Model | | 2L-LIC-D/P (Resistance Input) | | Input Voltage | | AC 220V (100V separate order) | | Contact Point Capacity | | CONTROL AC 220V 5A HI/LO AC 220V 3A | | Feature | | Resistance Input Method(0~300Ω) | | Function | | Indication , water supply/draining automation and alarm for high/low water level in various kind of tank | | Panel CUT | | 92×45 / 98×50×102 | | Material | | - HEAD - Nylon Fiber - FLOAT- P/P foaming - PIPE - SUS 304 | | | Model | | 2L-LIC-D/P (Current Input) | | Input Voltage | | AC 220V (100V separate order) | | Contact Point Capacity | | CONTROL AC 220V 5A HI/LO AC 220V 3A | | Feature | | Current Input (4~20mA) | | Function | | Indication , water supply/draining automation and alarm for high/low water level in various kind of tank | | Panel CUT | | 92×45 / 98×50×102 | | Material | | - HEAD - Nylon Fiber - FLOAT- P/P foaming - PIPE - SUS 304 | | | | | ▶ | 2L-LIC-D/P is the Digital Level Indicating Controller built in a Micom Chip, it can check the indicating value as setting High/Low level alarm and Auto Feeding/Drainage for various kinds of tanks as Digital Mode. It is the Resistance Input (0~300Ω) Type of level controller built in the function isolating a contact output in case of the line disconnecting or the abnormal condition of sensor. | ▶ | Composed easy to control and set-up, it is manufactured to operate strongly against the power noise or the induction of sensor line, etc. | | | | (Resistance Input) | Using power : AC 220V 60HZ 2W (Special order - 100V) | Contact Capacity : 5A MAX(LO-AL/HI-AL/Feeding. Drainage Contact) | Control Output : Contact of Feeding. Drainage, LO-AL, HI-AL, 4/20mA) | Input Signal : 0-300Ω Resistance(Indicating Meter Sensor & Parallel mode) | Error : ±0.5FS | Operating condition : 0~50℃ 0~80%RH | Outer dimension : 98×50×102(H×W×D) CUT/92×45 | Usage : Level indicating Controller for various kinds of Water tanks, Oil tank, etc Sensor is required to use with less than 80℃ (Separate order for more than 80℃) | | MODE | When pressing a Mode upon setting up, LED Lamp lights in order;LO-AL>START>STOP>HI-AL | Indicating Limit | 0%~120% (In case of more than 120%, 'hid' flickers) (0%~99%) | DN | Using to decrease the setting value in the position of LED Lamp required | hid | In case of line disconnecting, the abnormal condition of sensor or 99% setting is not exact, it flickers | UP | Using to increase the setting value in the position of LED Lamp required | Setting limit | 0%~120% (LO-AL/HI-AL/START/STOP) | ENT | After setting values in the setting position of each Mode, press an ENT. All are remembered. | Sensor Input | Voltage mode 0~1.5V (Indicating meter) by a Resistance Input(0~300Ω) | Reference | If not press an ENT for 5 sec., it returns to the original display position | With the first delivery, LO-AL(40%), START(60%), STOP(80%), HI-AL(90%) are set | When 'hid' flickers, the function of mode won't work. | | Reference | Indicating meter can be connected up to 3 units by Parallel Mode with a Sensor terminal (0~1.5V) | 4~20mA Output Terminal builds in a card (Option) when ordering. (Separate setting or insert is possible) | Set 99% numeric value as putting a sensor float in 99% position and adjusting 99% set in a unit. | | | | | | ▶ | 2L-LIC-D/P is the Digital Level Indicating Controller built in a Micom Chip, it can check the indicating value as setting High/Low level Alarm and Auto Feeding/Drainage for various kinds of tanks as Digital Mode. It is the Current Input (4-20MA) Type of Level Controller built in the function isolating contact output in case of line disconnecting, short or the abnormal condition of sensor. | ▶ | Composed easy to control and set-up, it is manufactured to operate strongly against the power noise or the induction of sensor line, etc | | | | (Current Input) | Using power : AC 220V 60HZ 2W (Special order - 100V) | Contact Capacity : 5A MAX(LO-AL/HI-AL/Feeding. Drainage Contact) | Control