Single channel isolated transmitter
612T-0500
Dual channel isolated transmitter
Add “-C” suffix for optional factory configuration .
◆ Accessories (see Page 21)
5020-350
AC current sensor . See Page 20 for details .
PS5R-SD24
Power supply (24V DC, 2 .5A) .
TBK-B02
Optional terminal block kit, barrier strip style, 4 pcs .
TBK-S02
Optional terminal block kit, spring clamp style, 4 pcs .
DIN RAIL 3.0 or DIN RAIL 16.7
DIN rail strip, Type T, 3 in .(75mm) or 16 .7 in . (425mm)
20RM-16-DIN
19” rack-mount kit with DIN rail .
Holds sixteen 610T series transmitters .
AC Current Sensor
Optional terminal blocks: barrier strip (left) and
spring clamp (right). Cage clamp terminal is standard.
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 3 –
631T, 632T, 633T Multi-Channel 4-Wire Isolators
Description
Models
631T: Single I/O channel
632T: Dual I/O channel
633T: Single input, dual output (splitter)
These units receive 4-20mA process current
inputs and provide isolated 4-20mA output
signals . Each channel operates independently and
is isolated from the others to prevent
interaction between channels . Galvanic isola-
tion eliminates ground loops, reduces noise, and
blocks transient signals .
Units are shipped with factory calibration for
quick installation . These isolators also automati-
cally compensate for load resistance variations,
so re-calibration is rarely necessary . However,
adjustable zero and span trim pots are provided
to ensure precise calibration for maintenance
requirements and long term serviceability .
These isolators generate a 24V input excitation
supply suitable for powering one or two 2-wire
transmitters . The supply is current limited at each
output to prevent any excitation short from pull-
ing down the internal power supply . The internal
DC supply improves system performance by
isolating loops on a single or dual channel basis .
It saves space, complexity, and the expense of
installing additional supplies to power your field
loops .
Input / Output Ranges
4 to 20mA DC input
4 to 20mA DC output
Power Requirement
15-36V DC
90-250V AC (125V DC ±10%)
Four-wire isolated transmitter
Approvals
CE marked . UL, cUL listed .
Class I, Division 2, Groups A, B, C, D .
Key Features & Benefits
■ Two channels in a single unit saves space and
reduces costs .
■ Signal splitter model (633T) provides two iden-
tical isolated outputs from one input signal .
■ Built-in isolated excitation supply with short
circuit protection can drive up to two field
2-wire process loops .
■ Full isolation safely separates each input
channel, each output channel, the excitation
supply, and power .
■ Excellent accuracy and stability ensure reliable
operation in hostile environments .
■ Low input burden keeps voltage drop to less
than 1 .5V for full-scale current .
■ Supports wide 0 to 1000 ohm load range and
no trimming is required if the load varies .
■ Current limiting safely limits output to 27mA .
■ Pluggable terminals, zero/span trim pots and
power LEDs make installation, maintenance,
and long term service easy .
DC current input ◆ Single/dual-channel AC/DC-powered isolators ◆ Signal splitter
2-Wire
Xmitter
+
–
Field
Device
IN 1
IN 2
OUT 1
OUT 2
PWR
PLC / DCS
632T
IN +
IN –
EXC1
EXC2
IN+
IN–
+
–
+
–
+
–
+
–
R LOAD
R LOAD
Input
Input
+
–
+
–
4-20mA
Limiter
Limiter
24V+
RTN
24V+
RTN
4-20mA Source
4-20mA Sink
TB1
11
46
13
44
14
43
16
41
TB4
36 35 33 32
+24V OUT-
IN+ IN-
IN- IN+
OUT- +24V
TB4
TB3
C
L
ZERO
12
45
15
42 31 34
SPAN
PWR
PWR
3.75
(95.3)
TB1
RTN
EXC
OUT+
3.90
(99.1)
CHAN 1
OUT+ RTN
EXC
POWER
1.05
(26.7)
4.68
(118.9)
CHAN 2
TB3
2.34
(59.4)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
ZERO
SPAN
Acromag
CHAN 2
CHAN 1
4.35
(110.5)
NOTE: Dimensions Are INCHES (MILLIMETERS).
OUT-
IN-
IN+
+24V
OUT+
RTN
EXC CHAN 2 Input
POWER
GND
L2
L1
GND
DC-
DC+
+24V
OUT-
RTN
EXC CHAN 1
OUT+
631T/632T
633T
633T
632T
63xT-0500 (DC)
63xT-0100 (AC)
Labeling shown
for each model
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 4 –
Performance Specifications
Reference Test Conditions
Input/output current 4 to 20mA; Output load 250
ohms; Power 24V DC or 115V AC; 77°F (25°C) .
