| Model | US2P-5000xxx | US2P-7500xxx | US2P-10Kxxx | Capacity | 5KVA/3.3KW | 7.5KVA/5KW | 10KVA/6.6KW | Topology | Synchronous On-line | | Input | Voltage range | (100/110/220/230Vac) ± 15% | Frequency | 50/60Hz ±3Hz | Phase (Φ) | 1P 2W + GND | Output | Voltage | Inverter Mode : (100/110/220/230Vac) ± 2% | Waveform | Pure Sine Wave | Voltage stability | Rated Voltage ± 2% | Frequency | 50/60Hz ± 0.5Hz (Inverter Mode) | Freq. select | 50/60Hz (Operator setting) | Over load | Shutdown after 1 minute in the condition of 120% load / Auto recovery | Over current | Auto shutdown in the condition of 300% load / Auto recovery | THD | 5% Max (linear load) | Transfer time | 2ms Max | Efficiency | Inverter mode : 80%(99% linear load), Line mode : 95% (99% linear load) | | Discharging | 10min,99% load, 30min, 50% load | Battery(External) | 16 * 12VDC/20AH | 16 * 12VDC/30AH | 16 * 12VDC/40AH | Battery type | No maintenance, Sealed Lead-Acid | Charging (95%) | 5 Hr | 7 Hr | 9 Hr | Display &indicator Specification | Supply Mode | Line Mode/ Inverter Mode/ System fault | LCD | Barrery voltage, Charging and discharging current, Ouput voltage Output current, Input voltage, Input current, Frequency Number of P.F., Overload, Over current, Abnormal Condition | Alarm | Inverter Mode, Low vattery level, Overload, Over current, Abnormal Condition | Fault Scan | Memory fault information of 10 times. | Communication(Option) | RS232Port : Windows, Linux, NT (Remote control) SNMP and Multi control with WEB | | Size (H x W x Dmm) | 530*280*580 | 590*300*670 | 590*300*670 | Weight (kgs) | | Safety | | According to cUL,CE | Environment | Acoustic Noise | 60[dB] Max | Operation | 0℃ ~40℃, 0 ~90%RH, Non Condensing | Storage | -20℃ ~60℃, 0 ~95%RH, Non Condensing | Warranty | 2 years (Battery : 6 months) | | | | Model Name | OKUR-1000A | OKUR-1500A | OKUR-2200A | OKUR-3000A | Capacity(VA/W) | 1000VA/ 660W | 1500VA/ 975W | 2200VA/ 1430W | 3000VA/ 2100W | Topology | Line interactive | Feature | Hi-capacity smart charger, AC auto restart Audible alarm, Alarm silence, User eplacement vattery, Automatic voltage regulation.
| | Input | Voltage Range | Rated Voltage +/-20% | Frequency | 50/60Hz +/-3Hz (Auto sensing) | Phase(Φ) | Single phase (1P 2W +G) | Output | Voltage Range | Back-up Mode : Rated Voltage (100/110/220/230 Vac) +/-2% Line mode : Rated Voltage +/-10% | Frequency | 50/60Hz +/-0.5Hz (Inverter mode), 50/60Hz (Ato tracking) | Waveform | Pure sine wave | Overload | 120% for 1 min | Harmonic Distortion | 3% at full 1 min | Transfer time | 4 ms max | | Battery back-up lime (half-load) | 7 min | 7 min | 10 min | 7 min | Battery Rating | 24VDC 7AH Internal Battery | 36VDC 7AH Internal Battery | 48VDC 12AH External Battery | 48VDC 12AH External Battery | Battery type | Sealed Lead-Acid, No maintenance | Recharge time (95%) | 3 hours after full discharge | Environment | Ambient Temperature | Operating: 0~40℃ (32~104℃) Storage: -15~45℃ (5~113℃) | Relative Humidity | 0 ~ 90% operating with non-condensing 0 ~ 95% Storage with non-condensing | Operating Altitude | UP to 1500m (5000 ft) | Audible noise | <45dB @ 1m | | Dimension(mm) (H x W x D) | 88*483*440 (19" Rack,2U) | 133x483x460 (19" Rack,3U) | Weight (kgs) | 22 | 15 (UPS module only) | 17 (UPS module only) | 20 (UPS module only) | Display and Indicator | LED | 5-Load Levels, 5-Battery Levels, Line Boost, Line Buck, Inverter Mode, Line Mode, Over Load, Battery Low Voltage | LCD (option) | input Voltage/Current, Output Voltage/Current, Output Frequency, Battery Voltage/Current, Charging Rate, Times of Power Failure | Alarm | Inverter mode (2sec periodically), Low Battery voltage (1 sec periodically) Abnormal Conditions (continuous) | Safety | According to cUL.CE | Warranty | 2years (Battery : 6months) | Interface | RS232 or Relay Contact Type. | | Model | UL2R - 1000xxx | Capacity | 1000VA/660W | Topology | Line Interactive | | Input | Voltage range | (100/110/220/230Vac) ± 20% | | 50/60Hz ±3Hz | Phase (Φ) | 1P 2W + GND | Output | Voltage | Inverter Mode : (100/110/220/230Vac) ± 2% | Waveform | Pure Sine Wave | Frequency | 50/60Hz ± 0.5Hz (Inverter Mode), 50/60Hz(Auto tracking) | Over load | Shutdown after 1 minute in the condition of 120%/Auto recovery | Over current | Auto shut down in the condition over 300% load | THD | 5% max (Linear load) | Transfer time | 10ms max. (4ms Typical) | Efficiency | Inverter mode : 80% (50% load) Line mode : 