PANELPOWERMETER/KDX-TypeTypeKDX-A1N/CKDX-A2N/CKDX-B1N/CKDX-B2N/CMeasurement3V,3A,W,PFvar,Hz,Wh,varh3V,3A,W,PFvar,HzInputDirectWithP
PANEL POWER METER / KDX- Type Type KDX-A1N / C KDX-A2N / C KDX-B1N / C KDX-B2N / C Measurement 3 V, 3 A, W, PF var, Hz, Wh, varh 3 V, 3 A, W, PF var, Hz Input Direct With P.T Direct With P.T Communication N O C X Line Voltage Current Fower Factor 10 ~ 500V 0.1 ~ 6A 0.5 ~ 1.0 1 2W, 1 3W 3 3W, 3 4W Function Using one-touch button, display to select the following values - W, PF, Var, Hz, Wh, Varh. It can adjust the rate of P.T / C.T at user’s options.. The system is provided with RS-485 serial multi-communication function. * . Division PORTABLE POWER METER / KDPM-AType Function The Power Meter indicator 8 measuring V, A, W, PF, Var, VA, Wh, Ah by use of 3 displays, and in the back side, the measuring value is put out to RS232C, and then can be connected with the computer and keep the record. * . Specifications PORTABLE POWER TESTER / KDPT- Type KDPT-1 2.00~20.00A 125~5000W KDPT-2 0.500~5.000A 25.0~750.0W 30.0~300.0V 50.0~100.0 KDPT-3 0.200~2.000A 10.0~500.0W KDPT-4 50.0~999.9mA 2.50~99.99W Accuracy (0.2% of rdg+0.1% of FS) Input Division Function In indicates the basic value of Ac electrical equipment, V, A, W, PF at the numeric value at the same time. The judgement of products under the inspection appear as the alarm and the contact output by the limit-setting part, and thus the outside confirmation is convenient. it can be kept or transmitted to Print or RS-232C. * . Specifications Measure Area ) W H D 144 144 150 Unit : mm Dimension Max Display LED Display Update Time 5000 14.2(0.56 )mm/Red 1000ms Display V (0.5% of FS+1digit) A (0.5% of FS+2digit) W (0.5% of FS+2digit) var (1.5% of FS+2digit) PF (3% of FS+2digit) Hz (0.1% of rdg+2digit) Wh (1.0% of rdg count+2digit) varh (3.0% of rdg+2digit) Accuracy AC A W AC V PF Principle Measurement Range Crest Factor 5range of mean value rectification and true RMS by LOG-anti LOG 0 50, 0 100 0 150, 0 200 0 300 7range of mean value rectification and true RMS by LOG-anti LOG 0 0.3, 0 0.5 0 1, 0 2, 0 5 0 10, 0 20 2.0 2.0 45 65Hz (0.2% of rdg + 0.1% of range) Principle : W Measuring range : 0.100 1.000 V A Accuracy : (0.2% of rdg +2.0% of range) Principle : V A Measuring range : 1.50 6000VA Accuracy : (0.2% of rdg +0.5% of range) Principle : (V A)2-W2 Measuring range : 15 6000var Accuracy : (0.5% of rdg +1.0% of range) Accuracy : (0.5% of rdg+1.0% of range) Accuracy : (0.2% of rdg+1.0% of range) 0.03% of range/ Wh Ah Temperature Coefficient 5 to 20 ( , 10Hz 45~65Hz 2kHz 20kHz 1% of range 1% of range 2% of range 3% of range 45 65Hz (0.1% of rdg + 0.2% of range) At cos =1 (0.2% of rdg + 0.2% of range) PWM time division multiplication 1.5 6000W Input Division AC V AC A W Customer’s specifications and changes of designs are possible. W H D 270 100 400 Unit : mm Dimension PORTABLE POWER METER / KDPM- Type KDPM-1 2.00~20.00A 125~5000W KDPM-2 0.500~5.000A 25.0~750.0W 30.0~300.0V 50.0~100.0 KDPM-3 0.200~2.000A 10.0~500.0W KDPM-4 50.0~999.9mA 2.50~99.99W Accuracy (0.2% of rdg+0.1% of FS) Input Division Function 3 V, A and W£ØPF are displayed via 3EA of display screens, and W and PF are displayed by each selection. It is also the device which preserves the data through the computer. * . Specifications AC A W AC V PF Customer’s specifications and changes of designs are possible. W H D 270 100 400 Unit : mm Dimension W H D |