Input Range
4 to 20mA input (each channel) .
Input Burden
Voltage drop (631T, 632T):
Less than 1 .5V (75 ohms) at full scale .
Voltage drop (633T):
Less than 3 .0V (150 ohms) at full scale .
Input Overvoltage Protection
Bipolar Transient Voltage Suppressors (TVS) .
Input Excitation
24V DC ±10%, 22mA maximum each . Fully isolated .
Includes independent current limiting at EXC1 and
EXC2 near 23mA, each .
Output Range
4-20mA DC output (each channel) .
Output Trim Range
Zero and full-scale adjustment to ±4% .
Output Limiting
Outputs are limited to 27mA .
Output Load
0 to 1000 ohms (631T) .
0 to 950 ohms (632T, 633T) .
Output Load Resistance Effect
Less than ±0 .01% of output span effect for a ±100
ohm change in load resistance .
Output Response Time (for input step change)
25mS typical to 98% of final output value .
Accuracy
±0 .05% of output span . Error includes the combined
effects of isolator repeatability, hysteresis, terminal
point linearity and adjustment resolution .
Temperature Drift
Better than ±50ppm/°C (±0 .005%/°C) over the ambi-
ent temperature range . This specification includes the
combined effects of zero and span over temperature .
Calibration
Two 15-turn potentiometers (zero and span)
per output channel, accessible from front of the unit .
Bandwidth
-3dB at 50Hz, typical with a 500 ohm load .
Noise Rejection
Common mode: Better than 100dB at 60Hz, typical .
Normal mode: -6dB at 60Hz, typical, 500 ohm load .
LED Indicators
Green, one LED per output channel .
Constant ON indicates power applied .
◆ Environmental
Ambient Temperature
Operating: -25 to 75°C (-13 to 167°F),
[if excitation supplies are used on 632T or 633T
-25 to 60°C (-13 to 140°F)]
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity
5 to 95% .
Power Requirement
DC-powered units: 15-36V DC SELV .
AC-powered units: 90-250V AC (125V DC ±10%)
631T: 1 .5 watts without excitation, 2 .4 watts with
excitation .
632T, 633T: 3 .0 watts without excitation, 4 .8 watts
with excitation .
Isolation
Inputs, outputs, individual channels, power, and
excitation supplies are isolated from each other for
common-mode voltages up to 250V AC, or 354V
DC off ground, on a continuous basis (will withstand
1500V AC dielectric strength test for one minute
without breakdown) .
Electromagnetic Field Immunity (EMI)
Less than ±0 .25% of output span effect under the
influence of electromagnetic fields from switching
solenoids, commutator motors, and drill motors .
Meets Immunity Standards Per EN50082-1
Electrostatic Discharge (ESD) Immunity
4KV direct contact and 8KV air-discharge to the
enclosure port per EN61000-4-2 .
Radiated Field Immunity (RFI)
10V/M, 80 to 1000MHz AM and 900MHz keyed
carrier, per EN61000-4-3 and ENV50204 .
Electrical Fast Transient Immunity (EFT)
2KV to power and 1KV to signal I/O per EN61000-4-4 .
Conducted RF Immunity (CRFI)
10Vrms, 150KHz to 80MHz, per EN61000-4-6 .
Surge Immunity
0 .5KV per EN61000-4-5 .
Emissions Per European Norm EN50081-1
Radiated Frequency Emissions
30 to 1000MHz per EN55022 Class B .
Approvals
CE marked, UL & cUL listed .
Hazardous Locations: Class I: Div . 2; Groups A, B, C, D
◆ Physical
Enclosure
Case: Self-extinguishing NYLON type 6 .6 polyamide
thermoplastic UL94 V-2 NEMA Type 1 enclosure .
Connectors (Removable Terminal Blocks)
Wire Range: AWG #14-22 (AWG #12 stranded only) .
Printed Circuit Boards
Military grade FR-4 epoxy glass circuit board .
Dimensions
1 .05W x 4 .68H x 4 .35D inches .
26 .7W x 95 .3H x 110 .5D millimeters .
Ordering Information
◆ Models
631T-0100
Single channel isolator, AC-powered
631T-0500
Single channel isolator, DC-powered
632T-0100
Dual channel isolator, AC-powered
632T-0500
Dual channel isolator, DC-powered
633T-0100
Single input with dual isolated output, AC-powered
633T-0500
Single input with dual isolated output, DC-powered
◆ Accessories (see Page 21)
PS5R-SD24
Power supply (24V DC, 2 .5A) .
TBK-B02
Optional terminal block kit, barrier strip style, 4 pcs .
TBK-S02
Optional terminal block kit, spring clamp style, 4 pcs .
