Kiepe VG 033/5 感應傳感器
Kiepe Typ.MAS 001 Nr.91.050688.001 感應傳感器
Kiepe VG 03/5 感應傳感器
Kiepe 96040610110 DG10 感應傳感器
Kiesel stator of SP10 Nr2979 泵用零件(定子)
Kinetronic Typ: DLG 401-3 編碼器
Kinetronic Typ: PWG 79 S 120 - 0010 - A02,Old:PWG 200-4-Q 編碼器
Kinetronic Typ: PWG 79 S 350 - 0010 - A01,Old:PWG 400-Q 編碼器
Kinetronic PWG 79 S 120 - 0010 - A02,Old:PWG 200-Q
Kinetronic PWG 79 S 350 - 0010 - A01, Old:PWG 400-Q Kiepe VG 033/5 感應傳感器
KIRA Leuchten GmbH KE-EX 6836/24-00-0 熒光燈管
KIRCHNER+TOCHTER GKLA-000007;08603-001-10 流量計
kissing 26.08.07 自動控制器
kissing PSI/011/204/905 感應傳感器
KISSLING 65.B12.106 D 43 GE250-M 感應傳感器
KISSLING L408.2116.25 10-30V 感應傳感器
KISSLING 54 810 101 R 53 感應傳感器
KISSLING LA12XLMP25 KLD M3 感應傳感器
KISSLING PS1 091 302 感應傳感器
KISSLING MND1 041 150 感應傳感器
KISSLING MDH1071221 250VAC 4A 感應傳感器
KISSLING PS1011 204905 感應傳感器
KISSLING PS8 031 306 15A 250VAC 感應傳感器
KISSLING Mini-switch MDH1 081 221 感應傳感器
KISSLING 541 102 930 感應傳感器Kiepe VG 033/5 感應傳感器
KISSLING Elektrotechnik GmbH GWF2K12-S-913 感應傳感器
KISSLING Elektrotechnik GmbH 65.F16-701 R72-906-M 壓力變送器
KISSLING Elektrotechnik GmbH MIKROSCHALTER PS8 031 207 PS8 031 207 S04/1904/5045 感應傳感器
kistler 2151B15052001 負荷傳感器
kistler 4733AWDY1X20000 DMF-P A400 力檢測儀
kistler 4737AWY1X200S1 可編程控制器
kistler 5855B22 自動控制器
CLKnotes CLICK PLC Units
C0-00DD1-D CLICK Basic PLC, 8 KB user memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 5 - 27 VDC, sinking. Removable terminal block included.
C0-00DD2-D CLICK Basic PLC, 8 KB user memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 24 VDC, sourcing. Removable terminal block included.
C0-00DR-D CLICK Basic PLC, 8 KB user memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included. Kiepe VG 033/5 感應傳感器
C0-00AR-D CLICK Basic PLC, 8 KB user memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 120 VAC, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included.
C0-01DD1-D CLICK Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 5 - 27 VDC, sinking. Removable terminal block included. Requires CLICK programming software v1.20 or later and CLICK CPU firmware v1.20 or later.
C0-01DD2-D CLICK Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 24 VDC, sourcing. Removable terminal block included. Requires CLICK programming software v1.20 or later and CLICK CPU firmware v1.20 or later.
C0-01DR-D CLICK Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included. Requires CLICK programming software v1.20 or later and CLICK CPU firmware v1.20 or later.
C0-01AR-D CLICK Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 120 VAC, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included. Requires CLICK programming software v1.20 or later and CLICK CPU firmware v1.20 or later.
C0-02DD1-D CLICK Analog PLC, 8 KB user memory, real time clock/calendar, battery backup, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, Discrete I/O: 4-point input, 24 VDC, sinking/sourcing, 4-point output, 5 - 27 VDC, sinking, Analog I/O: 2-channel input, input current signal range(s) of 4 - 20 mA, input voltage signal range(s) of 0 - 5 VDC, 2-channel output, output current signal range(s) of 4 - 20 mA, output voltage signal range(s) of 0 - 5 VDC, external 24 VDC required. Removable terminal block included. Requires CLICK programming software v1.12 or later and CLICK CPU firmware v1.10 or later.
C0-02DD2-D CLICK Analog PLC, 8 KB user memory, real time clock/calendar, battery backup, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, Discrete I/O: 4-point input, 24 VDC, sinking/sourcing, 4-point output, 24 VDC, sourcing, Analog I/O: 2-channel input, input current signal range(s) of 4 - 20 mA, input voltage signal range(s) of 0 - 5 VDC, 2-channel output, output current signal range(s) of 4 - 20 mA, output voltage signal range(s) of 0 - 5 VDC, external 24 VDC required. Removable terminal block included. Requires CLICK programming software v1.12 or later and CLICK CPU firmware v1.10 or later.
