SCR-50S SCR-80S SCR-100S SCR-125S SCR-200S SCR-300S SCR-400S直流接觸器繼電器
DC Contactor Relays |
◆ Summary SANGWON’s POWNIX Contactor which is used for Power System, Telecommunication appliance equipment has the series of 30, 50, 80, 125, 200, 250, 400, 600, 800, 1000, 1200, 1500, 1800A. |
▷ Most suitable for Battery Charge Circuit : Pick Up 60% ~ rated Voltage
▷ Auxiliary Contact attachment: According to customer’s order
▷ Magnetic Blowout (DC 90V)
▷ Coil can be continuously used.
▷ Mounting Bracket: Easy Installation
▷ Suppresses Coil Surge: Diode can suppress the Surge created when Coil OFF
▷ High Contact Capacity
▷ Magnetic Latch Type available → One shot Pulse: Coil On,
Power Loss of Coil is unnecessary due to the ON state of Main Contact by the Magnetic Latch → One Shot Negate Pulse : Coil On
However, Main Contact is still in ON position even though Power is OFF, so please be careful in handling
Standard, Change-over type
Type | SCR-50S | SCR-80S | SCR-100S | SCR-125S | SCR-200S | SCR-300S | SCR-400S | |
Rated Current(A) | 50A | 100A | 125A | 200A | 300A | 400A | ||
Rated Voltage(V) | DC 60V | |||||||
Voltage Drop between contacts(mV) | 15mV at 100A | |||||||
Operating Voltage(V) | DC 12V, 24v, 30V, 48V, 60V | |||||||
Pull-in Voltage(V) | Under 75% of Operating Voltage | |||||||
Drop-out Voltage(V) | Under 10% of Operating Voltage | |||||||
Power Consumption(W) | 5 ~ 7 | |||||||
Aux. Contact | 4A at DC 24V, 1A at DC 60V, 0.5A at DC 125V |
Magnetically Latching
Type | SCR-50S | SCR-80S | SCR-100S | SCR-125S | SCR-200S | SCR-300S | SCR-400S |
Rated Current(A) | 50A | 80A | 100A | 125A | 200A | 300A | 400A |
Rated Voltage(V) | DC 60V | ||||||
Voltage Drop between contacts(mV) | 15mV at 100A | ||||||
Operating Voltage(V) | DC 12V, 24v, 30V, 48V, 60V | ||||||
Pull-in Voltage(V) | Under 75% of Operating Voltage | ||||||
Drop-out Voltage(V) | Under 10% of Operating Voltage | ||||||
Power Consumption(W) | 5 ~ 7 | ||||||
Aux. Contact | 4A at DC 24V, 1A at DC 60V, 0.5A at DC 125V |
Type : SCR-□ T Type
▷ Most suitable for Battery Charge Circuit : Pick Up 60% ~ rated Voltage
▷ Auxiliary Contact attachment: According to customer’s order
▷ Magnetic Blowout (DC 90V)
▷ Coil can be continuously used.
▷ Mounting Bracket: Easy Installation
▷ Suppresses Coil Surge: Diode can suppress the Surge created when Coil OFF
▷ High Contact Capacity
▷ Magnetic Latch Type available → One shot Pulse: Coil On,
Power Loss of Coil is unnecessary due to the ON state of Main Contact by the Magnetic Latch → One Shot Negate Pulse : Coil On
However, Main Contact is still in ON position even though Power is OFF, so please be careful in handling.
Standard, Change-over type
Type | SCR-100T | SCR-200T | SCR-300T | SCR-400T |
Rated Current(A) | 100A | 200A | 300A(260A) | 400A |
Rated Voltage(V) | DC 60V | DC 80V | ||
Voltage Drop between contacts(mV) | 15mV at 100A | |||
Operating Voltage(V) | DC 12V, 24v, 30V, 48V, 60V | |||
Pull-in Voltage(V) | Under 75% of Operating Voltage | |||
Drop-out Voltage(V) | Under 10% of Operating Voltage | |||
Power Consumption(W) | 5 ~ 7 | |||
Aux. Contact | 4A at DC 24V, 1A at DC 60V, 0.5A at DC 125V |
Magnetically Latching
Type | SCR-100T | SCR-200T | SCR-300T | SCR-400T |
Rated Current(A) | 100A | 200A | 300A(260A) | 400A |
Rated Voltage(V) | DC 60V | DC 80V | ||
Voltage Drop between contacts(mV) | 15mV at 100A | |||
Operating Voltage(V) | DC 12V, 24v, 30V, 48V, 60V | |||
Pull-in Voltage(V) | Under 75% of Operating Voltage | |||
Drop-out Voltage(V) | Under 10% of Operating Voltage | |||
Power Consumption(W) | 5 ~ 7 | |||
Aux. Contact | 4A at DC 24V, 1A at DC 60V, 0.5A at DC 125V |