DIN RAIL 3.0
DIN RAIL 16.7
DIN rail strip, Type T, 3 inches (75mm) or
16 .7 inches (425mm)
20RM-16-DIN
19” rack-mount kit with DIN rail .
Holds sixteen 630T transmitters .
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 5 –
651T, 652T, 653T Multi-Channel, Two-Wire Isolators
Description
Models
651T: Single I/O channel
652T: Dual I/O channel
653T: Single input, dual output (splitter)
These units receive 4-20mA process current
inputs and provide isolated 4-20mA output
signals . Each channel operates independently
and is isolated from the others to prevent inter-
action between channels .
For easy troubleshooting, each unit has LEDs and
diagnostic test points . Power LEDs help identify
output open loop conditions . The precision
10 ohm sense resistor enables monitoring of the
output signal without disturbing field wiring .
Input / Output Ranges
4 to 20mA DC input
4 to 20mA DC output
Power Requirement
12 to 36V DC (loop-powered)
Two-wire transmitter
Approvals
CE marked . UL, cUL listed
Class I, Division 2, Groups A, B, C, D .
Key Features & Benefits
■ Two channels in a single unit
saves space and reduces costs .
■ Signal splitter model (653T) provides two
identical outputs from one input signal .
■ Galvanic isolation eliminates ground loops,
reduces noise, and blocks transient signals .
■ Independent channels prevent signal interac-
tion and offer spares for later use .
■ Power LEDs provide a visual indication
of operational process loops .
■ Excellent accuracy and stability ensure reliable
DC current input ◆ Single/dual-channel DC-powered isolators ◆ Signal splitter
Acromag
DIN EN 50022, 35mm
"T" RAIL DIN MOUNTING
(59.4)
2.34
C
L
(95.3)
3.75
ZERO
SPAN
R
1.05
(26.7)
NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS)
(107.1)
4.215
(99.1)
3.90
4.35
(110.5)
CHAN 1
PWR
CH1 IN CH1 OUT
IN-
IN+
OUT-
SNS
OUT+
11 12 13 14 15 16
TB1
CH2 IN CH2 OUT
IN-
IN+
OUT-
SNS
OUT+
21 22 23 24 25 26
TB2
TB1
ZERO
SPAN
CHAN 2
PWR
INPUT CH1 OUT
IN-
IN+
OUT-
SNS
OUT+
11 12 13 14 15 16
TB1
CH2 OUT
OUT-
SNS
OUT+
21 22 23 24 25 26
TB2
Model 652T-0600
Model 651T-0600
Model 652T-0600
Model 653T-0600
TB1 TB2
Model 653T-0600
INPUT
OUT
PLC / DCS
IN
+
– –
+
R L
4-20mA
24V DC
4-20mA
4-20mA Source
651T
+
–
Field
Device
–
+
Single channel shown. Dual channel units are available.
Note: 670T series transmitters are for output resistive loads only (sources current).
For more information on the 670T Transmitter, refer to Page 14. Application notes are on Page 16.
Note: 650T series transmitters are for two-wire transmitter interfaces (sinks current).
For application notes using 650T Transmitters, refer to Page 16.
650T Series Isolation Diagram
OUT OUT
PLC / DCS
IN
–
+
R L
4-20mA
+
–
+
–
671T
Single channel shown. Quad channel units are available.
4-20mA
Field
Device
670T Series Isolation Diagram
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 6 –
Performance Specifications
Reference Test Conditions
Input/Output current: 4 to 20mA; output load 500
ohms; 77°F (25°C) .
Input range
4 to 20mA input (each channel) .
Input burden
Voltage drop (651T, 652T): Less than 1 .5V, typical
(75 ohm equivalent) .
Voltage drop (653T): Less than 3 .0V, typical
(150 ohm equivalent) .
Output range
4-20mA DC output (each channel) .
Rl = (Psupply-12V) / 0 .02
Output compliance
Psupply = 12V + (0 .02 x Rload)
Output limiting
Outputs are limited to 36mA .
Output ripple
Less than ±0 .1% of the maximum output span .
Accuracy
±0 .1% of output span . Error includes the combined
effects of isolator repeatability, hysteresis, terminal
point linearity and adjustment resolution .
Ambient temperature effect
Less than ±0 .006% of input span per °F (±0 .01% per
°C) over the ambient temperature range for reference
test conditions . This specification includes the com-
bined effects of zero and span over temperature .
Calibration
Two 15-turn potentiometers (zero and span)
per channel, accessible from front of the unit .
Bandwidth
-3dB at 45Hz, typical .
Response time
For a step input, the output reaches 98% of output
span in 15mS, typical .
Noise rejection
Common mode: 100dB at 60Hz, typical .
Normal mode: -5dB at 60Hz, 100 ohm source, typical .
