![]() | 6XV1830-0EH10 SIMATIC NET, PROFIBUS 快速標(biāo)準(zhǔn)電纜 GP, 2 芯, 屏蔽, 為快速安裝而特殊設(shè)計(jì),zui大長度: 1000m, zui小訂購數(shù)量: 20m, 按米銷售 |
![]() | 6XV1830-3EH10 SIMATIC NET, PROFIBUS FC 拖纜, PROFIBUS 拖纜, zui大加速度:4 m/s2, 至少 3 百萬次 彎曲次數(shù),彎曲半徑: 約 120mm,雙芯屏蔽線,按米銷售,zui大長度: 1000m, zui小訂購量: 20 m |
FastConnect 電纜 附件如下 |
![]() | 6ES7972-0BA52-0xA0 DP 接頭, 90 度出線, 不帶 PG 接口, 快連式 |
| |||||
![]() | 6ES7972-0BB52-0xA0 DP 接頭, 90 度出線, 帶有 PG 接口 , 快連式 |
| |||||
![]() | 6GK1500-0FC10 PB FC RS 485 PLUG 180, PB-PLUG WITH FASTConNECT ConNECTOR AND AXIAL CABLE- OUTLET F. INDUSTRY PC, SIMATIC OP, OLM, TRANSMISSION RATE: 12 MBIT/S, TERMINATING RESISTOR WITH SERAR. FUNCTION, PLASTIC HOUSING |
| |||||
![]() | 6GK1905-6AA00 SIMATIC NET, PROFIBUS FastConnect 剝線工具, 用于 PROFIBUS FastConnect 總線電纜的快速剝線 |
| |||||
![]() | 6GK1905-6AB00 SIMATIC NET, PROFIBUS FastConnect 刀片盒, 剝線工具備用刀片盒,共 5片 數(shù)量單元: 5 |
| |||||
![]() | 6GK1975-1AA00-3AA0 SIMATIC NET 使用手冊匯編, 介紹通訊系統(tǒng)、協(xié)議、產(chǎn)品,... 2007版, DVD,德文/英文 |
- 用于不同應(yīng)用區(qū)域的不同類型(例如,地下電纜、拖曳電纜、危險(xiǎn)區(qū)域(Zone 1 和 Zone 2))
- 雙層屏蔽,抗干擾性能好
- 阻燃總線連接電纜(不含鹵素)。
- 由于電纜上印有以米表示的長度標(biāo)記,因此易于確定長度
- UL 認(rèn)證
Benefits
- 由于特殊的總線電纜,有很廣的應(yīng)用范圍。
- 由于使用了雙層屏蔽電纜和集成式接地技術(shù),網(wǎng)絡(luò)具有抗干擾功能。
- 采用 FastConnect (快速連接) 電纜,連接器連接簡單又快速,從而節(jié)省了時(shí)間。
- 產(chǎn)品中不含硅硐,因此特別適用于汽車工業(yè) (如上釉流水線)。
Area of application
為了構(gòu)建 PROFIBUS DP 網(wǎng)絡(luò),提供有不同類型的電纜,可滿足不同類型應(yīng)用的要求。一般地,應(yīng)該使用所列出的電纜。有關(guān)網(wǎng)絡(luò)組態(tài)的詳細(xì)信息,請(qǐng)參見 PROFIBUS 網(wǎng)絡(luò)手冊。
UL 認(rèn)證
用于網(wǎng)絡(luò)電纜的 UL 列表(安全標(biāo)準(zhǔn))對(duì)于美國和加拿大市場尤為必需。根據(jù)電纜敷設(shè)在建筑物中位置來決定適當(dāng)?shù)恼J(rèn)證要求。這適用所有電纜,這些電纜從一個(gè)機(jī)器敷設(shè)到一遠(yuǎn)程控制柜,位于電纜架上并保護(hù)著建筑物。通過 UL 認(rèn)證的電纜在其名稱后面附加字母“GP”(通用)。
Ex認(rèn)證
用于本質(zhì)安全 PROFIBUS DP 應(yīng)用的電纜在其名稱后面附加字母“IS”(本質(zhì)安全)
Technical Specifications
Order number | 6XV1830-0EH10 | 6XV1831-2A | 6XV1830-0JH10 | 6XV1830-0GH10 | |
---|---|---|---|---|---|
Product type designation | PROFIBUS FC Standard Cable GP | PROFIBUS FC Standard Cable IS GP | PROFIBUS FC Robust Cable | PROFIBUS FC Food Cable | |
Product description | Standard bus cable (2-core), sold by the meter, unassembled | Standard bus cable for fast installation, sold by the meter, unassembled | Special bus cable (2-core), sold by the meter, unassembled | Bus cable (2-core), sold by the meter, unassembled | |
Suitability for use | Standard cable specially designed for fast, permanent installation | Used for intrinsically safe distributed I/O systems for permanent installation | For use in chemically and mechanically demanding environments | For use in the food, beverages and tobacco industries | |
Cable designation | 02YSY (ST) CY 1x2x0,64/2,55-150 VI KF 40 FR | 02YSY (ST) CY 1x2x0,64/2,55 BL KF40 FR | 02YSY (ST) C11Y 1x2x0,64/2,55-150 VI KF 40 FR | 02YSY (ST) C2Y 1x2x0,64/2,55-150 KF 40 | |
Electrical data | |||||
Damping ratio per length | |||||
| 2.5 dB/km | 2.5 dB/km | 2.5 dB/km | 2.5 dB/km | |
| 4 dB/km | 4 dB/km | 4 dB/km | 4 dB/km | |
| 22 dB/km | 22 dB/km | 22 dB/km | 22 dB/km | |