98% (99% load) | | Discharging | 3 Minute /50% load | Battery | 4*12VDC / 2AH (Internal) | Battery type | No maintenance, Sealed Lead-Acid | Charging(95%) | 20 Minute | Display & indicator Specification | LED Display | 5-Load Levels, 5-Battery Levels, Line Boost, Line Buck, Inverter Mode Line Mode, Over Load, Battery Low Voltage | Alarm | Inverter mode (input abnormal), Battery low, Abnormal Condition | Communication (Option) | RS232 Port : Window, Linux, NT (Remote control) SNMP and Multi control with web site | | Size (H x W x Dmm) | 44*483*440 | Weight t(kgs) | 17 | Safety | | According to cUL,CE | Environment | Acoustic Noise | 45 [dB] Max | Operation | 0℃ ~40℃, 0 ~90%RH, Non Condensing | Storage | -20℃ ~60℃, 0 ~95%RH, Non Condensing | Warranty | 2years (Battery : 6months) | | Model | UL2P-3000xxx | UL2P-5000xxx | UL2P-7500xxx | UL2P-10Kxxx | Capacity | 3000VA/2100W | 5000VA/3500W | 7500VA/5250W | 10KVA/7000W | Topology | Line Interactive | | Input | Voltage range | (100/110/220/230Vac) ± 20% | Frequency | 50/60Hz ±3Hz | Phase (Φ) | 1P 2W + GND | Output | Voltage | Inverter Mode : (100/110/220/230Vac) ± 2% | Waveform | Pure Sine Wave | Frequency | 50/60Hz ± 0.5Hz (Inverter Mode), 50/60Hz(Auto tracking) | Over load | Shutdown after 1 minute in the condition of 120% / Auto recovery | Over current | Auto shutdown in the condition over 300% | THD | 5% Max (Linear load) | Transfer time | 10ms Max | Efficiency | Inverter mode : 80%(50% Linear load), Line mode : 95%(99% Linear load) | | Discharging | 7min. : 99% | 5min. : 99% | 7min. : 99% | 8min. : 99% | 25min. :? 50% | 20min. :? 50% | 29min. :? 50% | 33min :? 50% | Battery(External) | 4*12VDC/26AH (Internal) | 16 * 12VDC/7AH (Internal) | 16 * 12VDC/18AH (External) | 16 * 12VDC/26AH (External) | Battery type | No maintenance, Sealed Lead-Acid | Charging (95%) | 2hr. 30min. | 2hr. 30min. | 5hr. 30min. | 7hr | Display &indicator Specification | LED Display | Display Loading and Charging by 5 steps with LED, Overload, INVERTER MODE, LINE MODE, Battery fault, LINE input BOOST/BUCK Alarm Inverter mode (Input abnormal), Battery low, | Alarm | Inverter mode (Input abnormal), Battery low, Abnormal Condition
| Communication(Option) | RS232 Port ; Windows, Linux, NT (remote control) SNMP and multiple control with web site | | Size (H x W x Dmm) Included Wheel | 530x280x630 | 530x280x630 | 420x300x670 | 420x300x670 | Weight (kg) | | Safety | | According to cUL,CE | Environment | Acoustic Noise | 45[dB] Max | Operation | 0℃ ~40℃, 0 ~90%RH, Non Condensing | Storage | -20℃ ~60℃, 0 ~95%RH, Non Condensing | Warranty | 2 years (Battery : 6 months) | | | | Model Name | OKUR-1000A | OKUR-1500A | OKUR-2200A | OKUR-3000A | Capacity (VA/W) | 1000VA/ 660W | 1500VA/ 975W | 2200VA/ 1430W | 3000VA/ 2100W | Topology | Line interactive | Feature | Hi-capacity smart charger, AC auto restart, Audible alarm Alarm silence, User replacement battery, Automatic voltage regulation.
| | Input | Voltage Range | Rate Voltage +/-20% | Frequency | 50/60Hz ±3Hz(Auto tracking) | Phase (Φ) | Single phase (1P 2W +G) | Output | Voltage Range | Back-up Mode : Rated Voltage (100/110/220/230 Vac) +/-2% Line mode : Rated Voltage +/-10% | Frequency | 50/60Hz ±0.5Hz (Inverter mode), 50/60Hz (Auto tracking) | Waveform | Pure sine wave | Overload | 120% for 1 min | Harmonic Distortion | 3% at full linear load | Transfer time | 4 ms max | | Battery back-up time (50% load) | 10 min | 7 min | 10 min | 7 min | Battery Rating | 24VDC 12AH Internal Battery | 36VDC 7AH Internal Battery | 48VDC 12AH External Battery | 48VDC 12AH External Battery | Battery type | Sealed Lead-Acid,No maintenance | Recharge time (95%) | 3 hours after full discharge | Emvironment | Ambient Temperature | Operating: 0~40℃ (32~104℃) Storage: -15~45℃ (5~113℃) | Relative Humidity | 0 ~ 90RH% Operating with non-condensing 0 ~ 95RH% Storage with non-condensing | Operating Altitude | UP to 1500m (5000 ft) | Audible noise | <45dB @ 1m | | Dimension(mm)(H x W x D) | 220*170*465 | 220*170*465 | 220*170*465 | 220*170*465 | Weight (kgs) | 22 | 24 | 15(ups module only) | 20(ups module only) | Display and Indicator | LED | 5-Load Levels, 5-Battery Levels, Line Boost, Line Buck, Inverter Mode Line Mode, Over Load, Battery Low Voltage | Alarm | Inverter mode (2sec,periodically), Low Battery voltage (1 sec periodically) | Safety | According to cUL,CE | Warranty | 2years (Battery : 6months) | Interface | RS232 or Relay Contact Type | | | |