Diagnostics
LED power indicator: Off for output open loop detec-
tion, power, or load compliance problem .
Field test points: An internal 10 ohm sense resistor
provides test points for monitoring the output signal
current during field maintenance .
◆ Environmental
Ambient Temperature
Operating: -25 to 70°C (-13 to 158F) .
Storage: -40 to 85°C (-40 to 185°F) .
Relative Humidity
5 to 95% .
Power Requirement
12 to 50V DC for each output channel .
Isolation
Inputs, outputs, and individual channels are
isolated from each other for common-mode
voltages up to 250V AC, or 354V DC off ground, on
a continuous basis (will withstand 1500V AC dielectric
strength test for one minute without breakdown) .
Radiated Field Immunity (RFI)
Complies with EN61000-4-3 Level 3 (10V/m,
30 to 1000MHz) and European Norm EN50082-1 .
Electromagnetic Field Immunity (EMI)
Less than ±0 .25% of output span effect under the
influence of electromagnetic fields from switching
solenoids, commutator motors, and drill motors .
Surge Immunity
Complies with EN61000-4-5 Level 3 (2KV) and
European Norm EN50082-1 .
Electrical Fast Transient (EFT)
Complies with EN61000-4-4 Level 3 (2KV) and
European Norm EN50082-1 .
Electrostatic Discharge (ESD)
Complies with EN61000-4-2 Level 3 (8KV air, 4KV
direct to the enclosure port) and European Norm
EN50082-1 .
Radiated Emissions
Meets or exceeds European Norm EN50081-1 for Class
B equipment .
Approvals
CE marked, UL & cUL listed .
Hazardous Locations: Class I: Div . 2; Groups A, B, C, D
◆ Physical
Enclosure
Case: Self-extinguishing NYLON type 6 .6 polyamide
thermoplastic UL94 V-2 NEMA Type 1 enclosure .
Connectors (Removable Terminal Blocks)
Wire Range: AWG #14-22 (AWG #12 stranded only) .
Printed Circuit Boards
Military grade FR-4 epoxy glass circuit board .
Dimensions
1 .05W x 4 .68H x 4 .35D inches .
26 .7W x 95 .3H x 110 .5D millimeters .
Shipping Weight
1 pound (0 .45 Kg) packed .
Ordering Information
◆ Models
651T-0600
Single channel 2-wire transmitter
652T-0600
Dual channel 2-wire transmitter
653T-0600
Single input with dual isolated output transmitter
◆ Accessories (see Page 21)
PS5R-SD24
Power supply (24V DC, 2 .5A) .
TBK-B01
Optional terminal block kit, barrier strip style, 2 pcs .
TBK-S01
Optional terminal block kit, spring clamp style, 2 pcs .
DIN RAIL 3.0
DIN RAIL 16.7
DIN rail strip, Type T, 3 inches (75mm) or
16 .7 inches (425mm)
20RM-16-DIN
19” rack-mount kit with DIN rail .
Holds sixteen 650T transmitters .
Optional terminal blocks: barrier strip (left) and
spring clamp (right). Cage clamp terminal is standard.
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 7 –
Description
Models
654T: Dual DC voltage input channels
These units accept DC voltage input signals,
provide isolation, and output proportional DC
current signals . With two independent I/O
channels in a slim package, the 654T is ideal for
panel shops and end-users who require a high-
density signal conditioner that can cover a broad
range of measurement applications .
Configuration is fast and easy . First, you select
the input range for each channel with simple
DIP switches . Then, you set your zero/full-scale
output values using the noninteractive increase/
decrease toggle switches on the front panel to
modify the output signal until the desired output
value is read on your voltmeter . The switches
make it easy to calibrate a normal (proportional)
or reverse-acting (inverse) response in seconds .
After setting the desired calibration, you can
engage the safety lockout feature on the DIP
switch to prevent accidental changes and
unauthorized tampering .
The 654T provides two independent high-voltage
input isolation circuits . Loss of power or a failure
on one channel has no effect on the other . The
second channel can be used as a built-in spare
for reduced downtime should the first channel
fail . The spare channel becomes operational by
simply moving the wired terminal block over to
the vacant channel .
Input Ranges
Bipolar: ±78mV to ±625mV (selectable ranges)
Unipolar: 0–1 .25 to 0–10V DC (selectable ranges)
Output Range
4 to 20mA DC
Power Requirement
12 to 50V DC (loop-powered)
Two-wire transmitter
Approvals
CE marked . UL, cUL listed
Class I; Division 2; Groups A, B, C, D .
Key Features & Benefits
■ DIP switch-configuration simplifies installation
without analog pots, jumpers, or software .
■ Isolation eliminates ground loops, reduces
noise, and blocks transient signals .
