      UV-3711-308探測(cè)器Gigahertz-OptikThedetectorUV-3711-308isdesignedforirradiancemeasurementof308nmEximerlasersusedinmonochromaticUV-Btherapyfortreatmentofpsoriasisandvililigo

      詳細(xì)介紹

      UV-3711-308探測(cè)器Gigahertz-Optik

      The detector UV-3711-308 is designed for irradiance measurement of 308nm Eximer lasers used in monochromatic UV-B therapy for treatment of psoriasis and vililigo. The flat spectral responsivity around the 308 nm reduces the measurement uncertainty in case of wavelength shift of the Eximer laser.

      Traceable calibration

      Calibration of the detector UV-B (W/m2) responsivity at 308nm is performed by the Gigahertz-Optik GmbH calibration laboratory for optical radiation measurements quantities. As with all light detectors supplied by Gigahertz-Optik calibration of absolute detector responsivity as well as detector individual measured relative spectral responsivity data is included

      Spectral functionUV-B 308 nmTyp. Responsivity3 n/(W/m2)Max. signal current50 µAMin. signal current

      depends on optometer

      Measurement entrance11 mm ? diffusor windowMeasurement entranceCosine F.O.V.Housing

      37 mm ?, 50 mm height

      Mountside M6 thread holeConnection cablecoaxial cable 2 m Long, with BNC (-1), calibration data (-2) or ITT (-4) connectorOperation temperature

      (5 - 40) °C

      Re-calibrationK-UV3711-308-S

      Calibration of irradiance responsivity in A/(W/m2) using a monochromatic 308 nm reference lamp.

      P-9710High-quality device for measurement of CW-, single pulse and modulated radiation.

      Features: Optometer for all detector heads with calibration data plug. Measurement modes: CW, pulse energy, dose, peak-to-peak, effective luminous intensity (Blondel-Rey), data logger, battery, main power, RS232X1Four-channel USB optometer designed for use.

      Features: Compact device for use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik. USB interface. Battery operation or power supply USB.X1-RMOptometer in 3HE housing for use in 19" racks.

      Features: Its USB and RS232 remote interface and two additional RS232 device interfaces make the device highly flexible when it comes to system integration. Its four signal inputs enable use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik.X1-PCBOptometer module.

      Feature: The X1 optometer is available as a printed circuit board either with or without a housing and is suited for applications that do not require a keyboard or display. Four signal inputs enable connection with all measuring heads from Gigahertz-Optik.P-2000Two-channel optometer.

      Features: For use with most photometric and radiometric detectors supplied by Gigahertz-Optik. Modes: CW, pulse energy from both single and multiple flashes, effective luminous intensity (Blondel-Rey), data logger and others.P-9801Eight-channel optometer.

      Features: State-of-the-art 8 channel laboratory optometer with a signal amplifier and sample & hold ADC per channel for clocked recording of the measurement signals. RS232 and IEEE488 interface. Trigger input and output.P-9802Light meter for laboratory use with up to 36 measurement heads.

      Features: For use with up to 36 photometric and/or radiometric measurement heads. RS232 interface.P-9202-4Fast response time trans-impedance signal amplifier.

      Features: High quality analogue amplifier with current-voltage conversion. Minimal diode offset voltage for short circuit operations. Bandwidths of up to 330kHZ. 1µs rise time. Large I-U amplification range from 10pA/V to 1mA/V.P-9202-5Universal trans-impedance signal amplifier.

      Features: High quality analogue amplifier with current-voltage conversion. Minimal diode offset voltage (1mV) for short circuit photodiode operations. 5µs to 20ms rise time depending on the amplification. Large I-U amplification range – 1×10-10A/V to 1×10-3 A/V.P-9202-6Highly sensitive trans-impedance signal amplifier.

      Features: High quality analogue amplifier with current-voltage conversion with minimal diode offset voltage (0.5mV) for short circuit photodiode operation of . 2.5s to 25s rise time depending on the amplification. Large I-U amplification range – 1×10-11A/V to 1×10-4 mA/V.TR-9600High-speed 1µs or 100ns rise time data logger optometer.

      Features: Laboratory device for recording of clocked intensity progress readings in single light flashes, flash sequence or modulated light. Calculation of pulse data e.g. peak intensity, pulse length, pulse half width , pulse energy and pulse repeat rate, etc.X1-PCBCOptometer module.

      Feature: The X1 optometer is available as a printed circuit board either with or without a housing and is suited for applications that do not require a keyboard or display. Four signal inputs enable connection with all measuring heads from Gigahertz-Optik.

      xx UV-3711-308-1

      Detector head with -1 connector, calibration certificate.

      101836-1 UV-3711-308-2

      Detector head with -2 connector, calibration certificate.

      xx UV-3711-308-4

      Detector head with -4 connector, calibration certificate.

      Calibration
      K-UV3711-308-S

      Re-calibration of integral irradiance responsivity in A/(W/m2) at 308nm with calibration certificate.

      K-UV-SR

      Re-calibration of the relative spectral responsivity from.

      關(guān)鍵詞:探測(cè)器
      其他推薦產(chǎn)品更多>>

      感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

      智能制造網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://towegas.com,All rights reserved.

      以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

      會(huì)員登錄

      ×

      請(qǐng)輸入賬號(hào)

      請(qǐng)輸入密碼

      =

      請(qǐng)輸驗(yàn)證碼

      收藏該商鋪

      請(qǐng) 登錄 后再收藏

      提示

      您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~