| 42 dB/km | 42 dB/km | 42 dB/km | 42 dB/km | |
Impedance | |||||
| 150 Ω | 150 Ω | 150 Ω | 150 Ω | |
| 270 Ω | 270 Ω | 270 Ω | 270 Ω | |
| 185 Ω | 185 Ω | 185 Ω | 185 Ω | |
| 150 Ω | 150 Ω | 150 Ω | 150 Ω | |
Relative symmetrical tolerance | |||||
| 10 % | 10 % | 10 % | 10 % | |
| 10 % | 10 % | 10 % | 10 % | |
| 10 % | 10 % | 10 % | 10 % | |
Loop resistance per length maximum | 110 mΩ/m | 110 mΩ/m | 110 mΩ/m | 110 mΩ/m | |
Shield resistance per length maximum | 9.5 Ω/km | 9.5 Ω/km | 9.5 Ω/km | 9.5 Ω/km | |
Insulation resistance coefficient | 16 000 GΩ·m | ||||
Capacity per length at 1 kHz | 28.5 pF/m | 28.5 pF/m | 28.5 pF/m | 28.5 pF/m | |
Operating voltage | |||||
| 100 V | 100 V | 100 V | 100 V | |
Mechanical data | |||||
Number of electrical cores | 2 | 2 | 2 | 2 | |
Design of the shield | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | |
Type of electrical connection FastConnect | Yes | Yes | Yes | Yes | |
Core diameter | |||||
| 0.64 mm | ||||
Outer diameter | |||||
| 0.65 mm | 0.64 mm | 0.65 mm | 0.65 mm | |
| 2.55 mm | 2.55 mm | 2.55 mm | 2.55 mm | |
| 5.4 mm | 5.4 mm | 5.4 mm | 5.4 mm | |
| 8 mm | 8 mm | 8 mm | 8 mm | |
Symmetrical tolerance of the outer diameter of cable sheath | 0.4 mm | 0.4 mm | 0.4 mm | 0.4 mm | |
Material | |||||
| PE | PE | PE | PE | |
| PVC | PVC | PVC | PVC | |
| PVC | PVC | PUR (TPE-U) | PE; Outer cover made of PE is especially suitable for the food processing industry | |
Color | |||||
| red/green | red/green | red/green | red/green | |
| Violet | blue | Violet | Black | |
Bending radius | |||||
| 37.5 mm | 37.5 mm | 75 mm | 30 mm | |
| 75 mm | 75 mm | 150 mm | 60 mm | |
Tensile load maximum | 100 N | 100 N | 100 N | 100 N | |
Weight per length | 80 kg/km | 80 kg/km | 71 kg/km | 67 kg/km | |
Permitted ambient conditions | |||||
Ambient temperature | |||||
| -40 ... +75 °C | -40 ... +75 °C | -40 ... +60 °C | -40 ... +60 °C | |
| -40 ... +75 °C | -40 ... +75 °C | -40 ... +60 °C | -40 ... +60 °C | |
| -40 ... +75 °C | -40 ... +75 °C | -40 ... +60 °C | -40 ... +60 °C | |
| -40 ... +75 °C | -40 ... +75 °C | -40 ... +60 °C | -40 ... +60 °C | |
| Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | |
Burning behavior | flame resistant according to IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4) | flame resistant according to IEC 60332-3-24 (Category C) | flame resistant according to IEC 60332-1 | inflammable | |
Chemical resistance | |||||
| oil resistant according to IEC 60811-2-1 (4 hours / 70°C) | oil resistant according to IEC 60811-2-1 (4 h / 70°C) | oil resistant according to IEC 60811-2-1 (7x24h/90°C) | oil resistant according to IEC 60811-2-1 (4 h / 70°C) | |
| Conditional resistance | Conditional resistance | resistant | Conditional resistance | |
| conditional resistance | conditional resistance | conditional resistance | conditional resistance | |
Radiological resistance to UV radiation | resistant | resistant | resistant | resistant | |
Product properties, functions, components general | |||||
Product feature | |||||