C0-02DR-D CLICK Analog PLC, 8 KB user memory, real time clock/calendar, battery backup, RS-232 (RJ12) port with programming and monitoring protocol(s) at up to 115.2k baud, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, Discrete I/O: 4-point input, 24 VDC, sinking/sourcing, 4-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC, Analog I/O: 2-channel input, input current signal range(s) of 4 - 20 mA, input voltage signal range(s) of 0 - 5 VDC, 2-channel output, output current signal range(s) of 4 - 20 mA, output voltage signal range(s) of 0 - 5 VDC, external 24 VDC required. Removable terminal block included. Requires CLICK programming software v1.12 or later and CLICK CPU firmware v1.10 or later.
C0-10DD1E-D CLICK Ethernet Basic PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 5 - 27 VDC, sinking. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
C0-10DD2E-D CLICK Ethernet Basic PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 24 VDC, sourcing. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
C0-10DRE-D CLICK Ethernet Basic PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
C0-10ARE-D CLICK Ethernet Basic PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 120 VAC, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
C0-11DD1E-D CLICK Ethernet Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 5 - 27 VDC, sinking. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
C0-11DD2E-D CLICK Ethernet Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, 24 VDC, sourcing. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
C0-11DRE-D CLICK Ethernet Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 24 VDC, sinking/sourcing, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
C0-11ARE-D CLICK Ethernet Standard PLC, 8 KB user memory, real time clock/calendar, retentive memory, Ethernet (RJ45) port with Modbus TCP, programming and monitoring protocol(s) at 10/100 Mbps, RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, 8-point input, 120 VAC, 6-point output, Form A (SPST) relay(s), 6 - 240 VAC / 6 - 27 VDC. Removable terminal block included. Requires CLICK programming software v2.00 or later and CLICK CPU firmware v2.00 or later.
CLKdiscnotes CLICK Discrete DC I/O Option Modules
C0-08ND3 CLICK discrete input module, 8-point, 12 - 24 VDC, sinking/sourcing, 2 isolated common(s), 4 point(s) per common. Removable terminal block included.
C0-08ND3-1 CLICK discrete input module, 8-point, 3.3 - 5 VDC, sinking/sourcing, 2 isolated common(s), 4 point(s) per common. Removable terminal block included.
C0-16ND3 CLICK discrete input module, 16-point, 24 VDC, sinking/sourcing, 4 isolated common(s), 4 point(s) per common. Removable terminal block included.
C0-08TD1 CLICK discrete output module, 8-point, 3.3 - 27 VDC, 2 isolated common(s), 0.3A / point, sinking. Removable terminal block included.
C0-08TD2 CLICK discrete output module, 8-point, 12 - 24 VDC, 1 isolated common(s), 0.3A / point, sourcing. Removable terminal block included.
C0-16TD1 CLICK discrete output module, 16-point, 5 - 27 VDC, 2 isolated common(s), 0.1A / point, sinking. Removable terminal block included.
C0-16TD2 CLICK discrete output module, 16-point, 12 - 24 VDC, 2 isolated common(s), 0.1A / point, sourcing. Removable terminal block included.
C0-08CDR CLICK discrete combo module, 4-point input, 12 - 24 VDC, sinking/sourcing, 4-point output, 6 - 240 VAC / 6 - 27 VDC, 0.1A / point, Form A (SPST) relay(s). Removable terminal block included.
C0-16CDD1 CLICK discrete combo module, 8-point input, 24 VDC, sinking/sourcing, 8-point output, 5 - 27 VDC, 0.1A / point, sinking. Removable terminal block included.
C0-16CDD2 CLICK discrete combo module, 8-point input, 24 VDC, sinking/sourcing, 8-point output, 12 - 24 VDC, 0.1A / point, sourcing. Removable terminal block included.
C0-08NA CLICK discrete input module, 8-point, 100 - 120 VAC, 2 isolated common(s), 4 point(s) per common. Removable terminal block included.
C0-08NE3 CLICK discrete input module, 8-point, 24 VAC/DC, sinking/sourcing, 2 isolated common(s), 4 point(s) per common. Removable terminal block included.
C0-16NE3 CLICK discrete input module, 16-point, 24 VAC/DC, sinking/sourcing, 4 isolated common(s), 4 point(s) per common. Removable terminal block included.
