The terminals in all aspects under 500 Caledon role, in 10 seconds, without any loss, damage and other negative phenomena, but also bending.
4.0 電氣性能Electrical Performance
A 額定電流Current ratings:DC 12V 1A.
B 接觸電阻Contact resistance:50mΩ以下.
C 絕緣電阻Insulation Resistance:
在端子之間各端子與殼之間加AC 500V 條件下,持續(xù)1分鐘測(cè)試.100mΩ以上. The terminal between the terminal and Shell in between 500V AC conditions, sustained a minute test Ω m above .100.
D 抵抗電壓Resistance voltage:
在端子之間端子與殼之間加 AC 500V 60Hz 條件下,持續(xù)1分鐘測(cè)量.無(wú)擊穿現(xiàn)象出現(xiàn). In between the terminal and the terminal shell in between AC 500V 60Hz conditions, sustained a minute measurement. No breakdown phenomenon.
5.0可靠性試驗(yàn)Reliability Test
A 壽命試驗(yàn)Life Test
以涂有薄層潤(rùn)滑脂的插頭(涂潤(rùn)滑脂防止摩擦過(guò)熱)以每分鐘15~20次,無(wú)負(fù)載插座撥出5,000次,符合規(guī)格3.0和4.0規(guī)定值. Coated with a thin layer of grease plugs (TU Grease prevent friction overheated) per minute to 15 ~ 20, a no-load socket allocated 5,000, with the specifications 3.0 and 4.0 provides value
B 溫度試驗(yàn)Temperature Test
將插座放置于40±2℃,相對(duì)溫度90%~95%環(huán)境中,96個(gè)小時(shí)后取出,取去水滴,將插座放置于常溫常濕環(huán)境中,于30分鐘內(nèi)測(cè)試,符合規(guī)格3.0和4.0要求. Socket to be placed on the 40 ± 2℃, relative humidity of 90% ~ 95% of the environment, 96 hours after the removal, taking a drop of water, will be placed in the socket temperature often wet environment, in the test within 30 minutes, with 3.0 and 4.0 specifications required.