■ One-step calibration with increase/decrease
toggle switches simplifies field adjustments for
faster and easier maintenance .
■ Automatic self-calibration compensates for
temperature effects and component aging to
deliver maintenance-free operation .
■ Configuration lockout safety feature helps
prevent tampering and accidental calibration
changes .
■ Reverse-acting output capability enables
inverse proportional control signals .
■ Dual channel model saves space and reduces
equipment costs .
■ High-resolution 16-bit S-D A/D converters
deliver superior accuracy for more reliable
measurements .
■ Built-in transient voltage suppressors protect
circuitry from electrical interference .
DC voltage input ◆ Dual-channel DC-powered transmitters
654T Multi-Channel, Two-Wire Transmitters
IN 1 OUT 1
OUT 2
PLC / DCS
+
–
IN 2
+
–
+
–
+
–
R S
4-20mA
24V DC
R S
4-20mA
24V DC
Indicator
654T
+
–
Ch-to-Ch
Isolation
DIN EN 50022, 35mm
"T" RAIL DIN MOUNTING
(59.4)
2.34
C
L
(95.3)
3.75
1.05
(26.7)
NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS)
(116.8)
4.60
R
CHAN 2
FS
UP DN
Z
CHAN 1
FS
UP DN
Z
(99.1)
3.90
4.35
(110.5)
36
CHANNEL 2
TB3
33
21 22
35 34 32 31
OUT-
OUT+
IN-
IN+
CHANNEL 1
OUT+
OUT-
IN+
IN-
23 24 25 26
CH1 Dip Switches
CH2 Dip Switches
TB2
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 8 –
Performance Specifications
◆ General Input
Analog to Digital Converter (ADC)
16-bit S-D A/D converter .
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz with
100 ohm input unbalance .
Common Mode: Better than 140dB @ 60Hz with
100 ohm input unbalance .
Input Overvoltage Protection
Bipolar Transient Voltage Suppressors (TVS) .
◆ DC Voltage Input
Input Range
DIP switch-selectable . See table below .
Input Recommended
Range Minimum Span (10%)
A) ±78mV 15mV
B) ±156mV 31mV
C) ±313mV 62mV
D) ±625mV 124mV
E) 0 to 1 .25V 125mV
F) 0 to 2 .5V 250mV
G) 0 to 5V 500mV
H) 0 to 10V 1000mV
Span adjust: See table above .
Zero adjust: * full range .
Input Impedance
110K ohms, typical
◆ Output
Output Range
Range: 4 to 20mA DC, 3 .8 to 24mA range typical .
Output Compliance
R load = (V supply - 12V) / 0 .02A
600 ohms at 24V DC supply
Output Response Control
Proportional/inverse selectable .
Ambient Temperature Effect
Better than ±0 .018% of input span per °C
(±0 .01% per °F) .
Output Resolution
Output resolves to 1 part in 6546 for the nominal
4 to 20mA output span .
Output Response Time (for input step change)
980mS typical to 98% of final output value .
Accuracy (overall input to output)
±0 .1% of output span .
◆ Environmental
Ambient Temperature
Operating: -25 to 75°C (-13 to 167°F) .
Storage: -40 to 85°C (-40 to 185°F) .
Relative Humidity
5 to 95%, noncondensing .
Power Requirement
12 to 50V DC @ 25mA for each output channel .
Isolation
Inputs, outputs, and individual channels are
isolated from each other for common-mode
voltages up to 250V AC, or 354V DC off ground, on
a continuous basis (will withstand 1500V AC dielectric
strength test for one minute without breakdown) .
Radiated Field Immunity (RFI)
Designed to comply with EN61000-4-3 Level 3 and
EN50082-1 .
Electromagnetic Field Immunity (EMI)
Less than ±0 .25% of output span effect .
Electrical Fast Transient (EFT)
Complies with EN61000-4-4 Level 3 (2KV) and
EN50082-1 .
Electrostatic Discharge (ESD)
Complies with EN61000-4-2 Level 3 (8KV air or 4KV
direct) and EN50082-1 .
Radiated Emissions
Meets or exceeds EN50081-1 for Class B equipment .
Approvals
CE marked, UL & cUL listed .
Hazardous Locations: Class I: Div . 2; Groups A, B, C, D
◆ Physical
Enclosure
Case: Self-extinguishing NYLON type 6 .6 polyamide
thermoplastic UL94 V-2 NEMA Type 1 enclosure .
Connectors (Removable Terminal Blocks)
Wire Range: AWG #12-24 .
Printed Circuit Boards
Military grade FR-4 epoxy glass circuit board .
Dimensions
1 .05W x 4 .68H x 4 .35D inches .