C0-08TA CLICK discrete output module, 8-point, 17 - 240 VAC, 2 isolated common(s), 0.3A / point. Removable terminal block included.
C0-04TRS CLICK relay output module, 4-point, 6 - 240 VAC/6 - 27 VDC, Form C (SPDT) relay(s), 4 common(s), isolated, 1 point(s) per common, 7A / point. Removable terminal block included.
C0-08TR CLICK relay output module, 8-point, 6 - 240 VAC/6 - 27 VDC, Form A (SPST) relay(s), 2 isolated common(s), 4 point(s) per common, 1A / point. Removable terminal block included.
CLICK Analog I/O Option Modules
C0-04AD-1 CLICK analog input module, 4-channel, 13-bit resolution, input current signal range(s) of 0 - 20 mA, external 24 VDC required. Removable terminal block included.
C0-04AD-2 CLICK analog input module, 4-channel, 13-bit resolution, input voltage signal range(s) of 0 - 10 VDC, external 24 VDC required. Removable terminal block included.
C0-04DA-1 CLICK analog output module, 4-channel, 12-bit resolution, output current signal range(s) of 4 - 20 mA, external 24 VDC required. Removable terminal block included.
C0-04DA-2 CLICK analog output module, 4-channel, 12-bit resolution, output voltage signal range(s) of 0 - 10 VDC, external 24 VDC required. Removable terminal block included.
C0-4AD2DA-1 CLICK analog combo module, 4-channel input, 13-bit input resolution, input current signal range(s) of 0 - 20 mA, 2-channel output, 12-bit output resolution, output current signal range(s) of 4 - 20 mA, external 24 VDC required. Removable terminal block included.
C0-4AD2DA-2 CLICK analog combo module, 4-channel input, 13-bit input resolution, input voltage signal range(s) of 0 - 10 VDC, 2-channel output, 12-bit output resolution, output voltage signal range(s) of 0 - 10 VDC, external 24 VDC required. Removable terminal block included.
C0-04RTD CLICK temperature input module, 4-channel, 16-bit resolution, input RTD type(s): Cu10, Cu25, JPt100, Ni120, Pt100 and Pt1000, input resistance signal range(s) of 0 - 3125 Ohms, 0 - 1562.5 Ohms, 0 - 781.25 Ohms, 0 - 390.625 Ohms and 0 - 195.3125 Ohms. Removable terminal block included.
C0-04THM CLICK temperature input module, 4-channel, 16-bit resolution, input thermocouple type(s): B, C, E, J, K, N, R, S, T, input voltage signal range(s) of +/- 156 mV, +/- 39.0625 mV, +/- 78.125 mV, 0 - 1.25V, 0 - 156 mV, 0 - 39.0625 mV. Removable terminal block included.
CLKpsnotes CLICK Power Supplies
C0-00AC CLICK power supply, 100 - 240 VAC input, 24 VDC output, 0.5A continuous.
C0-01AC CLICK power supply, 100 - 240 VAC input, 24 VDC output, 1.3A continuous.
CLKprognotes CLICK Programming
C0-PGMSW CLICK PLC Windows PC programming and documentation software for the CLICK C0 series PLCs, CD-ROM includes software and manual in PDF format.
C0-USER-M CLICK user manual. Covers all CLICK CPU and I/O module installation and wiring, specifications, error codes and troubleshooting guide. Order manual separay from hardware.
CLKsparenotes CLICK Spare Parts and Accessories
C0-3TB CLICK terminal block, replacement, 3-pole. Package of 2. For use with the 3-wire RS485 communications port on CLICK Standard and Analog PLCs.
C0-4TB CLICK terminal block, replacement, 4-pole. Package of 2. For use with the 24 VDC supply power terminals on CLICK PLCs.
C0-8TB CLICK terminal block, replacement, 11-pole. Package of 2. For use with CLICK 8-point I/O modules.
C0-16TB CLICK terminal block, replacement, 20-pole. Package of 2. For use with CLICK 16-point I/O modules and CLICK PLCs built-in I/O.
Do-more H2 Series PLC CPUs
H2-DM1 Do-more H2 series PLC CPU module, DL205 form factor, 192k words total (64k words ladder (flash memory), 128k words user data memory (SRAM with battery backup)). Ladder programming, real time clock/calendar, two built-in communications ports: (1) RS-232 port supports programming, K-sequence slave, MODBUS RTU master/slave and ASCII IN/OUT; (1) USB port supports programming. Supports bumpless run-time editing and 2000 PID loops. Battery included. Requires Do-more Designer programming software (free download online). User manual H2-DM-M available as a free download, or purchase hard copy separay.