| No | No | No | No | |
| Yes | Yes | Yes | Yes | |
Standards, specifications, approvals | |||||
UL/ETL listing 300 V Rating | Yes; c(UL)us, CMG / CL3 / Sun Res | Yes; CMG / CL3 / Sun Res | Yes; c(UL)us, CMX | No | |
UL/ETL style 600 V Rating | Yes | Yes | No | No | |
Certificate of suitability | |||||
| Yes | Yes | Yes | Yes | |
| Yes | ||||
| Yes | Yes | Yes | Yes | |
Marine classification association | |||||
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No |
Order number | 6XV1830-3FH10 | 6XV1831-2K | 6XV1830-3EH10 | 6XV1831-2L | |
---|---|---|---|---|---|
Product type designation | PROFIBUS FC Ground Cable | PROFIBUS FC Flexible Cable | PROFIBUS FC Trailing Cable | PROFIBUS FC Trailing Cable | |
Product description | Special bus cable (2-core) with additional protective jacket, sold by the meter, unassembled | Flexible bus cable (2-core), sold by the meter, unassembled | Highly flexible bus cable (2-core), sold by the meter, unassembled | Highly flexible bus cable (2-core), sold by the meter, unassembled | |
Suitability for use | Used for buried cables | For occasionally moved machine parts | Continuous motion control in a cable carrier | Continuous motion control in a cable carrier | |
Cable designation | 02YSY (ST) CY2Y 1x2x0,64/2,55-150 SW KF 40 | 02YH (ST) C11Y 1x2x0,65/2,56-150 LI KF40 FRNC FC VI | 02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR petrol | 02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR VT FC | |
Electrical data | |||||
Damping ratio per length | |||||
| 2.5 dB/km | 3 dB/km | 3 dB/km | 3 dB/km | |
| 4 dB/km | 4 dB/km | 4 dB/km | 4 dB/km | |
| 22 dB/km | 25 dB/km | 25 dB/km | 25 dB/km | |
| 42 dB/km | 49 dB/km | 49 dB/km | 49 dB/km | |
Impedance | |||||
| 150 Ω | 150 Ω | 150 Ω | 150 Ω | |
| 270 Ω | 270 Ω | 270 Ω | 270 Ω | |
| 185 Ω | 185 Ω | 185 Ω | 185 Ω | |
| 150 Ω | 150 Ω | 150 Ω | 150 Ω | |
Relative symmetrical tolerance | |||||
| 10 % | 10 % | 10 % | 10 % | |
| 10 % | 10 % | 10 % | 10 % | |
| 10 % | 10 % | 10 % | 10 % | |
Loop resistance per length maximum | 110 mΩ/m | 133 mΩ/m | 133 mΩ/m | 133 mΩ/m | |
Shield resistance per length maximum | 9.5 Ω/km | 15 Ω/km | 14 Ω/km | 14 Ω/km | |
Insulation resistance coefficient | 16 000 GΩ·m | ||||
Capacity per length at 1 kHz | 28.5 pF/m | 28 pF/m | 28 pF/m | 28 pF/m | |
Operating voltage | |||||
| 100 V | 100 V | 100 V | 100 V | |
Mechanical data | |||||
Number of electrical cores | 2 | 2 | 2 | 2 | |
Design of the shield | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | |
Type of electrical connection FastConnect | Yes | Yes | Yes | Yes | |
Outer diameter | |||||
| 0.65 mm | 0.67 mm | 0.67 mm | 0.67 mm | |
| 2.55 mm | 2.56 mm | 2.56 mm | 2.56 mm | |
| 5.4 mm | 5.4 mm | 5.4 mm | 5.4 mm | |
| 10.8 mm | 8 mm | 8 mm | 8 mm | |
| The cable (diameter 8.0 mm +-0.4 mm) has an additional black outer cover (diameter 10.8 mm +-0.5 mm) as protection against damage if laid in the ground. because of outer diameter > 8 mm: Bus connectors can only be connected after removing the outer cover. | ||||
