-Load cells
-Pressure, torque and displacement transducers
Features:
-Front panel calibration and operation
-Simulative or live load calibration
-5 digit high brightness LED display
1.Analog signal Input range Min. 0.5mV/V, Max. 3.2mV/V
2.Non-linearity +0.02% of full scale
3.Internal resolution ±1/200,000
4.Temp. coefficient for Zero-0.25 V/ RTI Max.
transducer or loadcell Span-within 0.01% reading/
5.Excitation for pressure
transducer or loadcell
6.Display
Type LED, 7 segments red, 10mm high
Active digit unit weight (00000~99990),
Polarity indication "-" sign ("-"ranges are limited 30% of F.C)
Display increments 1,2,5,10-selectable
Decimal points Selectable to any points
Status annunciators Zero alarm, auto-zero,
relay point (L1~L4), tare
7.Sampling speed Appr. 30 times per second
Relay output mode
Mode 1: 4 relay outputs, 3 setpoints
Mode 2: 4 relay outputs, 4 setpoints
Mode 3: Relay by external signal
Mode 4: Gross total, 4 relay, 3 setpoints
Mode 5: Gross total, 4 relay, 4 setpoints
9.Operating Voltage AC ll0, 220V select by input power
changeable holder
10.Power Consumption Appr. 18VA
11.Calibration Live load calibration by front panel
push button
12.Hold mode Peak hold (only available on BS4220A),
average hold
13.Interface
1. Analog Output Voltage output (DC 0-10V)
2. Analog Output Current output (DC 4-20mA)
3. Serial Output RS-232C output
14.Weight Appr. 2.3kg
DC 12V, 300mA
8.Set point mode
oC
oC
For:
-Load cells
-Pressure, torque and displacement transducers
Features:
-Front panel calibration and operation
-Simulative or live load calibration
-5 digit high brightness LED display
The BS4200A series multifunction transducer Indicator/Controller are a high performance microprocessor based
digital weight indicator and setpoint controller combined in one package. All setpoint settings are entered via the
front panel keyboard, which in addition to the standard controls for weighing and setpoint entry, also includes
controls for direct keyboard entry.
The basic BS4200A comprises a loadcell amplifier and A/D converter, 4 user configurable output relays and
excitation for up tomsix 350 ohm transducers in parallel. Alternatively, the BS4220A indicator incorporates total
weight display and peak hold function.
The basic BS4200A also accommodates a wide variety of boards providing 4-20A, 0-10V or RS-232C serial output.
Built for rugged industrial use, the BS4200A features a steel enclosure and the unit will operate on 110VAC or
220VAC. Typical applications include weighing, batching, mixing, force, pressure, torque and displacement.