26 .7W x 118 .9H x 110 .5D millimeters .
Shipping Weight
1 pound (0 .45 Kg) packed .
Ordering Information
◆ Models
654T-0600
Dual channel DC voltage 2-wire transmitter .
Add “-C” suffix for optional factory configuration .
◆ Accessories (see Page 21)
PS5R-SD24
Power supply (24V DC, 2 .5A) .
TBK-B01
Optional terminal block kit, barrier strip style, 2 pcs .
TBK-S01
Optional terminal block kit, spring clamp style, 2 pcs .
DIN RAIL 3.0
DIN RAIL 16.7
DIN rail strip, Type T, 3 inches (75mm) or
16 .7 inches (425mm)
20RM-16-DIN
19” rack-mount kit with DIN rail .
Holds sixteen 650T transmitters .
IN+
IN-
OUT+
OUT-
DC
Voltage
4-20mA
R Load
Voltage
Source
+
-
Optional terminal blocks: barrier strip (left) and
spring clamp (right) . Cage clamp terminal is standard .
Input Connections
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 9 –
655T, 656T Multi-Channel, Two-Wire Transmitters
Description
Models
655T: Single TC/mV input channel
656T: Dual TC/mV input channel
These units accept universal thermocouple and
millivolt input signals, provide isolation, and out-
put proportional DC current signals . The output
can also be linearized to the input sensor signal .
Single-channel 655T and dual-channel 656T units
are ideal for panel shops and end-users who
require a high-density signal conditioner that can
cover a broad range of temperature measure-
ment applications .
Configuration is fast and easy . First, you select
the input type with a simple DIP switch . Then,
you set your zero/full-scale output values using
a toggle switch on the front panel to increase
or decrease the signal until you read the desired
output value on your voltmeter . The toggles
make it easy to calibrate a normal (proportional)
or reverse-acting (inverse) response in seconds .
After setting the desired calibration, just press
the mode/set toggle and your configuration set-
tings are safely saved to nonvolatile memory .
Both models provide high-voltage input isolation
(output and power circuits share a common) . On
dual channel units, each channel operates inde-
pendently, with inputs isolated from each other,
to prevent interaction between channels .
Input Ranges
TC types: J, K, T, R, S, E, B, N
(DIP switch selection)
DC voltage: ±15 .6mV to ±62 .5mV, 0 to 1V DC
Output Ranges
4 to 20mA DC
Power Requirement
12 to 50V DC (loop-powered)
Two-wire transmitter
Approvals
CE marked . UL, cUL listed
Class I; Division 2; Groups A, B, C, D .
Key Features & Benefits
■ Selectable thermocouple input types offer
flexibility to fit many applications .
■ DIP switch-configuration and self-ranging
technologies speed installation without pots,
jumpers, or software .
■ Linearizer function provides an output that is
linear to the temperature or millivolt signal .
■ Isolation eliminates ground loops, reduces
noise, and blocks transient signals .
■ Toggle-switch calibration simplifies field
adjustments for faster and easier maintenance .
■ Configuration lockout safety feature prevents
tampering and accidental changes .
■ Reverse-acting output capability enables
inverse proportional control signals .
■ Dual channel model saves space and reduces
equipment costs .
■ CJC control only requires a millivolt source to
calibrate modules
■ High-resolution S-D A/D converters deliver
superior accuracy for reliable measurements .
Thermocouple and millivolt input ◆ Single/dual channel loop-powered transmitter
IN 1 OUT 1
OUT 2
PLC / DCS
+
–
IN 2
+
–
+
–
+
–
R S
4-20mA
24V DC
R S
4-20mA
24V DC
Indicator
656T
+
–
Ch-to-Ch
Isolation
In = Out
Isolation
(99.1)
3.90
4.35
(110.5)
36
OUT
656T-0600
656T-0600
655T-0600
TB3
33
IN CJC
21 22
35 34 32 31
OUT-
OUT+
IN-
IN+
CJC IN OUT
OUT+
OUT-
IN+
IN-
23 24 25 26
CH1 Dip Switches
CH2 Dip Switches
TB2
DIN EN 50022, 35mm
"T" RAIL DIN MOUNTING
(59.4)
2.34
C
L
(95.3)
3.75
1.05
(26.7)
NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS)
(118.9)
4.68
Acromag
R
CHAN 2
CHAN 1
FS
Z
DN UP
FS
Z
DN UP
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 10 –
Performance Specifications
◆ General Input
Analog to Digital Converter (ADC)
16-bit S-D A/D converter .
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz .
Common Mode: Better than 100dB @ 60Hz .
Input Overvoltage Protection
Bipolar Transient Voltage Suppressors (TVS) .