Output : Contact of Feeding. Drainage, LO-AL, HI-AL) | Input Signal : 4-20MA (Indicating Meter & Sensor Series mode) | Error : ±0.5FS | Operating condition : 0~50℃ 0~80%RH | Outer dimension : 98×50×102(H×W×D) CUT/92×45 | Usage : Level indicating Controller for various kinds of Water tanks, Oil tank, etc Sensor is required to use with less than 80℃ (Separate order for more than 80℃) | | | MODE | When pressing a Mode upon setting up, LED Lamp lights in order;LO-AL>START>STOP>HI-AL | Indicating Limit | -3% - 120% (In case of less than -3%, 'oPn' flickers, more than 120%, 'hid' flickers) (0%~99%) | DN | Using to decrease the setting value in the position of LED Lamp required | hid | In case of more than 120%(more than 20mA, or the abnormal of sensor), it flickers | oPn | It flickers in -3% (Less than 4mA or the abnormal of sensor). (When sensor isn't connected) | UP | Using to increase the setting value in the position of LED Lamp required | Setting limit | 0%~120% (LO-AL/HI-AL/START/STOP) | ENT | After setting values in the setting position of each Mode, press an ENT. All are remembered. | Sensor Input | Current mode (Indicating meter 4~20mA series mode) by Current Input(4~20mA) | Reference | If not press an ENT for 5 sec., it returns to the original display position | With the first delivery, LO-AL(40%), START(60%), STOP(80%), HI-AL(90%) are set | When 'hid' flickers, the function of mode won't work. | | Reference | Indicating meter for 4~20mA use should be connected with a sensor by Series Mode (Line Resistance 700ΩMAX) | | Regulate 0~99%, adjusting SPAN and ZERO inside of a Sensor Head | | | |
| ▶ | Fill the existence of pressure such as non-pressure tank, pressure tank(less than 5 kg) according to the classes of tanks and separate entry is required if temperature is high (more than 80℃). (Special order in case of more than 5K) | ▶ | There are two types; Flange and Screw type. In case of a Flange type, it should use with 3″(80Φ)4″(100Φ), In case of a Screw type, 2″(50Φ) socket should be welded to a tank. | ▶ | Separate order is required for special chemicals and high temperature use. (80℃ and more) | | Gear-type Sensor | Flexible Sensor | ◆ | As Gear-type sensor hasn't the height of ceiling, it is ordered and manufactured as a Gear-type when sensor isn't able to put in a tank. | ◆ | Refer to the Gear-Type in the tail of 35~36 page | ◆ | Temperature should be less than 80℃ only (Oil, Water, etc) | ◆ | Special order is required for the chemicals tank such Hydrochloric acid, Sulphuric acid | | [Attention!] Never use to a Pressure tank | | ◆ | As Flexible-type sensor hasn't the height of ceiling, it is ordered and manufactured as a Flexible-type when sensor isn't able to put in a tank. | ◆ | In the lower part of sensor, the stain weight is an one-touch fitting. Simple to put a hose in (50mm/m socket-type). | ◆ | When handling a sensor, Put a stain weight in first and continue to put with care while remaining a sensor as the original position. (Be careful not to be bent) | ◆ | When delivering, deliver as a fixed position to the handling frame (PVC Pipe) and Do not give an impulse or throw. (It can be the reason of damage) | ◆ | Temperature should be less than 80℃ only (Oil, Water, etc) | | [Attention!] Never use to a Pressure tank | | | | ■ Indicator/ Automatic water supply and drain/ Low water level Alarm for various water/oil tanks ■ 2 Line Parallel Method (Sensor and Indicator Meter) 4~20mA ※ Caution : Cannot use for oil, chemicals or steam tank (over 80℃) ※ Separate Order for High Temperature and Special Purpose. Name | LEVEL INDICATING CONTROLLER | Model | 2L-LIC-D/P | Input Voltage | AC 220V (100V separate order) | Contact Point Capacity | CONTROL AC 220V 5A HI/LO AC 220V 3A | Input | input current (4~20mA) | Function | Indication , water supply/draining automation and alarm for high/low water level in various kind of tank | Panel CUT | 92×45 / 98×50×102 | |