Symmetrical tolerance of the outer diameter of cable sheath | 0.5 mm | 0.4 mm | 0.4 mm | 0.4 mm | |
Material | |||||
| PE | PE | PE | PE | |
| PVC | FRNC | PVC | PVC | |
| PE/PVC; PVC (sheath of the cable), PE (additional outer sheath) | PUR (TPE-U) | PUR (TPE-U) | PUR (TPE-U) | |
Color | |||||
| red/green | red/green | red/green | red/green | |
| Black | Violet | petrol | Violet | |
Bending radius | |||||
| 41 mm | 40 mm | 40 mm | 40 mm | |
| 81 mm | 120 mm | |||
| 120 mm | 120 mm | |||
Number of bending cycles | 3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 120 mm (15x D), a speed of 4 m/s and an acceleration of 4 m/s² | 3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 120 mm (15x D) and an acceleration of 4 m/s² | |||
Tensile load maximum | 100 N | 100 N | 100 N | 100 N | |
Weight per length | 117 kg/km | 70 kg/km | 77 kg/km | 77 kg/km | |
Permitted ambient conditions | |||||
Ambient temperature | |||||
| -40 ... +60 °C | -20 ... +60 °C | -40 ... +60 °C | -40 ... +60 °C | |
| -40 ... +60 °C | -40 ... +60 °C | -40 ... +60 °C | -40 ... +60 °C | |
| -40 ... +60 °C | -40 ... +60 °C | -40 ... +60 °C | -40 ... +60 °C | |
| -40 ... +60 °C | -40 ... +60 °C | -40 ... +60 °C | -40 ... +60 °C | |
| Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | |
Ambient condition for operation | Limited segment length (see manual for PROFIBUS networks) | Limited segment length (see manual for PROFIBUS networks) | Limited segment length (see manual for PROFIBUS networks) | ||
Burning behavior | inflammable | flame resistant according to IEC 60332-1-2 | flame resistant according to IEC 60332-1-2 | flame resistant according to IEC 60332-1-2 | |
Chemical resistance | |||||
| oil resistant according to IEC 60811-2-1 (4 hours / 70°C) | oil resistant according to IEC 60811-2-1 (7x24h/90°C) | oil resistant according to IEC 60811-2-1 (7x24h/90°C) | oil resistant according to IEC 60811-2-1 (7x24h/90°C) | |
| Conditional resistance | resistant | resistant | resistant | |
| conditional resistance | conditional resistance | conditional resistance | conditional resistance | |
Radiological resistance to UV radiation | resistant / Sunlight resistant acc. to UL 444 Sec. 7.12 | resistant | resistant | resistant | |
Product properties, functions, components general | |||||
Product feature | |||||
| No | Yes | No | No | |
| Yes | Yes | Yes | Yes | |
Standards, specifications, approvals | |||||
UL/ETL listing 300 V Rating | No | Yes; c(UL)us, CMX | Yes; c(UL)us, CMX | Yes; CMX | |
UL/ETL style 600 V Rating | No | No | No | No | |
Certificate of suitability | CE, FCC, IC, cULus, Ex approval only together with 6GT2801-4AB10 | ||||
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
Marine classification association | |||||
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No |
Order number | 6XV1830-0LH10 | 6XV1830-3GH10 | 6XV1830-0PH10 | 6XV1830-0MH10 | |
---|---|---|---|---|---|
Product type designation | PROFIBUS FC FRNC Cable GP | PROFIBUS Festoon Cable GP | PROFIBUS Torsion Cable | SIENOPYR FR ship cable | |
