Specifications |
Input |
Pressure Range | Vacuum to 400 bar (6000 psi) 0 -25 bar Absolute |
Proof Pressure | 2 x Full Scale (FS) (1.5 x FS for 400 bar, >= 5000) |
Burst Pressure | >35 x FS <= 6 bar (100 psi) >20 x FS >= 60 bar (1000 psi) >5 x FS <= 400 bar (6000 psi) |
Fatigue Life | Designed for more than 100 million FS cycles |
Performance |
Long Term Drift | 0.2% FS/year (non-cumulative) |
Accuracy | 0.25% FS typical (optional 0.15% FS) |
Thermal Error | 1.5% FS typical (optional 1% FS) |
Compensated Temperatures | -20°F to 80°F (-5°C to 180°C) |
Operating Temperatures | -40°C to 125°C (-22°F to 260°F) for elec. codes A, B, C, 1 -20°C to 80°C (-5°F to 180°F) for elec. codes 2, D, G, 3 -20°C to 50°C (-5°F to 125°F) for elec. codes F, M, P |
Zero Tolerance | 1% span |
Span Tolerance | 1% span |
Response Time | 0.5 ms |
Mechanical Configuration |
Pressure Port | See ordering chart |
Wetted Parts | 17-4 PH Stainless Steel |
Electrical Connection | See ordering chart |
Enclosure | 316 SS, 17-4 PH ss IP65 for elec. codes A, B, C, D, G, 1, 2, 3 IP67 for elec. code F IP68 for elec. code M IP30 for elec. code "3" with flying leads |
Vibration | 70g, peak to peak sinusoidal, 5 to 2000 Hz (Random Vibration: 20 to 200 Hz @ =20g Peak per MIL-STD.-810E Method 514.4) |
Acceleration | 100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for 400 bar (6000 psi) range |
Shock | 20g, 11 ms, per MIL-STD.810E Method 516.4 Procedure I |
Approvals | CE, ETL Intrinsically Safe for Class 1, Div. 1, Groups C & D (also available as BASEEFA ATEX intrinsically safe - contact factory for part numbers) |
Weight | Approx. 100 grams (additional; cable 75 g/m) |
Millivolt Output |
Output | 100 mV (10 mv/v) |
Supply Voltage (Vs) | 10 Vdc (15 Vdc max.) Regulated |
Bridge Resistance | 2600-6000 Ohms |
Voltage Output Units |
Output | See ordering chart |
Supply Voltage (Vs) | 1.5 Vdc above span to 35 Vdc @ 6 mA |
Supply Voltage Sensitivity | 0.01% FS/Volt |
Min. Load Resistance Current Consumption | (FS output / 2) K Ohms Approx. 6 mA at 7.5V output |
Current Output Units |
Output | 4-20 mA (2 wire) |
Supply Voltage (Vs) | 24 Vdc, (7-35 Vdc) Above 100°C supply limited to 24 Vdc |
Supply Voltage Sensitivity | 0.01% FS/Volt |
Max. Loop Resistance | (Vs-7) x 50 ohms |