MR-RTD熱電阻溫度變換器RTD temperature converter (1ch)
This is a converter to convert to DC signal from the RTD
temperature sensor.
This is equipped with a linear type of compensation
circuit and compensates for non-linear error of the sensor,
and enables perfect signal conversion not affected by
withstand insulation voltage, transfer speed and noise,
etc by adopting precision isolation circuits.
FEATURES
Small size(mm) : 83(H), 51(W), 102(D).
Isolation : input to output to power supply.
Power supply : AC or DC supply.
Wiring : terminal socket wiring.
Case & color : black ABS plastic case.
Weight : 400g.
INPUT SIGNAL SPECIFICATION
OUTPUT SIGNAL SPECIFICATION
Output voltage signal : 12VDC max.
Output voltage impedance : 2Kohm min.
Output voltage noise : 10mV p-p max.
Output current signal : 30mADC max.
Output load resistance : 750ohm max.
Output current noise(250ohm load) : 10mV p-p.
GENERAL SPECIFICATION'S
Operating ambient temperature : 0 - 50'C.
Non operating ambient temperature : -20 ~ 80'C.
Temperature coefficient : 0.015%/'C.
Operating ambient humidity : 90% RH max.(non condensing)
Insulation resistance : greater than 100Mohm with 500VDC.
Dielectric strength : 1500VAC @ 1minute (input to output to power).
Adjustment range : 20% (zero & span) min.
Conversion accuracy : 0.2% max.
Response time : 0 - 90%(0.5sec).
Burnout circuit : upscale(standard).
Linearity : 0.2% max.
OUTPUT IMPEDANCE OUTPUT LOAD - R
0 - 1VDC
0 - 5VDC
1 - 5VDC
0 - 10VDC
0 - 1mA
0 - 20mA
1 - 5mA
4 - 20mA
> 1Kohm
> 2Kohm
> 2Kohm
> 4Kohm
< 15Kohm
< 750ohm
< 3Kohm
< 750ohm
Input type : 3wire type.
Input signal Pt50ohm or Pt100ohm
Input range : -200 ~ 600'C.
EXT Power : 1.5mA/5VDC.
This is a converter to convert to DC signal from the RTD
temperature sensor.
This is equipped with a linear type of compensation
circuit and compensates for non-linear error of the sensor,
and enables perfect signal conversion not affected by
withstand insulation voltage, transfer speed and noise,
etc by adopting precision isolation circuits.
MODEL & SPECIFICATION CODE
MODEL
INPUT SIGNAL
1 : 0 - 50'C
2 ; 0 - 100'C
3 : 0 - 150'C
4 : 0 - 200'C
5 : 0 - 300'C
6 : 0 - 400'C
7 : 0 - 500'C
8 : 0 - 600'C
9 : Specify temperature
OUTPUT SIGNAL
1 : 0 - 1mADC
2 : 0 - 20mADC
3 : 1 - 5mADC
4 : 4 - 20mADC
5 : 0 - 1VDC
6 : 0 - 5VDC
7 : 1 - 5VDC
8 : 0 - 10VDC
9 : Specify signal
POWER SUPPLY
1 : 110VAC/60Hz
2 : 220VAC/60Hz
3 : 12VDC/0.4ADC
4 : 24VDC/0.2ADC
MR - RTD
DISPLAY (OPTION)
Type : 3 digit FND
Display font : red super bright
Display function's : input or output or percent(%).
Display error : 1digit(LSB).
DISPLAY SIGNAL
1 : Input signal
2 : Output signal
3 : Percent(%)