Product description | Flame retardant, halogen-free bus cable (2-core), sold by the meter, unassembled | Flexible bus cable (2-core), sold by the meter, unassembled | Highly flexible bus cable (2-core), sold by the meter, unassembled | Bus cable (2-core), sold by the meter, unassembled | |
Suitability for use | Halogen-free cable, suitable for use in buildings | Specially for festoon attachment | For use in moving machine components | Cable for fixed installation on ships and offshore facilities in all enclosed spaces and on open decks. This cable cannot be used for permanent installation in water. | |
Cable designation | 02YSH (ST) CH 1x2x0,64/2,55-150 VI KF 25 FRNC FC | 02YS (ST) CY 1 x 2 x 0,65/2,56 LI petrol FR | 02Y (ST) C 11Y 1x2x0,8/2,56-150 LI FR VI | M-02Y (ST) CH X 1 x 2 x 0,35 100 V | |
Electrical data | |||||
Damping ratio per length | |||||
| 2.5 dB/km | 3 dB/km | 2.5 dB/km | 3 dB/km | |
| 4 dB/km | 4 dB/km | 3 dB/km | 5 dB/km | |
| 22 dB/km | 25 dB/km | 25 dB/km | 22 dB/km | |
| 42 dB/km | 49 dB/km | 49 dB/km | 45 dB/km | |
Impedance | |||||
| 150 Ω | 150 Ω | 150 Ω | 150 Ω | |
| 270 Ω | 270 Ω | 270 Ω | 250 Ω | |
| 185 Ω | 185 Ω | 185 Ω | 185 Ω | |
| 150 Ω | 150 Ω | 150 Ω | 150 Ω | |
Relative symmetrical tolerance | |||||
| 10 % | 10 % | 10 % | 10 % | |
| 10 % | 10 % | 10 % | 10 % | |
| 10 % | 10 % | 10 % | 10 % | |
Loop resistance per length maximum | 110 mΩ/m | 133 mΩ/m | 98 mΩ/m | 110 mΩ/m | |
Shield resistance per length maximum | 9.5 Ω/km | 19 Ω/km | 14 Ω/km | ||
Insulation resistance coefficient | 16 000 GΩ·m | 16 000 GΩ·m | 16 000 GΩ·m | ||
Capacity per length at 1 kHz | 28.5 pF/m | 28 pF/m | 29 pF/m | ||
Operating voltage | |||||
| 100 V | 100 V | 100 V | 100 V | |
Mechanical data | |||||
Number of electrical cores | 2 | 2 | 2 | 2 | |
Design of the shield | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | |
Type of electrical connection FastConnect | Yes | No | No | No | |
Outer diameter | |||||
| 0.65 mm | 0.67 mm | 0.8 mm | 0.67 mm | |
| 2.55 mm | 2.56 mm | 2.56 mm | ||
| 5.4 mm | 5.8 mm | 6 mm | 8 mm | |
| 8 mm | 8 mm | 8 mm | 9.8 mm | |
| Outer diameter > 8 mm: Bus connectors can only be connected after removing the outer cover | ||||
Symmetrical tolerance of the outer diameter of cable sheath | 0.4 mm | 0.3 mm | 0.4 mm | 0.5 mm | |
Material | |||||
| PE | PE | PE | PE | |
| FRNC | Halogen-free polymer (HM4) | |||
| FRNC | PVC | PUR (TPE-U) | Halogen-free, cross-linked polymer | |
Color | |||||
| red/green | red/green | red/green | red/green | |
| Violet | petrol | Violet | Black | |
Bending radius | |||||
| 60 mm | 30 mm | 30 mm | 98 mm | |
| 80 mm | 196 mm | |||
| 70 mm | 60 mm | |||
Number of bending cycles | Not suitable for garland usage | ||||
Number of torsion cycles with torsion by ± 180° on 1 m cable length | 5 000 000 | ||||
Tensile load maximum | 100 N | 80 N | 100 N | 100 N | |
Weight per length | 72 kg/km | 64 kg/km | 65 kg/km | 110 kg/km | |
Permitted ambient conditions | |||||
Ambient temperature | |||||
| -25 ... +80 °C | -40 ... +80 °C | -25 ... +75 °C | -35 ... +80 °C | |
