美國Oakton實驗室電導(dǎo)率儀器CON510訂貨號EC-CON510-43S成套CyberScan CON 510電導(dǎo)率/TDS 儀表帶電極, 連體電極支架和通用穩(wěn)壓電源.
美國Oakton實驗室電導(dǎo)率儀器CON510可以測量電導(dǎo)率、總?cè)芙夤腆wTDS和溫度;精度高,穩(wěn)定性好,經(jīng)久耐用,性價比高,電極常數(shù)可選。多達(dá)5個量程自動識別,提供精確、穩(wěn)定的電導(dǎo)率測量。
.量程:
CON: 0~19.99, 20~199.9µS/cm
200~1999µS/cm;2~19.99mS/cm,20~199.9mS/cm
TDS: 0~9.99,10.0~99.9,100~999ppm;
1.00~9.99,10~99.9ppt
.分辨率 0.01/0.1µS/cm,0.01/0.1mS/cm
.分辨率0.01ppm/0.1ppm/1ppm/0.01ppt/0.1ppt
.精度:全量程的±1%
.溫度測量范圍 0 -80℃
.分辨率0.1℃
.精度精度:±0.5℃
.校準(zhǔn)點:自動4點 /手動5 點
.記憶 100 組數(shù)據(jù)
.操作溫度:0 -50℃
.顯示:LCD(5.9×3.2cm)
.輸入:DC sockets,6針接口
.電源 9V穩(wěn)壓電源 300mA(100/240VAC,SMPS)
.尺寸/重量:23×18×6cm/750g(單機(jī));
41.5×25.5×9cm/1100g(裝箱)
美國Oakton實驗室電導(dǎo)率儀器CON510英文介紹:
Dual display shows both conductivity or TDS and temperature in 癈 or 癋
Single- and multi-point automatic or manual calibration: customize meter calibration for quick checks or for best meter accuracy
Auto ranging across five ranges: offers the best resolution for your measurements
Advanced set up mode: recalls previous calibration data, conductivity/TDS effective cell constants per range, and more
Built-in non-volatile memory: stores up to 50 conductivity or TDS readings with corresponding temperature
Automatic or manual temperature compensation
Selectable cell constant
Adjustable conductivity to TDS conversion factor and temperature coefficient: gives highest accuracy in any solution
Selectable normalization temperature: choose between 15癈 and 20癈
Built-in electrode holder arm; selectable "Ready" indicator; Hold function; diagnostic error messages
Includes WD-35608-50 conductivity cell
Measures | Conductivity, TDS, 癈, 癋 |
ConductivityRange | 0 to 19.99 0 to 199.9 0 to 1999 礢 0 to 19.99 mS 0 to 199.9 mS |
ConductivityResolution | 0.01 礢 0.1 礢 1 礢 0.01 mS 0.1 mS |
ConductivityAccuracy | ?% full scale or ? digit |
ConductivityCalibration | Automatic: single or multi-point up to 4 points (84 礢,1413 礢, 12.88 mS, 111.8 mS) Manual: single or multi-point up to 5 points (one user selectable point per range for multi-point calibration) |
TDSRange | 0.00 to 9.99 ppm 10.0 to 99.9 ppm 100 to 999 ppm 1.00 to 9.99 ppt 10.0 to 99.9 ppt 100 to 200 ppt |
TDSResolution | 0.01 ppm 0.1 ppm 1 ppm 0.01 ppt 0.1 ppt |
TDSAccuracy | ?% full scale or ? digit |
TDSCalibration | Automatic: single or multi-point up to 4 points (84礢, 1413礢, 12.88mS, 111.8mS) Manual: single or multi-point up to 5 points (one user selectable point per range for multi-point calibration) |
TemperatureRange | 0.0 to 100.0癈 32 to 212.0癋 |
TemperatureResolution | 0.1癈 or 癋 |
TemperatureAccuracy | ?.5癈 or ?.9癋 |
TemperatureCalibration | offset 0.1?increments up to ?? |
Memory | up to 50 sets with temp |
Cell constant | selectable 0.1, 1.0, 10 |
Temperature coefficient | adjustable from 0 to 10% per 癈 or 癋 |
Dimensions | 9"W x 2-3/8"H x 7"D |
Shipping weight | meter only 1.25 lbs. (0.6 kg); boxed 3 lbs (1.4 kg) |