◆ Thermocouple Input
Input Ranges (switch-selectable)
TC Type Temperature Range Accuracy
J -210 to 760°C (-346 to 1400°F) ±0 .5°C
K 200 to 1372°C (-328 to 2502°F) ±0 .5°C
T -260 to 400°C (-436 to 752°F) ±0 .5°C
R -50 to 1768°C (-58 to 3214°F) ±1 .0°C
S -50 to 1768°C (-58 to 3214°F) ±1 .0°C
E -200 to 1000°C (-328 to 1832°F) ±0 .5°C
B 260 to 1820°C (500 to 3308°F) ±1 .0°C
N -230 to 1300°C (-382 to 2372°F) ±0 .5°C
Span adjust: Full range . 100°C or 3mV minimum span
recommended .
Zero adjust: 0 to 90 % of full range .
Thermocouple Linearization
On/off selectable .
Thermocouple Break Detection
TC sensor failure can be configured for either upscale
or downscale .
Cold Junction Compensation (CJC) Control
On/off selectable .
◆ Millivolt Input
Input Range
Ranges: ±15 .6, ±31 .3, ±62 .5mV
0 to 0 .125, 0 .25, 0 .5, 1 .0V DC
Span adjust: 10 to * of range .
Zero adjust: 0 to 90% of range .
◆ Output
Output Range
Range: 4 to 20mA DC, 3 .8 to 22mA range typical .
Output Compliance
Rload = (Vsupply - 12V) / 0 .02A
Output Response Control
Proportional/inverse selectable .
Ambient Temperature Effect
Better than ±0 .006% of input span per °C or
±100ppm/°C, whichever is greater .
Output Response Time (for input step change)
700mS typical to 98% of final output value .
◆ Environmental
Ambient Temperature
Operating: -25 to 75°C (-13 to 167°F) .
Storage: -40 to 85°C (-40 to 185°F) .
Relative Humidity
5 to 95%, noncondensing .
Power Requirement
12 to 50V DC @ 25mA for each output channel .
Isolation
Inputs, outputs, and individual channels are
isolated from each other for common-mode
voltages up to 250V AC, or 354V DC off ground, on
a continuous basis (will withstand 1500V AC dielectric
strength test for one minute without breakdown) .
Radiated Field Immunity (RFI)
Complies with EN61000-4-3 Level 3 and EN50082-1 .
Electromagnetic Field Immunity (EMI)
Less than ±0 .25% of output span effect .
Electrical Fast Transient (EFT)
Complies with EN61000-4-4 Level 3 and EN50082-1 .
Electrostatic Discharge (ESD)
Complies with EN61000-4-2 Level 3 and EN50082-1 .
Radiated Emissions
Meets or exceeds EN50081-1 for Class B equipment .
Approvals
CE marked, UL & cUL listed .
Hazardous Locations: Class I: Div . 2; Groups A, B, C, D .
◆ Physical
Enclosure
Case: Self-extinguishing NYLON type 6 .6 polyamide
thermoplastic UL94 V-2 NEMA Type 1 enclosure .
Connectors (Removable Terminal Blocks)
Wire Range: AWG #12-24 .
Printed Circuit Boards
Military grade FR-4 epoxy glass circuit board .
Dimensions
1 .05W x 4 .68H x 4 .35D inches .
26 .7W x 118 .9H x 110 .5D millimeters .
Shipping Weight
1 pound (0 .45 Kg) packed .
Ordering Information
◆ Models
655T-0600
Single channel TC 2-wire transmitter . Full feature set .
656T-0600
Dual channel TC 2-wire transmitter . Full feature set .
Add “-C” suffix for optional factory configuration .
656T-E600
Dual channel TC 2-wire transmitter . Economy version .
TC Type J, K and 0-125mV input ranges only .
No linearization . No inverse output (proportional only) .
Accessories (see Page 21)
PS5R-SD24
Power supply (24V DC, 2 .5A) .
DIN RAIL 3.0
DIN RAIL 16.7
DIN rail strip, Type T,
3 inches (75mm) or 16 .7 inches (425mm)
20RM-16-DIN
19” rack-mount kit with DIN rail .
Holds sixteen 650T series transmitters .
IN+
IN-
OUT+
OUT-
TC
Input
Sensor
CJC
4-20mA
R Load
+ -
IN+
IN-
OUT+
OUT-
Millivolt
Sensor
CJC
4-20mA
R Load
Voltage
Source
+
-
+ -
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 11 –
Description
Models
657T: Single RTD input channel
658T: Dual RTD input channels
These units accept universal RTD or resistance
input signals and output proportional DC current
signals . The output can also be linearized to the
input sensor signal . Single-channel 657T and
dual-channel 658T units are ideal for panel shops
and end-users who require a high-density sig-
nal conditioner that can accommodate a broad
range of temperature measurement applications .
