| | | · | HICAM(Hyundai Intelligent Communication and Measuring Device) integrated as many as 14 analog meters(voltmeter, ammeter, power meter, and so on) into one unit by a digital technology of HHI.
| · | 1) High measuring accuracy 2) Wide current, voltage input range . CT input: 0 - 80A . PT input: 48 - 380V 3) Many measuring points. Integration of as many as 14 analog meters 4) Various display and compact design . Communication address . Voltage display FND . Current display FND . Power display FND . Load percentage with bar graph. Size: 192(W) x 144(H) x 173(D) 5) Maximum load management function 6) Convenient configuration of power monitoring system . Industrial standardized protocol (ModBus, CAN 2.0) . Hyundai protocol(HD-BUS) . Optic fiber communication (option) 7) Pulse output function for active, reactive power metering 8) EMC test authorization of official institute . KTI (Korea Technology Institute) | | | | | Description | Specification | Rating | Current | 1A or 5A, Burden : 0.1VA/Phase | Voltage | 110V or 190V, Burdon : 0.1VA/Phase | Frequency | 50Hz or 60Hz | Accuracy | Meter | ±0.5% ~ ±2% | Temperature | Operation Guarantee | -10℃~55℃ | Storage Guarantee | -25℃~70℃ | Insulation | Between Circuit - Ground | 100㏁ | Between Circuit - Circuir | 100㏁ | Between Output Relay | 100㏁ | Dielectric Withstand | Power-Frequency Withstand | AC 60Hz 2000V/1minute | Lightning Impulse Withstand | 1.2/50㎲ 5kV | Overload Withstand | Current Circuit | Rated current × 6: 3 hours Rated current × 20 :1 second | Voltage Circuit | Rated voltage × 3 : 3 hours | Control Power | Rated voltage × 1.3 : 3 hours | Control Power Supply | AC/DC 85 ~ 265V, 50/60Hz | Connection Method | 3Phase 3wires, 3Phase 4wires | Communication Port | RS-485 | Protocol | HD-BUS/Modbus/Can 2.0B | Applicable Stamdard | KEMC 1110, IEC 1036 | Weight | 1.5Kg | Dimension | W202.5×H156×D156 | Measuring Measuring | Display | Accuracy | Remarks | Voltage(V) | 0 ~ 999,999V | ±0.5% | Line to line | Current(A) | 0 ~ 99,999.9A | ±0.5% | | Active Power(W) | 0 ~ 99,999.9kW | ±1.0% | Reactive Power(Var) | 0 ~ 99,999.9kvar | ±1.0% | Active Energy(Wh) | 0 ~ 99,999,999kWh | ±2.0% | Reactive Power(Varh) | 0 ~ 99,999,999kVarh | ±2.0% | Power Factor(PF) | LEAD/LAG 0 ~ 99% | ±1.0% | Frequency(Hz) | 45 ~ 65Hz | ±0.01Hz | Reverse Power | 0 ~ 99,999kW | ±2.0% | Reverse Active Power | 0 ~ 99,999,999kWh | ±2.0% | | · | Monitoring and control System monitoring Data acquisition On/off control Demand control Sequence control | · | Alarm management System alarm Event alarm SOE alarm | · | Trend Real time trend Historical trend | · | Report configulator Alarm report Daily/ weekly/ monthly/ yearly Trent report | · | l Data back up | · | l Multi tasking & others | | | |