| | | | 1.Multi-ground fault relay(GFR) is multi-functional and is able to detect ground faults monitoring circuit and is displayed leakage in the circuit and fault current when earthing. 2.It is installed 8 bit MCU with A/D conventer and is configured to perform advanced functions for high reliability. 3.It is a collective device that is intergrated many ground fault detector of conventional single unit. 4.It is capable to detect from minor grounding fault current(0.1A) to medium level fault current (10A) 5.It is configured to have operating time taps for adjustment of time setting and is easy for protection coordination of distribution cirruit. | | | | 6.As wide display and indicators, it is able to enhance checking up and performance. 7.Watch dog function assures ? free operation. 8.The memory stores the last record of ground fault current of each circuit to facilitate following up in the event of accidents. 9.The ABS casing newly adopted offers improved durabillty and extend life of product. 10.All GFRs are tested EMC to ensures and high frequency & surge do not interfere design performance of GFR. | | | Items | DGF M10 (For 10Circuits) | DGF-M05(For 5 Circuits) | Testing Institute | Korea Electric Research Institute | Usage | for Protection against minor and Major Ground Leakage Faults | Control Power Voltage | AC110/220V Operable in common or AC 240V | Frequency | 50/60 Hz Operable in Common | Operating Current Setting | 9Steps, of 0.1, 0.3, 0.5, 1, 2, 3, 5, 10 and Lock T: 70% TO 99% of Current Setting | Operating Time Setting | 9Steps, of 0.05, 0.1, 0.3, 0.5, 1, 2, 3, 5, 10sec T: ±10% TO 0.05 T=0.1±25ms | Ground Fault Detection Circuit | 10 Circuits | 5 Circuits | Operating Status indicator | LED(Red) and Digital Display one for each Circuit | Resetting | Autu/Manual | Ambient Temperature | -10℃~+50℃ | Vibration Resistance | Energized : Full vibration width 4mm, 1000rpm, 10min Deenergized : Full vibration width 4mm, 1000rpm, 60min | Impact Resistance | Impact Strenght of 300㎨ applied to 3 axial directions of right & Left, up & down, and behind & Forward | Common Frequency Dielecric Resistance | Opn Cirr-Casing : AC 2000V Opn Cir-Opn Cir : AC 2000V Test Cir-Terminals : AC 1000V | ┓ ┣ 60Hz, 1MIN ┛ | Insulating Resistance | Opn Cirr-Casing : 10㏁ or more Opn Cir-Opn Cir : 10㏁ or more Test Cir-Terminals : 10㏁ or more | ┓ ┣ BY DC 500V MEGGER ┛ | Power consumption | 7VA | 5VA | Contact Capacity | AC 125V 5A / DC 30V 5A | Weight | 2.0Kg | 1.7Kg | ZCT(Input) | ZCT Rating 200mA/100mA (ZR, ZS, ZB, type 사용) | | | | 1Multi Function Ground Fault Relay DGF-M10/M05T 1contents: 1.Multi-ground fault relay(GFR) is multi-functional and 1is able to detect ground faults monitoring circuit and is displayed 1leakage in the circuit and fault current when earthing. 12.It is installed 8 bit MCU with A/D ... |