TP-26S 智能型壓力變送器SMART TYPE PRESSURE TRANSMITTER | | | : | -100,+100mmH2O ~ 1/1000kg/cm² | | | : | 4 ~ 20mA | | | : | LCD 16*2 ROW ALPHA NUMERIC CHARACTER | | | : | 12 ~ 36 VDC | | | : | -0.1%,0.1% | | | : | 2" PIPE MOUNTING, DIRECT | For these ranges the limits of the recommended span are not 7%-120%(of the nominal span) but 30%-120%. Therefore the model E span will be included between 0.18 and 0.72 bar, the model F span between 0.48 and 1.92 bar(to remain in the declared accuracy) GENERAL Series TP-26S transmitters, complete with diaphragm in SUS 316, measure relative pressure and level in measuring spans between 0.042 and 1000㎏/㎠. The pressure measuring element is a piezoresistive sensor. It is possible to choose between sensors to satisfy the process conditions. Span, Zero, Damping and other adjustments are made by a Hand-Held Terminal. This terminal can be connected in parallel to The transmitter at any point of the analog signal wire circuit. That means that the transmitter can be adjusted from the field or from the control room or an intermediate junction box. The sensor, protected from the process fluid by a diaphragm, generates a signal corresponding to the actual pressure and it is complete with a PTC thermistor which also transmits the temperature of the measuring cell to the electronic system. On the basis of these two values and of the configured parameters the electronic system generates a standard output signal (4 to 20mA, two wires system) and displays all the necessary data on the LED display. The operating parameters can be changed by means of the four pushbuttons that are below the LED display. Among the relevant characteristics of this microprocessor based transmitter, are the following: -wide rangeability for the measuring span (abt. 1 to 17) -automatic temperature compensation in the measuring cell REF. NOM. RANGE ㎏/㎠ min./max. ㎏/㎠ RANGE LIMITS min. (㎏/㎠) max. OVERPRESS. ㎏/㎠ E* 0 / 0.6 0.042-0.72 -0.6 / 0.6 6 F* 0 / 1.6 0.112-1.92 -1 / 1.6 10 G 0 / 4 0.28-4.8 -1 / 4 16 H 0 / 10 0.7-11 -1 / 10 30 K 0 / 25 1.75-26 -1 / 25 75 L 0 / 60 4.2-61 -1 / 60 100 M 0 / 160 11.2-161 -1 / 160 250 N 0 / 400 28-401 -1 / 400 600 O 0 / 1000 70-1100 -1 / Measuring range and span limits General Specifications Model TP-26S Smart Type Pressure Transmitter GT-321 12 - 99 (Intelligent Transmitter) FUNCTIONAL DATA With reference to the following, please note these definitions: Nominal range:(referred to the sensor mounted on the instrument) the pressure range (included between a minimum and a maximum values) to measure which the sensor has been designed. Nominal span: the pressure interval between the minimum and maximum values of the sensor nominal range. The span is a number. Measuring range: the pressure range between minimum and maximum for which the transmitter has been calibrated. Measuring span: the pressure interval between minimum and maximum values of the measuring range. Input scale initial value or zero input: minimum pressure value included in the measuring range. Input full scale value: maximum pressure value included in the measuring range. 1) Transmitter Parameters. The parameters that are available for display and setting are: Measuring Span: possibility to change by 0.05% steps from 120% to 7% of the nominal span. (see table). Zero Adjustment: by 0.1% steps from -9.9% to +9.9% of measuring span Span Adjustment: by 0.1% steps from -9.9% to +9.9% of measuring span Suppression/Elevation: by 0.05% steps of nominal span from 0 to 99% for elevation and from 0 to 93% for suppression Damping : adjustable by 1 sec steps from 0 to 15 sec. Reverse Output : obtained via software Measuring Units : for the measuring span display, one of the following units may be selected: mbar, bar-kPa, MPa-mmH20, mH2O,㎏/㎠. Physical Characteristics. Power supply : 12.35 - 30 Vdc with no load Supply voltage to permissible load relation: 0/250 Ohm for 17.35 Vdc 0/582.5 Ohm for 24 Vdc 0/882.5 Ohm for 30 Vdc Output signal : 4 -20mA, 2 wires Overpressure limits :see table Settling time : 150ms (at 27℃) ENVIRONMENT AND CONDITIONS Temperature Process fluid : -20 ~ + 90℃ Housing : -20 ~ + 80℃ Handling and storage : -20 ~ + 90℃ Relative Humidity : 0 ~ 99% R.H. LCD display reading : -10 ~ + 65℃ Performance Unless otherwise stated performance specifications are given at following conditions: ambient temperature = 20℃, silicone oil filling, max span. Unless otherwise stated, all errors are given as percentages of max span. Accuracy rating: it is assured within the following limits Non linearity : resettable with 0.1% accuracy Repeatability : ≤ 0.10% Hysteresis : ≤ 0.10% Dead band : negligible OPERATING INFLUENCES Thermal drift: It is referred to -10 ~ + 65℃ range. Zero: ±0.1%/10。K. Span: ±0.1%/10。K at nominal range. Power supply effect : Negligible between 12.35 and 30 V d.c. PHYSICAL SPECIFICATIONS Process wetted parts : SUS 316 SS Housing : die cast aluminium alloy AL UNI 4514 finished with epoxy resin (RAL 5014). Filling fluid : silicon oil. Nameplate : stainless steel, fixed on housing Calibration Standard: at nominal range, direct action, transmitter mode. Optional: at the conditions specified with the order. Environmental protection: the transmitter is dust and sand tight and protected against sea waves effects as defined by IEC IP 66. Suitable for tropical climate operation as defined in DIN 50.015. Process connections: See table 1 Electrical connections : two cable entries on electronic housing, 1/2" NPT and cable gland PG 13.5 for 7 to 12mm diameter cable. Terminal board : 2 terminals for signal wiring up to 1.5 mm (14 AWG). Connection for ground and cable shield. Mounting position : any position. Net weight : 1.4 Kg approx. Options Bracket: for 2 inch pipe mounting. Degreesing for oxygen service. EXPLOSION PROTECTION Classification. Type: intrinsic safety Ex ia IIC T6, T5, T4. Max Amb. temp.: 40℃ for T6, 55℃ for T5, 80℃ for T4. Power supply conditions : Condition A No-load voltage: ≤30 V d.c. Short circuit current: ≤120 mA. Max transferred power: 0.75 W. Condition B No-load voltage: ≤25.2 V d.c. Short circuit current: ≤152 mA. Max transferred power: 0.95 W. Note Explosion proof feature (Exd 〔ia〕 IIC T6) with the application of barrier |