H2-DM1E Do-more H2 series PLC CPU module, 192k words total (64k words ladder (flash memory), 128k words user data memory (SRAM with battery backup)). Ladder programming, real time clock/calendar, three built-in communications ports: (1) RS-232 port supports programming, K-sequence slave, MODBUS RTU master/slave and ASCII IN/OUT; (1) USB port supports programming; (1) Ethernet port supports programming, Do-more Ethernet I/O, TCP/IP, UDP/IP and Modbus/TCP. Supports bumpless run-time editing and 2000 PID loops. Battery included. Requires Do-more Designer programming software (free download online). User manual H2-DM-M available as a free download, or purchase hard copy separay.?
Do-more H2 Series PLC Starter Kits
H2-DM1-START Do-more H2 series PLC starter kit, includes (1) H2-DM1 CPU, (1) 3-slot base D2-03B-1, (1) input simulator F2-08SIM, (1) output module D2-08TR, (1) USB programming cable USB-CBL-AB6, (1) Do-more PLC H2 Series User Manual H2-DM-M and (1) software CD-ROM. No substitution of individual part numbers.
H2-DM1E-START Do-more H2 series PLC starter kit with embedded Ethernet, includes (1) H2-DM1E CPU, (1) 3-slot base D2-03B-1, (1) input simulator F2-08SIM, (1) output module D2-08TR, (1) USB programming cable USB-CBL-AB6, (1) Do-more PLC H2 Series User Manual H2-DM-M and (1) software CD-ROM. No substitution of individual part numbers.
Do-more TH1 Series PLC CPUs
T1H-DM1 Do-more T1H series PLC CPU module, Terminator I/O form factor, 192k words total (64k words ladder (flash memory), 128k words user data memory (SRAM with battery backup)). Ladder programming, real time clock/calendar, two built-in communications ports: (1) RS-232 port supports programming, K-sequence slave, MODBUS RTU master/slave and ASCII IN/OUT; (1) USB port supports programming. Supports bumpless run-time editing and 2000 PID loops. Battery included. Requires Do-more Designer programming software (free download online). User manual T1H-DM-M available as a free download, or purchase hard copy separay.
T1H-DM1E Do-more T1H series PLC CPU module, Terminator I/O form factor, 192k words total (64k words ladder (flash memory), 128k words user data memory (SRAM with battery backup)). Ladder programming, real time clock/calendar, three built-in communications ports: (1) RS-232 port supports programming, K-sequence slave, MODBUS RTU master/slave and ASCII IN/OUT; (1) USB port supports programming; (1) Ethernet port supports programming, TCP/IP, UDP/IP and Modbus/TCP. Supports bumpless run-time editing and 2000 PID loops. Battery included. Requires Do-more Designer programming software (free download online). User manual T1H-DM-M available as a free download, or purchase hard copy separay.
Do-more PLC Programming Software and Manuals
DM-PGMSW Do-more Designer Windows PC programming and documentation software for the Do-more PLC series. Windows XP (Pro or Home, 32-bit), Windows Vista (Home, Basic or Premium, 32 or 64-bit) and Windows 7 (Home, Professional, Ultimate, 32 or 64-bit) supported. Order programming cable separay. Also available for free download online at www.aboutplcs。。com.
H2-DM-M Do-more H2 series PLC user manual, covers Do-more H2 series CPUs, bases, discrete I/O, analog I/O and inligent modules. Free download online or order hard copy separay.
T1H-DM-M Do-more T1H series PLC user manual, covers Do-more T1H series CPUs, bases, discrete I/O, analog I/O and inligent modules. Free download online or order hard copy separay.
DL05notes DL05 PLC Units
D0-05AA DL05 CPU, 8 AC in / 6 AC out, requires external 110-220 VAC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C communications port. Inputs: 8 AC inputs, 90-120 VAC, 2 isolated commons. Outputs: 6 AC outputs, 17-240 VAC, 0.5A/point max., 2 isolated commons. One option slot available for I/O or communication module.
D0-05AD "DL05 CPU, 8 AC in / 6 DC out, requires external 110-220 VAC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C communications port. Inputs: 8 AC inputs, 90-120 VAC, 2 isolated commons. Outputs: 6 DC outputs, 6-27 VDC current sinking, 1.0A/point max, 1 common. 2 outputs are configurable for independent CW/CCW pulse train output or step and direction pulse output up to 7kHz (0.5A/point). One option slot available for I/O or communication module.
