国产强伦姧在线观看无码,中文字幕99久久亚洲精品,国产精品乱码在线观看,色桃花亚洲天堂视频久久,日韩精品无码观看视频免费

      產(chǎn)品|公司|采購|資訊

      氫氣分析儀 CONTHOS 3

      參考價面議
      具體成交價以合同協(xié)議為準
      • 公司名稱深圳市昂為電子有限公司
      • 品       牌
      • 型       號
      • 所  在  地深圳市
      • 廠商性質代理商
      • 更新時間2025/5/4 9:13:24
      • 訪問次數(shù)28
      產(chǎn)品標簽:

      在線詢價收藏產(chǎn)品 點擊查看電話

      聯(lián)系我們時請說明是 智能制造網(wǎng) 上看到的信息,謝謝!

      煙氣分析儀,沼氣分析儀,氣體報警器,紅外傳感器模塊
      基于熱導原理的在線式氫氣分析儀,長期穩(wěn)定應用于鋼鐵、冶金行業(yè),化學工業(yè)以及其他需要分析氫氣濃度的領域。該系統(tǒng)反應速度快,低于2秒鐘,并且能保持反應速度的穩(wěn)定。分析系統(tǒng)具有多種版本可選,有機柜式、現(xiàn)場安裝的機箱系統(tǒng),以及具有1區(qū)和2區(qū)EX防爆等級的成套系統(tǒng)提供。可多量程同時測量并自動切換。
      氫氣分析儀 CONTHOS 3 產(chǎn)品信息

      Analytical-/ Operational Data

      Measuring principle

      Difference in thermal conductivity (?λ) of various gases

      Measured quantity

      Concentration of a particular gas component in binary and quasi-binary mixtures.

      In many applications involving multi-component gases the inherent non-selectivity of the thermal conductivity principle can be minimized using interference correction techniques.

      Physical interference reduction is sometimes possible with certain applications due to the wide temperature range of the CONTHOS' TC-detector.

      Measuring ranges

      Up to 3 independently configurable, switchable ranges. The reference response of each range is factory linearized (4th-degree polynomial).

      Suppressed output ranges within the corresponding reference range can be easily configured.

      Range switching is accomplished manually, automatically and/or externally (via optional digital inputs).

      lowest range: 0 - 0.5% H2 in N2 or 99.5-99% H2 in N2 (or equivalent ?λ) largest range: 0 - 99% H2

      Response time τ90

      approx. 2 sec. (dependent upon gas flow and analyzer configuration) (integration time configurable)

      Precision

      ≤ 0.5% F.S.O. (typically better than ± 0.2% F.S.O.)

      Accuracy

      better than ± 0.5% F.S.O. (typically better than ± 0.3% F.S.O.)

      Calibration

      Manual: 2-point (offset/span) calibration Option: automatic or semi-automatic calibration in conjunction with the optional digital I/O-board or RS-485

      Interference correction

      3 correction channels for static and/or dynamic interference correction (dynamic correc tion only in conjunction with the optional analog inputs or RS-485)

      One of the prerequisites for dynamic interference correction is the availability of a selective signal, proportional to the particular gas component to be corrected for. The processing of analyzer ranges with a suppressed zero range is not possible.



      - 鋼鐵、冶金

      - 化學工業(yè)

      - 石油

      - 其他









      在找 氫氣分析儀 CONTHOS 3 產(chǎn)品的人還在看
      返回首頁 產(chǎn)品對比

      提示

      ×

      *您想獲取產(chǎn)品的資料:

      以上可多選,勾選其他,可自行輸入要求

      個人信息:

      Copyright gkzhan.com , all rights reserved

      智能制造網(wǎng)-工業(yè)4.0時代智能制造領域“互聯(lián)網(wǎng)+”服務平臺

      對比欄