CDI-CPS
The model CDI-CPS accepts the various pulse
type signal (square or sine wave, magnetic sensor
signal etc.)and provides isolated pulse signal
outputs that is devided by user's setting value.
MODEL: CDI-CPS
MODEL TYPE
INPUT
OUTPUT 1
POWER
1 : 1 Output
2 : 2 Output
X : AC 110V or 220V for 50/60Hz
Y : DC 24V
Z : Other special power
- Construction : Plug -in
- Wring : M3.5 Screw Terminal
- Isolation : Power to Input to Output1
to Output2
- Adjustment : Zero & Span± 20%of full scale
- Operating temperature : -5℃ ~ 55℃
- Operating humidity : 90%RH Max
(none condensing)
- Power supply
AC : 110V or 220V/60Hz ±10%,approx 3VA
DC : 18V ~ 30V ±10%,approx 3VA
- Power selection : AC 110V/220V Swich
in the back plane
- Mounting : Wall or DIN rail
- Accuracy : ± 0.2%
- Temp'coefficient : ±0.015/℃
- Response time : 0.5 Sec or less(0~90%)
- Insulation resistance : 100MΩor more
with 500VDC(Input/Output/Power)
- Dielectric strength : 1500VAC at 1minute
(Input to Output to Power)
CDI TECH CO.,LTD.
MODEL CDI - CPS
PULSE TO PULSE SCALER
GENERAL SPECIFICATION
INPUT
- Open collector : 12VDC/4mA
- Voltage pulse : Square or sine waveforms
- Dry contact : 12VDC/4mA
- Current pulse input impedance : 250Ω
- Input cut off bias voltage adjustment
: 0~ 6VDC max
OUTPUT
INSTALLATION
PERFORMANCE
ORDERING CODE SELECTION
OUTPUT 2
N : no output2
The codes are the same as Output1
CHUMDAN INSTRUMENT & TECHNOLOGY CO.,LTD. PAGE 40
1 : Voltage pulse
2 : Open collector
3 : Dry contact
O : Other spec.
- Open collector : 24VDC/50mA
Frequency range : 0~ 10KHz
- Voltage pulse
Level:High -- V±10%
Low -- 0 ≤0.5V
Load impedance : 600Ωmax
- Dry contact : 250VAC/3A ,30VDC/5A
- Current pulse : 0 ~ 20mA/DC Standard
The model CDI-CPD accepts the various pulse
type signal (square or sine wave, magnetic sensor
signal etc.)and provides isolated pulse outputs.
MODEL: CDI-CPD
MODEL TYPE
INPUT
OUTPUT 1
POWER
1 : 1 Output
2 : 2 Output
X : AC 110V or 220V for 50/60Hz
Y : DC 24V
Z : Other special power
- Construction : Plug -in
- Wring : M3.5 Screw Terminal
- Isolation : Power to Input to Output1
to Output2
- Adjustment : Zero & Span± 20%of full scale
- Operating temperature : -5℃ ~ 55℃
- Operating humidity : 90%RH Max
(none condensing)
- Power supply
AC : 110V or 220V/60Hz ±10%,approx 3VA
DC : 18V ~ 30V ±10%,approx 3VA
- Power selection : AC 110V/220V Swich
in the back plane
- Mounting : Wall or DIN rail
- Accuracy : ± 0.2%
- Temp'coefficient : ±0.015/℃
- Response time : 0.5 Sec or less(0~90%)
- Insulation resistance : 100MΩor more
with 500VDC(Input/Output/Power)
- Dielectric strength : 1500VAC at 1minute
(Input to Output to Power)
CDI TECH CO.,LTD.
MODEL CDI - CPD
PULSE TO PULSE DISTRIBUTOR
GENERAL SPECIFICATION
INPUT
- Open collector : 12VDC/4mA
- Voltage pulse : Square or sine waveforms
- Dry contact : 12VDC/4mA
- Current pulse input impedance : 250Ω
- Input cut off bias voltage adjustment
: 0~ 6VDC max
OUTPUT
INSTALLATION
PERFORMANCE
ORDERING CODE SELECTION
OUTPUT 2
N : no output2
The codes are the same as Output1
CHUMDAN INSTRUMENT & TECHNOLOGY CO.,LTD. PAGE 38
1 : Voltage pulse
2 : Open collector
3 : Dry contact
O : Other spec.
- Open collector : 24VDC/50mA
Frequency range : 0~ 10KHz
- Voltage pulse
Level:High -- V±10%
Low -- 0 ≤0.5V
Load impedance : 600Ωmax
- Dry contact : 250VAC/3A ,30VDC/5A
- Current pulse : 0 ~ 20mA/DC Standard