Versions : B-Blind , D-Display
Current output : 0-20mA or 4-20mA Laod max.500 ohms, Forward/reverse measurement
Pulse output : 10,100,1000 pulse/sec (=Hz), Pulse/liter,m3,or US gallons
Pulse width : 50,100,200,500ms selectable (<10Hz)
Local display : 3-Line LCD ( actual flowrate ,forward,reverse and sum totalizers (7-digit )
Power supply : AC110 or 220V 48-63Hz
Housing Materials : Polycarbonate ( PC )
Protection category : IP65 ( NEMA 4 / 4X )
μP-controlled signal converter with digital signal processing
ensures reliability and long-time stability
High-speed signal conversion system (patented) allows flowmeter
application even in difficult cases
Modular signal converter, low-cost basic version without display or
control panel, easy to set and document with every DOS-PC (notebook)
and KROHNE software, error-free
can be optionally fitted with local display and control panel
terminals and all signal converter modules pluggable, easily
replaceable without recalibration or resetting
plus all the numerous functions:
- current, pulse and status indication outputs
- flow measurement in both directions
- low-flow cutoff
- limit signalling or direction identification
- volume flow counting via passive, galvanically
- isolated pulse output
available for AC or DC voltage operation