| | | | | | | | | This is oscillating coefficient frequency dividing method using timer exclusive IC. | | | Wide time specification of 0.1 sec.¡24 hours. | | | On output part, power relay of high reliability is applied. | | | Definite operating state is expressed by pliot lamp of power on & time up lamp. | | | | | | | | | | Item | Performance | Repetition error | ±0.5% | Set error | below ±5% | Mechanical lifetime | above 5,000,000 times | Allowable voltage variagion range | rating voltage ± 10% | Voltage error | below ± 0.5% | Ambient temperature | -5 ~ +40 ℃ | Temperature error | below ± 2% | Ambient humidity | 45 ~ 85% RH | Withstand voltage | Electric circuit earth | AC2,000V/min | Between each circuits | AC1,500V/min | Between contact gaps | AC1,000V/min | Insulation resistance | above 100 ㏁ (DC500V. Meg) | Withstand vibration | 16.7Hz double amplitude 4.0mm | Withstand impact | 30G | Weight | about 150g | | | | | | | Type | Time spec. | Operating voltage | Note | Exposed type (for socket attachment) | Max.scale | Min.scale | Control time range | YSLT-03S | 3 sec | 0.05 sec | 0.1 sec ~ 3 sec | For AC110V/220V DC 24V DC 110VD C 125V | | YSLT-06S | 6 sec | 0.25 sec | 0.2 sec ~ 6 sec | YSLT-12S | 12 sec | 0.5 sec | 0.2 sec ~ 12 sec | YSLT-30S | 30 sec | 1 sec | 0.5 sec ~ 30 sec | YSLT-60S | 60 sec | 2.5 sec | 0.5 sec ~ 60 sec | YSLT-03M | 3 min | 3 sec | 1 sec ~ 180 sec | YSLT-06M | 6 min | 6 sec | 2.5 sec ~ 6 min | YSLT-12M | 12 min | 30 sec | 12 sec ~ 12 min | YSLT-30M | 30 min | 60 sec | 30 sec ~ 30 min | YSLT-60M | 60 min | 2.5 min | 30 sec ~ 60 min | YSLT-03H | 3 Hr | 6 min | 3 min ~ 3 Hr | YSLT-06H | 6 Hr | 15 min | 10 min ~ 6 Hr | YSLT-12H | 12 Hr | 30 min | 10 min ~ 12 Hr | YSLT-24H | 24 Hr | 60 min | 30 min ~ 24 Hr | | | | | | | | | | Type | Connection diagram | Operating pattern | YSLT (AC 110V/ 220V free) | | | YSLT (AC 110V or 220V free) | | | YSOT | | | | |
| | | | |