Simple push-button calibration
Output 4-20mA, 20-4mA
Built-in temperature compensation
Compact size for easy mounting
+/-0.25% of full span accuracy
10-12 degree at -3dB beam angle
-Simple push-button calibration
-Output 4-20 mA ,20-4 mA
-Built-in temperature compensation
-Compact Size for Easy Mounting
-Food and Beverages
-Water/Wastewater
-Chemicals
-Oils
MECHANICAL
Conduit Entry : 1/2” NPT Hole
(PVC Conduit only)
Enclosure : PVC-94V0
Sensor : Standard - PVC,
Optional - S.S. or Teflon
Ingress Protection :NEMA 4X (IP65)
ENVIRONMENTAL
Temperature :Std. Unit - 40 to 140°F (-40 to 60°C)
Optional :Teflon Xducer.- 40 to 266°F(-40 to 130°C)
Pressure : - Std. Sensor 2 bar
- Optional Sensor 5 bar max.
(High Temp./Pressure Transducer)
Approvals : Intrinsic Pending
Installation Category : Class II
Accuracy : +/-0.1% of Max. span
(in lab using 4- 20mA current output)
+/-0.25% of max. range (typically in field)
Beam Angle : 10 -12 degree at –3dB
Loss of Echo :Hold 30 seconds, 22 or
3.5 mA (avg.)
Temperature Comp. : In transducer
Calibration : Push-button