Configuration is fast and easy . First, you select
the input type with a simple DIP switch . Then,
you set your zero/full-scale output values using
a toggle switch on the front panel to increase
or decrease the signal until you read the desired
output value on your voltmeter . The toggles
make it easy to calibrate a normal (proportional)
or reverse-acting (inverse) response in seconds .
After completing the calibration, just press the
mode/set toggle and your configuration settings
are safely saved to nonvolatile memory .
Input Ranges
RTD: 100 ohm Pt, 120 ohm Ni, 10 ohm Cu
Resistance: 0 to 500 ohms
Output Range
4 to 20mA DC
Power Requirement
12 to 50V DC (loop-powered)
Two-wire transmitter
Approvals
CE marked . UL, cUL listed
Class I; Division 2; Groups A, B, C, D .
Key Features & Benefits
■ Selectable RTD input types offer flexibility
to fit many applications .
■ DIP switch-configuration and self-ranging
technologies speed installation without pots,
jumpers, or software .
■ Toggle-switch calibration simplifies field
adjustments for faster and easier maintenance .
■ Configuration lockout safety feature prevents
tampering and accidental changes .
■ Reverse-acting output capability enables
inverse proportional control signals .
■ Dual channel model saves space and reduces
equipment costs .
■ High-resolution S-D A/D converters deliver
superior accuracy for reliable measurements .
■ Lead break detection supports upscale or
downscale failsafe mode .
RTD / resistance input ◆ Single/dual channel loop-powered transmitter
657T, 658T Multi-Channel, Two-Wire Transmitters
IN 1 OUT 1
OUT 2
PLC / DCS
+
–
IN 2
+
–
+
–
+
–
R S
4-20mA
24V DC
R S
4-20mA
24V DC
Indicator
658T
+
–
(99.1)
3.90
4.35
(110.5)
36
OUT
658T-0600
658T-0600
657T-0600
TB3
33
INPUT
21 22
35 34 32 31
OUT-
OUT+
RTN
IN+
EXC+
IN-
INPUT OUT
OUT+
OUT-
IN-
IN+
EXC+
RTN
23 24 25 26
CH1 Dip Switches
CH2 Dip Switches
TB2
DIN EN 50022, 35mm
"T" RAIL DIN MOUNTING
(59.4)
2.34
C
L
(95.3)
3.75
1.05
(26.7)
NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS)
(118.9)
4.68
Acromag
R
CHAN 2
CHAN 1
FS
Z
DN UP
FS
Z
DN UP
Optional terminal blocks: barrier strip (left) and
spring clamp (right). Cage clamp terminal is standard.
Isolated Transmitters: 600T Series
248-295-0880 ■ ■ ■ ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
– 12 –
Performance Specifications
◆ General Input
Analog to Digital Converter (ADC)
16-bit S-D A/D converter .
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz .
Common Mode: Better than 100dB @ 60Hz .
Input Overvoltage Protection
Bipolar Transient Voltage Suppressors (TVS) .
Input Impedance
400K ohm at 10mV span;
input current, ±25nA, typical (±30nA, max .) .
◆ RTD Input
RTD Input Ranges
100W Pt, 120W Ni, or 10W Cu; user-configured .
RTD °C Range (°F Range) Accuracy
Pt1 -200 to 850°C (-328 to 1562°F) ±0 .25°C
Pt2 -200 to 850°C (-328 to 1562°F) ±0 .25°C
Ni -80 to 320°C (-112 to 608°F) ±0 .25°C
Cu - 200 to 260°C (-328 to 500°F) ±1 .00°C
Alpha: Pt1 (a = 1 .3850), Pt2 (a = 1 .3911),
Ni a = 1 .6720), Cu (a = 1 .4272) .
2, 3, or 4-wire configurations supported . Module
provides sensor excitation, linearization, lead-wire com-
pensation, and sensor break detection .
RTD Excitation Current
0 .5mA DC typical, all types .
RTD Lead-Wire Compensation
25 ohms per lead .
RTD Break Detection
Configurable for either upscale or downscale .
◆ Resistance Input
Resistance Input Range
0 to 500 ohms .
Resistance Accuracy
±0 .05 ohms .
◆ Output
Output Range
Range: 4 to 20mA DC, 3 .8 to 22mA range typical .
Output Compliance
Rload = (Vsupply - 12V) / 0 .02A
Output Response Control
Resistance Input Range
0 to 500 ohms .
Resistance Accuracy
±0 .05 ohms .
◆ Output
Output Range
Range: 4 to 20mA DC, 3 .8 to 22mA range typical .
Output Compliance
Rload = (Vsupply - 12V) / 0 .02A
Output Response Control