Name | 3 STAGE PUMP CONTROLLE | Model | 2L-3S2W | Input Voltage | AC 220V (100V separate order) | Contact Point Capacity | PUMP-1 ~ 3AC 22OV 5A HI/ALARM AC 220V 3A | Feature | 2 Line Method (Unit & Sensor) | Function | 3 stage pump controller and alarm for high water level | | ■ 3 Level Pump Controller, Alternating Controller, and High/Low water level alarm for various water / seawater / water-purifier tanks, drainage and waste water ■ Best for water purifier tank , draining and waste water ■ 2 Line Method, no need for +/- distinction. ※ Caution : Cannot use for oil, chemicals or steam tank (over 60℃) | | Model |
| 2L-3S2W |
| Input Voltage |
| AC 220V (100V separate order) |
| Contact Point Capacity |
| PUMP- 1 ~ 3 AC 22OV 5A HI/AL AC 220V 3A |
| Feature |
| 2 Line Method (Unit & Sensor) |
| Function |
| 3 stage pump controller and alarm for high water level |
| Material |
| HEAD - P/P FLOAT- P/P foaming ROPE - P/P WEIGHT - STEEL/SUS304 | | | |
| ▶ | 2L-3S2W is a Float type level Controller, which, by combining sensor and unit with two line, has its capacity of controlling water supply and draining as well as alarming high/low level of water. This new type level controller can save personnel expense, cost for wires and can solve problems of distinguishing various types of complex component of lines, which doesn't require +/- distinction even between unit & sensor. | ▶ | The first company in Korea to install 3 gear controller/ alternating controller/ high water level alarm in the unit | |
| ▶ | Waste water. | ▶ | Rusty areas such as water-purifier tank. | ▶ | Water tank and waste are | ▶ | Can use up to 3 pumps for multi-controllers and alternating controller | | | | | |
| ▣ | 2"(5mm) socket needs to be welded in the right place and for use of French type, use 65 or more. | ▣ | Installation place needs to be free of hood or obstacles with in a radius of 30cm X 30cm. If there is 부래 nearby hood, it may not work properly because of it. | ▣ | 3. When tieing rope to the sinker, please bind fast. | | ※ 2" socket type is the factory default. ( Separate order for French Type) | |
| ▣ | Connect 5 ball as directed to the connector by the color (White to white, black to black) - Parallel Connection. | ▣ | Please be noted that the lead S/S of 부래 moves a little bit higher from the level. | ▣ | As each resistance is connected each other withing the controller, please distinguish 부래 when use. | ▣ | The controller cannot be used for general purpose. | | | | | ▶ | Measure output when the unit is ON. 1. PUMP-1 PUMP-2 PUMP-3 2. PUMP-2 PUMP-1 PUMP-3 3. PUMP-3 PUMP-2 PUMP-1 | ▶ | When P1, P2 and P3 Stop Ball switches from OFF to ON, the above (1)~(3) sequence will alternate. | | ▶ | When using sequential movement instead of alternate controller, it will process easily. | ▶ | To use PUMP-3 movement & high alarm at the same time, use 5 ball instead of 4. | | | |
| H1-ALARM ball P3-START ball P2-START ball P1-START ball STOP ball | ------- ------- ------- ------- ------- | 0Ω 1㏀ 2㏀ 3.3㏀ 5.6㏀ | | | |