產(chǎn)品簡介:
, 500va
built-in withstanding/insulation tester
500va test capacity
zero turn on operating switch
automatic ng indicator of alarm lamp and buzzer
lower set for no-contact judge
digital cut-off current set
test on and result output signal
auto w-i and i-w test procedure
optional : remote control box ght-106r
基本參數(shù):
交流耐壓測試 | 電壓 | 0 ~ 2.5kv, 0 ~ 5kv 共 2 檔 ac line waveform | | 電壓調(diào)節(jié)率 | 20% | | zui大電流 | 100ma | | 參考值 | 設(shè)定 | 0.5, 1, 2, 4, 8, 10, 100ma 共 7 檔, combination of from 0.5 ~ 25.5ma ranges | | low reference | 由 0 ~½ 的 reference value 連續(xù)可調(diào) | | 表頭 | | 2.5kv, 5kv 共 2 檔, ±3% 滿刻度 | 電流監(jiān)看表頭 | | ±5% 滿刻度 | 絕緣阻抗 | 直流電壓 | 500v/1000v | | 阻抗范圍 | 1 ~ 2000mω | | 阻抗準(zhǔn)確度 | 5% ~ 10% 視檔位而定 | | judgement | desc-ription | window comparator system | | 準(zhǔn)確度 | ±10% ~±20% 視檔位而定 | | 計時器 | | 0.5秒 ~ 10分鐘 | 基本功能 | 測試方式 | 自動 w-i、自動 i-w、手動 w、手動 i | | 遙控控制 | 可做測試、清除與計時器開啟/關(guān)閉控制 | | 輸出信號 | test on, good, ng, and read signal (the rating of the contact signal are 110vac 1a or 30vdc 1a) | | ac outlet | use only buzzer and warning light, the output voltage depend on the line voltage and the current is 1a | | 測試模式 | double action, good hold, momentary, ng alarm | | 使用電源 | | 交流 120v±10%, 50/60hz (交流 220v/240v order made) | 附件 | | 電源線 x 1, 操作手冊 x 1, 測試線 ght-105 x 1, (ght-106r 選購配備) | 尺寸及重量 | | 430(寬) x 223(高) x 510(長) mm 約 28 公斤 |
|
|
選購配件 型號 | 名稱 | 說明 | ght-106r | remote controller | gpi-625 |
|