| | | | 1.Multi type earth leakage detector has alarm or CB trip function with detecting multi circuit leakage. 2.As equipped with MCU (A/D converter) at main circuit, it is multi function earth leakage alarm unit with digital display for detection circuit. 3.Available to check leakage current amount and leakage lines. 4.As equipped with self detecting system, easy to check operation condition stably with various LED indication function. 5.Self detecting and checking system make it be easy to inspect internal circuit. | | | | | Description | Micom type | Analog Type | Model No | DED-M10(10C) | DED-M05(5C) | DED-A10(10C) | DED-A05(5C) | Type approval No | 92-1-1 | 97-1-1 | | AC: 110/220V in common | Rated operating frequency | 50/60 Hz | Nominal operating current(A) | 0.2~0.5~1.0A(3 steps) ZCT Input: 200mA/100mA | Current | Operating | 53%~75% of nominal operating current (only if DAI YUN's current transformer is used) | Non operating | 52% of nominal operating current (only if DAI YUN's current transformer is used) |
Aux Power supply voltage | 80%~120% of rated supply voltage | Warning circuit voltage | Below AC 600V | LED indicator | Leakage level: Digital Leaking circuit: Digital, RED LED Warning: RED LED Power supply: GREEN DED ZCT continuity: YELLOW LED Cont / Auto-alarm: YELLOW LED Buzzer alarm: YELLOW LED | Leaking circuit: RED LED Warning: RED LED Power supply: GREEN DED ZCT continuity: YELLOW LED Cont / Auto-alarm: YELLOW LED Buzzer alarm: YELLOW LED | Power consumption | 3.5AV | 3.0VA | 8AV | 6VA | Operating | 6.0AV | 5.5AV | 9AV | 7VA | Ambient temperature | -10℃(Thru +50℃) | Sound level | Buzzer (more than 75 dB) | Insulation resistance | Primary Secondary Primary | - Case - Case Secondary | ┓ ┣ 100MΩ or more(Tested by 500V megger) ┛ | Dielectric strength | Primary Secondary Primary | - Case : 1500V - Case : 500V - Secondary : 1500V | ┓ ┣ AC 60Hz. 1miniute ┛ | Impulse wave withstand voltage | Between terminals Power supply terminals to case | ┓Peak value 6.0kV. Duration of wave front: 0.5~1.5ms ┛Duration of wave tail: 30~50ms and up | Vibration strength | On duty : Full wave width 1mm. 1000rpm. 10min. Not on duty : Full wave width 4mm 1000rpm 60min | Mechanical shock resistance | On duty : natural drop 15times Not on duty : Accelebration of 5kg Max force in any direction for 5 times | Contact point capacity | 1a: AC 250V, 0.5A or DC 30V, 2A / contact | Rate of fuse | 0.1A | 0.2A | Weight | 1.9Kg | 1.7Kg | 2Kg | 1.9Kg | Case | ABS Resin / Black N1.5 | Mounting method | Flush mounting | | | | 1Earth Leakage Detector and Relay DED-M10/A10 1contents: 1.Multi type earth leakage detector has alarm or CB trip 1function with detecting multi circuit leakage. 12.As equipped with MCU (A/D converter) at main circuit, it is 1multi function earth leakage alarm unit with digital display f |