      當前位置:卓爾瑞華(北京)科技有限公司>> AB9200德國MT 防爆感應式電接點壓力表

      德國MT 防爆感應式電接點壓力表

      參  考  價面議
      具體成交價以合同協(xié)議為準

      產品型號AB9200

      品       牌

      廠商性質代理商

      所  在  地北京市

      更新時間:2022-03-27 08:03:23瀏覽次數:328次

      聯(lián)系我時,請告知來自 智能制造網
      同類優(yōu)質產品更多>
      是否提供加工定制 是 品牌 德國MT AB
      型號 9200 類型 電接點壓力表
      測量范圍 100(MPa) 精度等級 1
      聯(lián)接型式 G1/2 公稱直徑 100 160(mm)
      環(huán)境溫度 -40-70(℃)

      * 德國制造

      質量管理符合 DIN EN ISO 9001:2008

      俄羅斯GOST認證         德國船級社認證

      俄羅斯GOST –           R認證俄羅斯海洋注冊登記證

      烏克蘭GOST認證         EHEDG歐洲衛(wèi)生工程及設計工作組認證

      哈薩克斯坦GOST認證     3A認證

       

      Limit Switch Contact Assemblies
      Inductive

       

          This data sheet contains important details of the available make/ break operations and electrical connections of inductive limit switch contact assemblies. Detailed information about operation method and application of all our limit switch contact assemblies are given in our general information leaflet 9000.
          For pressure gauges with built-in limit switch contact assemblies special data sheets with dimensional drawings and details of the ordering codes can be found under the different catalogue headings, ending on number ..90, ..91 or ..19.1

          Make/Break Operations
          The available make/break operations of single and double contacts are shown in the table below.
          Code letter I = Inductive limit switch
          Code no. 1 = making contact, closes when the set point is passed by in clockwise direction (i.e. opens counterclockwise)
          Code no. 2 = breaking contact, opens when the set point is passed by in the clockwise direction (i.e. closescounterclockwise)

          Circuit diagrams of three and four contacts are available upon request. Make/break operations must be stated for clockwise pointer movement, e.g.: 1stcontact: breaking 2nd contact: breaking 3rd
          contact: making
          It is not possible for all the set pointers to be set one above the other.
          Therefore you should always state where the set points are.

       

          Adjustment
          The set points are adjustable from outside. The material of the adjustment depends on pressure gauges model and version:
          – Cast into the acrylic glass window, or
          – Nickel plated brass, built into the window; removable key;

          Electrical Connections
          Terminal box, mounted on the case. For the precise location of this box see data sheets of the individual pressure gauge models.
          The terminals in the connecting box are also numbered as shown in the circuit diagrams. A ground terminal is provided.

         Special Options
          • 4-fold inductive limit switch upon request (restrictions because of the required front-to-back case size)
          • 2 limits with fixed distance (e.g. distance 3 <°)
          •Double inductive limit switch nom. size 160 (6") as "interval switches" for low torques, e.g. for test gauges (accuracy class .6)
          The actuator vane is here fastened to the instrument pointer. If using the especially for this limit-switch developed output unit WE../Ex-JR it is guarantied that after the actuator vane has passed the limit and the switching operation took place, the switching function will maintain even if the set limit values are exeeded. The actuator vane can pass the set point, pass the slot
      and re-enter the slot again on its the way back without any change of switching behaviour. Even a power failure cannot cause any change in the switching behaviour. When the power is supplied again, the latest switching position will be likewise restored.
          •Adjustment device with non removable key nickel plated brass; Adjustment device stainless steel with removable or non-remove- able key upon request
          •Safety slotted version SN; if used together with an intrinsically safe output unit it may be applied for a self-controlled control system  (intrinsincally safe circuit). If there is a failure, either in the slot sensor or in the output unit, the output signal will turn to  "0".
          This construction is TÜV approved for the safety requirements of important control systems. The electrical data fulfill the standards of EN 60947-5-6 respectively NAMUR.
          •Safety slotted version S1N, with reversed direction of action