"
D0-05AR DL05 CPU, 8 AC in / 6 relay out, requires external 110-220 VAC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C communications port. Inputs: 8 AC inputs, 90-120 VAC, 2 isolated commons. Outputs: 6 relay outputs, 6-27 VDC, 6-240 VAC, 2A/point max., 2 isolated commons. One option slot available for I/O or communication module.
D0-05DA DL05 CPU, 8 DC in / 6 AC out, requires external 110-220 VAC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C communications port. Inputs: 8 DC inputs, 12-24 VDC current sinking/sourcing, 2 isolated commons. First 3 inputs are configurable in one of several high-speed I/O features such as 5kHz counter input, pulse catch input, or interrupt input. Outputs: 6 AC outputs, 17-240 VAC, 0.5A/point max., 2 isolated commons. One option slot available for I/O or communication module.
D0-05DD DL05 CPU, 8 DC in / 6 DC out, requires external 110-220 VAC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C communications port. Inputs: 8 DC inputs, 12-24 VDC current sinking/sourcing, 2 isolated commons. First 3 inputs are configurable in one of several high-speed I/O features such as 5kHz counter input, pulse catch input, or interrupt input (not available when using pulse output). Outputs: 6 DC outputs, 6-27 VDC current sinking, 1.0A/point max., 1 common. 2 outputs are configurable for independent CW/CCW pulse train output or step and direction pulse output up to 7kHz (0.5A/point) (not available when using high-speed inputs). One option slot available for I/O or communication module.
D0-05DR DL05 CPU, 8 DC in / 6 Relay out, requires external 110-220 VAC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C communications port. Inputs: 8 DC inputs, 12-24 VDC current sinking/sourcing, 2 isolated commons. First 3 inputs are configurable in one of several high-speed I/O features such as 5kHz counter input, pulse catch input, or interrupt input. Outputs: 6 relay outputs, 6-27 VDC, 6-240 VAC, 2A/point max., 2 isolated commons. One option slot available for I/O or communication module.
D0-05DD-D DL05 CPU, 8 DC in / 6 DC out, requires external 12-24 VDC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C comm. port. Inputs: 8 DC inputs, 12-24 VDC current sinking/sourcing, 2 isolated commons. First 3 inputs configurable in one of several high-speed I/O features such as 5kHz counter input, pulse catch input, or interrupt input (not available when using pulse output). Outputs: 6 DC outputs, 6-27 VDC current sinking, 1.0A/point max., 1 common. 2 outputs configurable for independent CW/CCW pulse train output or step and direction pulse output up to 7kHz (0.5A/point) (not available when using high-speed inputs). One option slot available for option module.
D0-05DR-D DL05 CPU, 8 DC in / 6 Relay out, requires external 12-24 VDC power. 6k words total (2048 words ladder - flash, 4096 words V-memory), RLL/RLLPLUS programming, built-in RS-232C programming port and additional RS-232C communications port. Inputs: 8 DC inputs, 12-24 VDC current sinking/sourcing, 2 isolated commons. First 3 inputs are configurable in one of several high-speed I/O features such as 5kHz counter input, pulse catch input, or interrupt input. Outputs: 6 Relay outputs, 6-27 VDC, 6-240 VAC, 2A/point max., 2 isolated commons. One option slot available for I/O or communication module.
D0-USER-M All DL05 CPUs are covered in the DL05 User Manual. Order manual separay.
DL05specnotes DL05 Specialty Modules
D0-01MC Removable memory cartridge with 32k battery backed CMOS RAM, external upload/download controls, real time clock/calendar. Compatible only with DL05 CPU units. Battery included.
DL05sparenotes DL05 Spare Parts and Accessories
D0-MC-BAT Replacement battery for Do-more H2 and T1H series CPU modules, and D0-01MC optional memory cartridge for DL05 PLCs
D0-ACC-1 DL05 accessory pack includes one each of the I/O terminal block, I/O terminal block cover, and option slot cover.
DL06notes DL06 PLC Units
D0-06AA DL06 CPU, 20 AC in / 16 AC out, requires external 110-220 VAC power, includes 300mA 24VDC auxiliary device power supply. 14.8k words total (7679 words ladder - flash, 7488 words V-memory), RLL/RLLPLUS programming (DirectSOFT32 Version 4.0 or higher), two built-in RS-232C communication ports. Secondary communications port supports RS-232C/RS-422/RS-485, DirectNET Master/Slave,