| -25 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | -35 ... +80 °C | |
| -25 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | -35 ... +80 °C | |
| -25 ... +80 °C | -40 ... +80 °C | -25 ... +75 °C | -15 ... +80 °C | |
| Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 | |
Ambient condition for operation | At ambient temperatures below -15 °C, the cable must not be subjected to any movements other than the normal vibration levels encountered on board ship | ||||
Burning behavior | flame resistant according to IEC 60332-3-24 (Category C), IEC 60332-3-22 (Category A), EN 50267-2-1/2, IEC 61034 | flame resistant according to IEC 60332-3-24 (Category C) | flame resistant according to IEC 60332-1-2 | flame resistant according to IEC 60332-3-24, IEC 607542, IEC 61031, DIN VDE 0472 Part 805 Prüfart B | |
Chemical resistance | |||||
| oil resistant according to IEC 60811-2-1 (4 h / 70°C) | conditional resistance | oil resistant according to IEC 60811-2-1 (7x24h/90°C) | resistant to diesel fuel according to DIN VDE 51601, ASTM oil No. 2 according to DIN 53521, oil, NATOCode 0178, BWTL 91500031/2 according to VG 95214 Part 4, hydraulic fluid, NATOCode H515, BWTL 91500020 according to VG 95214 Part 4, cold cleaning solvent, BW-TL 68500017 according to VG 95214 Part 4, deionized water according to VG 95214 Part 4, deionized water with 3.5% NaCl | |
| Conditional resistance | Conditional resistance | resistant | resistant | |
| conditional resistance | conditional resistance | conditional resistance | conditional resistance | |
Radiological resistance to UV radiation | resistant | resistant | resistant | resistant | |
Product properties, functions, components general | |||||
Product feature | |||||
| Yes | No | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
Standards, specifications, approvals | |||||
UL/ETL listing 300 V Rating | Yes; c(UL)us, CM / CL3 / Sun Res | Yes; CMG / PLCT / Sun Res / Oil Res | Yes; CMX | No | |
UL/ETL style 600 V Rating | Yes | Yes | No | No | |
Certificate of suitability | |||||
| Yes | Yes | Yes | ||
| Yes | Yes | |||
Marine classification association | |||||
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | Yes | |
| No | No | No | Yes | |
| No | No | No | Yes | |
| No | No | No | No | |
| No | No | No | No |
Order number | 6XV1860-2R | 6XV1860-2S | |
---|---|---|---|
Product type designation | PROFIBUS Hybrid Standard Cable GP | PROFIBUS Hybrid Robust Cable | |
Product description | Hybrid cable (data and energy wires), product sold by meter, unassembled | Hybrid cable (data and energy wires), product sold by meter, unassembled | |
Suitability for use | Trailing-type, hybrid cable used for supplying data and power to ET 200pro | Rugged cable for supplying data and power to ET 200pro under conditions of high mechanical loading. Cable resistance to weld spatter according to HD22.2 S3 / 5 | |
Cable designation | 02Y(ST)C 1x2x0.65/2.56-150LI LIY-Z Y 2x1x1.5 VI | 02Y(ST)C 1x2x0.65/2.56-150LI LIH-Z 11Y 2x1x1.5 VI FRNC |