This production be fabricated for the purpose of
protection of the field instruments and /or the fine
measuring equipmints from the dangerous cause
like surge, noise of high voltage and thunderbolt
which can be applied to the power transmission
line of instrumentation equipments.
MODEL & SPECIFICATION CODE
MODEL : MAR-100/200
Discharge voltage
FEATURES
Small size(mm) : 99(H), 25(W), 61(D).
Case & color : black ABS plastic case.
Weight : about 80g.
INSTALLATION
Operating temperature : -5~+55'C
Operating humidity : 90%RHmax.(non condensing)
Mounting : channel mount (rail type)
This production be fabricated for the purpose of
protection of the field instruments and /or the fine
measuring equipmints from the dangerous cause
like surge, noise of high voltage and thunderbolt
which can be applied to the power transmission
line of instrumentation equipments.
between lines : 190V / 410V or more (peak)
Max. surge voltage
Response time : 0.1microseconds or less
Discharge current : 10KA (8X20 microseconds)
Max. load current : 2.0A
Internal series resistance : approx. 0.4ohm
Promissible Leakage Current
Capacity between lines : 1㎌
Max. line voltage : 120V AC / 170V DC(MAR-100)
between line & GND : 410V or more (peak)
between lines : 400V / 800V
between lines : 0.1mA or less (at 150V DC)
between line & GND : 0.1mA or less (at 300V DC)
STANDARD (AC/DC POWER LINE USE) ARRESTER
CONNECTION DIAGRAM
between line & GND : 800V
POWER
SOURCE
CONTROL ROOM
EQUIPMENT
SIDE
EQUIPMENT
SIDCABLE SIDE E
RELAY,
COIL
R
FIELD
Max. line voltage : 250V AC / 350V DC(MAR-200)