This product is manufactured to product site
instruments and precision instruments from
threatened disaster factor such as surge,
high-voltage noise and lightening applied to
the signal line signal transmitting lines of various
magnetic field instruments.
MODEL & SPECIFICATION CODE
MODEL : MAR-24
Discharge voltage
FEATURES
Small size(mm) : 99(H), 25(W), 61(D).
Case & color : black ABS plastic case.
Weight : about 80g.
INSTALLATION
Operating temperature : -5~+55'C
Operating humidity : 90%RHmax.(non condensing)
Mounting : channel mount (rail type)
This product is manufactured to product site
instruments and precision instruments from
threatened disaster factor such as surge,
high-voltage noise and lightening applied to
the signal line signal transmitting lines of various
magnetic field instruments.
between lines : 30V or more
Max. surge voltage
Response time : 0.1microseconds or less
Discharge current : 10 kA (8X20 microseconds)
Max. load current : 100mA
Internal series resistance : Approx. 20ohm
Permissible leakage current
Capacity between lines : 1㎌
Max. line voltage : 30V
between line & GND : 500V maximum
between lines : 40V maximum
between lines : 5㎂ or less (at 30V DC)
between line & GND : 5㎂ or less (at 140V DC)