      當前位置:卓爾瑞華(北京)科技有限公司>>WIKA壓力及溫度儀表>> 712.15.160WIKA 712.15.160 Cryo Gauge® 低溫冷凍行業(yè)用全鋼差壓壓力表

      WIKA 712.15.160 Cryo Gauge® 低溫冷凍行業(yè)用全鋼差壓壓力表

      參  考  價面議
      具體成交價以合同協(xié)議為準

      產(chǎn)品型號712.15.160

      品       牌

      廠商性質(zhì)代理商

      所  在  地北京市

      更新時間:2022-03-27 08:03:23瀏覽次數(shù):313次

      聯(lián)系我時,請告知來自 智能制造網(wǎng)
      WIKA 712.15.160 Cryo Gauge® 低溫冷凍行業(yè)用全鋼差壓壓力表

      zui大工作壓力: 712.15.160 Cryo Gauge(Mpa) 型號: 712.15.160 Cryo Gauge
      適用范圍: 低溫冷凍行業(yè) 精度等級: 1.6
      品牌: WIKA/威卡 加工定制:
      量程范圍: 0-140 to 4000mbar(kPa) 外形尺寸: 160(mm)

      WIKA 712.15.160  Cryo Gauge®

      低溫冷凍行業(yè)用全鋼差壓壓力表

      Differential pressure gauge
      Model 712.15.160, Cu-alloy
      Model 732.15.160, stainless steel version



      Differential pressure gauge
      Model 712.15.160, Cu-alloy
      Model 732.15.160, stainless steel version

       

          Applications
           Level measurements in closed tanks, particularly in cryotechnology
           Filter monitoring
           Monitoring and control of pumps
           For gaseous and liquid media that are not highly viscous or crystallising and have no suspended solids


         Special features
           Differential pressure measuring ranges from 0 … 40 mbar to 0 ... 4,000 mbar
           High working pressure (static pressure) of 50 bar
           Overpressure safety either side up to 50 bar
           Scaleable measuring ranges (maximum Turn Down of 1 : 3.5)
           Very compact design
           Optionally compact valve manifold with working pressure

      indication

       

       

         Description
          These high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks.


          With only 6 different measuring cells all usual tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270 degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and easily.


          An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument.

       

          The level display can be supplied with an optional, integrated 4 … 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure can be retrofitted on site.


          The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.

       

         Design and operating principle
          Pressures p1 and p2 act on the media chambers ⊕ and ?, which are separated by an elastic diaphragm (1).


          The differential pressure (Δp = p1 - p2) leads to an axial deflection of the diaphragm against the measuring range spring (2).


          The deflection, which is proportional to the differential pressure, is transmitted to the movement (5) in the indicating case (4) via a pressure-tight and low friction lever mechanism (3).


          Overpressure safety is provided by metal bolsters (6) resting against the elastic diaphragm.

         

         Standard version


         Differential pressure gauge
          Model 712.15.160
          Model 732.15.160

         

         Illustration of the principle

         

          Mounting according to affixed symbols
          ⊕ high pressure and ? low pressure

       

         

         Span adjustment
          The measuring span of the differential pressure gauge can, depending on the particular measuring cell used, be adjusted within the measuring range limits given in the previous specifications table. Ideally, this adjustment should be made on a test bench, though it can also be carried out at the measuring point using a hand test pump.

         

          The span adjustment, situated at the 4 o‘clock point on the case circumference, is accessible by removing the cover cap. With the gauge subject to the desired nominal pressure, insert a hexagon screwdriver (SW 3 mm) into the funnel guide, and adjust the pointer to the final value by turning it clockwise (for a lower measuring range) or anti-clockwise (for a greater measuring range). The gauge will then be fully adjusted to the required measuring range. If the gauge is equipped with a transmitter model 89x.44, then this procedure will also adjust the output signal to the new measuring range. After completing the adjustment the instrument should be re-sealed with the cover cap.

       

         Scale designs
          The dials can be made to customer‘s requirements and also with multiple scales. In addition, up to three different, interchangeable slip-on dials can be supplied, e.g. for measuring different media.
          These can be printed with all usual units on them, e.g. kg, litre, m3, mmH2O, inchH2O, % etc.. Red marks for maximum fill level, customer logos and other custom printing are likewise possible. If desired, we can carry out the calculation for the tank fuel level from drawings of the tank geometry, and then make the appropriate scales.

       

          Dimensions in mm

         

          CE conformity
          EMC directive
         2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application)


          ATEX directive 1)
         94/9/EC, II 2 G Ex ia IIC 1) Option

       

         Approvals
           GOST-R, import certificate, Russia
           GOST, GOST, metrology/measurement technology,
              Russia (only for model 712.15.160)
           BAM, oxygen application (only for model 732.15)

       

          Approvals and certificates, see website

       

         Option
          Valve manifold (wetted)
          with mounted working pressure gauge

         



          With a single order, all parts necessary for the fitting to the differential pressure gauge are included in the delivery: 4 x hexagon screws M8 x 16 , 2 x O-ring seal

       

         

       

         

       

         

       

         Option


         Switch contacts
          for level and/or working pressure indicators


          A modular system of electromechanical and electronic switch contacts with plug connection, also suitable for retrofitting on site, can be fitted both to the level display and to the working pressure indication. They consist of self-contained units, which can be fitted to any pointer pressure gauge within a few minutes. The connection to the instrument pointer is made by means of a special yoke so that a carrier pin at the pointer itself is not needed. The set value pointer of the
      installed switch contacts are adjusted, from the outside, to the value at which the switching operation is to take place, using the adjustment lock with a separate or integral key. A coupler connector, an M3 x 20 centring screw and a seal are
      included in the delivery.

       

          Switching functions
          The following applies, as a general rule, to the contact functions of the model 828 1) magnetic snap-action contacts in connection with our standard settings:Index 1 according to the contact type no. means:
          Contact closes the circuit when the set point is exceeded Index 2 according to the contact type no. means:
          Contact opens the circuit when the set point is exceeded Index 3 according to the contact type no. means:
          When the set value is exceeded, one circuit is opened and one circuit is closed simultaneously (change-over contact)


          The following applies, as a general rule, to the contact functions of the model 838 1) inductive contacts in connection with our standard settings:
          Index 1 according to the contact type no. means:
          Contact closes the control circuit when the set point is exceeded (flag disengages from control head)
          Index 2 according to the contact type no. means:
          Contact opens the control circuit when the set point is exceeded (flag engages with control head)
          The switching functions are based on a clockwise rotational motion of the instrument pointer.

       

         

         Dimensions in mm

         

          Option
          Panel mounting

         

         Ordering information
          Model / Scale range (measuring cell) / Scale design / Process connections with centre distance / Options

         

       