OUTSIDE HUMIDITY TRANSMITTER(GOH-420) | | | "GOH" Outside Humidity Transmitters are intended for an electronic Humidity Transmitter to measure the outside Relative Humidity (RH) and convert the measurement into an electric signal. | | This unit can be used with all system equipments that can receive output signals 4 ~ 20mA DC of the detector. | | This Transmitter senses relative humidity by chargeable humidity sensing element which varies electrical capacity depending on circumstantial relative humidity Electronic sensing circuit varies signal into 4 ~ 20mA DC ( within 0 ~ 99% relative humidity ) Sensing Accuracy is ±3% within usable range of 20 ~ 90% Rh
| | SUPPLY VOLTAGE | : 24V AC/DC ±20%
| | FREQUENCY | : 50 or 60㎐ | SENSING ELEMENT | : Integrated Circuity | | POWER CONSUMPTION | : 0.35VA
| | SENSING RANGE | : 0 ~ 99% Rh | | ACCURACY | : 20°C at 20~90%Rh with in ±3%Rh
| | OUTPUT SIGNAL | : 4 ~ 20mA DC
| | SENSING TIME | : Apprx. 20 sec. | | | AMBIENT TEMPERATURE | : 1) On Operation : -35 ~ +80℃ 2) On Transportation & Storage : -25 ~ +65°C
| | AMBIENT HUMIDITY | : 1) On Operation : below 99%Rh 2) On Transportation & Storage : below 95% Rh | | WIRING | : wires, 1.0㎟ or Shield Cable
| | WEIGHT | : 0.06Kg
| | HOUSING | : plastic case
| PROTECTION CLASS | : IP 30 | | | The element must not be touched and should be protected from dust, water, spray and condensation. The sensor element must not be exposed to organic solvents, sylphid bearing materials. Select a location approx 1.5 meter above the floor. The sensor location should also be reasonably clean and free from damp and condensation. Fix with the bolts provided in pull box ( 50×100, 100×100 ) To avoid the conductive current the wires should be separated from power lines. Use the shield line when wiring | | OUTSIDE HUMIDITY TRANSMITTER(GOH-110) | | | "GOH" Outside Humidity Transmitters are intended for an electronic Humidity Transmitter to measure the outside Relative Humidity (RH) and convert the measurement into an electric signal. | | This unit can be used with all system equipments that can receive output signals 0 ~ 10V DC of the detector. | | This Transmitter senses relative humidity by chargeable humidity sensing element which varies electrical capacity depending on circumstantial relative humidity Electronic sensing circuit varies signal into 0 ~ 10V DC ( within 0 ~ 99% relative humidity ) Sensing Accuracy is ±3% within usable range of 20 ~ 90% Rh
| | SUPPLY VOLTAGE | : 24V AC/DC ±20%
| | FREQUENCY | : 50 or 60㎐ | SENSING ELEMENT | : Integrated Circuity | | POWER CONSUMPTION | : 0.35VA
| | SENSING RANGE | : 0 ~ 99% Rh | | ACCURACY | : 20°C at 20~90%Rh with in ±3%Rh
| | OUTPUT SIGNAL | : 0 ~ 10V DC( 0 ~ 1V DC) | | SENSING TIME | : Apprx. 20 sec | | | AMBIENT TEMPERATURE | : 1) On Operation : -35 ~ +80℃ 2) On Transportation & Storage : -25 ~ +65°C
| | AMBIENT HUMIDITY | : 1) On Operation : below 99%Rh 2) On Transportation & Storage : below 95% Rh | | WIRING | : wires, 1.0㎟ or Shield Cable
| | WEIGHT | : 0.06Kg
| | HOUSING | : plastic case
| PROTECTION CLASS | : IP 30 | | | The element must not be touched and should be protected from dust, water, spray and condensation. The sensor element must not be exposed to organic solvents, sylphid bearing materials. Select a location approx 1.5 meter above the floor. The sensor location should also be reasonably clean and free from damp and condensation. Fix with the bolts provided in pull box ( 50×100, 100×100 ) To avoid the conductive current the wires should be separated from power lines. Use the shield line when wiring | | OUTSIDE HUMIDITY TRANSMITTER(GOHO-420) | | | “GOHO” Outside Air Humidity Transmitter is intended for installing at the place of Heating, Ventilation facilities specially at the place needed to be pleasantness, and used for sensing humidity of outside air possible to be used by connecting with central control system.
| | SUPPLY VOLTAGE | : 15 ~ 30V DC | | OUTPUT SIGNAL | : 4 ~ 20 mA
| | POWER CONSUMPTION | : 0.35VA
| | SENSING RANGE | : 0 ~ 99% Rh | SENSING ELEMENT | : Integrated Circuity | | ACCURACY | : 20°C at 20~90%Rh with in ±3%Rh
| WIRING | : 2 Wire | | | SENSING TIME | : 1 minapprx.
| | | AMBIENT TEMPERATURE | : 1) On Operation : -30 ~ +70℃ 2) On Transportation & Storage : -20 ~ +50°C
| | AMBIENT HUMIDITY | : 1) On Operation : below 99%Rh 2) On Transportation & Storage : below 95% Rh | | | WEIGHT | : 0.08Kg
| | PROTECTION CLASS | : IP 30 | | | Install Location : Inside wall of good air ventilating place Prohibited Location : Inside corner, shelves, behind curtain or nearby reverse side of heat source. - Keep away from direct light and the end of wire tube of Sensor should be shielded to protect. any error from ventilating air coming through wire tube Calibration : As adjusted on delivery from factory, do not change voluntarily | | |