參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)DW
品 牌
廠商性質(zhì)代理商
所 在 地北京市
更新時(shí)間:2022-03-27 08:03:23瀏覽次數(shù):204次
聯(lián)系我時(shí),請(qǐng)告知來自 智能制造網(wǎng)Zoriver FE 五閥組 與差壓表 差壓變送器 液位計(jì)配合使用
WIKA SC15 組合式機(jī)械溫度調(diào)節(jié)器 帶微動(dòng)開關(guān) 表圓60 80
WIKA SB15 汽包式溫度計(jì) 安全溫度限定器 表圓60 80 蒸汽
WIKA TFS35雙金屬溫度開關(guān)Bimetal temperatur
額定電壓: | 220(V) | 類型: | 機(jī)械壓力開關(guān) |
zui大工作壓力: | 160bar(Pa) | 型號(hào): | DW |
額定電流: | 15(A) | 品牌: | WIKA/威卡 |
機(jī)械壽命: | 100(萬次) | 產(chǎn)品認(rèn)證: | CE |
加工定制: | 是 |
WIKA DW 不銹鋼 差壓開關(guān) 較高觸點(diǎn)負(fù)載能力
高靜壓160bar IP65
Differential pressure switch
Stainless steel version, IP 65
Model DW
Differential pressure switch model DW
Applications
■ Differential pressure monitoring and direct switching of electrical loads
■ For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive ambience
■ Process industry: chemical/petro-chemical, on- and offshore, technical gases, environmental technology,machine building and general plant construction, water treatment, pharmaceutical industry
■ Pump monitoring and control / filter monitoring, level measurement in closed tanks
Special features
■ Case made of stainless steel
■ Ingress protection IP 65, NEMA 4
■ Ambient temperature -30 ... +85 °C
■ 1 or 2 independent switch points, high contact rating up to 15 A / AC 220 V
■ Working pressure (static pressure) up to 160 bar
Description
These high-quality differential pressure switches have been developed especially for safety-critical applications. High quality and product manufacturing to ISO 9001:2000 ensures reliable monitoring of your plant. In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested.
All wetted parts materials are from stainless steel or Inconel 718, depending on the measuring range. Each switch family is available in IP 65, Ex-ia or Ex-d versions (Ex-d see model DA, data sheet PV 35.43).
In order to ensure as flexible operation as possible, the pressure switches are equipped with micro switches, which make it possible to switch an electrical load of up to 15 A /AC 220 V directly. For smaller contact ratings, such as for PLC applications, argon gas filled micro switches with gold-plated contacts can be selected as an option.
By using a liquid-filled diaphragm measuring cell with fulcrum lever transmission, the model DW pressure switch is extremely robust and guarantees optimal operating characteristics.
Switch points
The switch points can be set to your requirements, free-ofcharge.
Please specify:
Switch point, switching direction for each contact (e.g. switch point 1: 0.5 bar, falling, switch point 2: 3 bar, rising)
With two micro switches, the switch points can be set independently of each other.
After unscrewing the case cover, switch point adjustment can be made using the adjustment screw. The switch point is settable within the entire measuring range with the following
general rule:
■ Define the value A = 2x repeatability + switch hysteresis
■ If the pressure is rising, the switch point should be set between (min. + value A) up to max. of the setting range.
■ If the pressure is falling, the switch point should be set between min. up to (max. - value A) of the setting range.
Example:
Setting range: 0 ... 1 bar with one switch contact Repeatability: 1 % of 1 bar = 10 mbar
Switch hysteresis = 15 mbar (see table setting ranges) Value A = 2 x 10 mbar + 15 mbar = 35 mbar
If the pressure is rising, the switch point should be set between 35 mbar up to 1 bar.
If the pressure is falling, the switch point should be set between 0 up to 965 mbar.
For optimal performance we suggest the switch point lies between 25 % and 75 % of the setting range.
Electrical connection
½ NPT female, cable connection using internal terminal block, protective conductor connection using internal and external screw, max. earth cable cross-section 4 mm2
Pressure switch certified per:
■ Pressure equipment directive 97/23/EC (PED, annex 1,category IV, safety accessories, module B + D)
■ Low voltage directive 73/23 EEC and 93/68 EEC
Dielectric strength
Safety class I (EN 61298-2: 1997-06)
Mounting
Direct or wall mounting
Preferred connection location of the process connection should be below.
Weight
approx. 6.2 kg
Options
■ Other process connection, also with adapter
■ Electrical connection 3/4 NPT, G 1/2, G 3/4 or M20 x 1.5(female)
■ Cable gland on request
■ Plus/minus setting ranges (e.g. -200 ... +200 mbar)
■ 2" pipe-mounting kit (with clamping element)
■ Version for off-shore 3) or tropicalised application 3)
■ Version for applications to NACE 3)
■ Version for ammonia applications 3)
■ Oil and grease free version for oxygen applications
■ Wetted parts made of Monel
■ Design per
GAS Ex-ia IIC T6 and T4
Dust Ex-iaD A20 IP65 T85 and T135 3)
Electrical characteristics: Ui = 30 V
Ii = 100 mA
Pi = 0.75 W
Ci = 0 μF
Li = 0 mH
■Accessories:
Three-way or five-way valve
3) Inert gas filled contacts required
4) Max. 1 switch contact
Approvals and certificates
■ SIL 2 version 3) 4)
■ GOST-R certificate
■ Test certificate *CA* (confirmation of the switchingaccuracy)
■ Test report *CP* (3-time listing of the switch point, requiresswitch point specification)
■ Material certificate 3.1 per EN 10204