国产强伦姧在线观看无码,中文字幕99久久亚洲精品,国产精品乱码在线观看,色桃花亚洲天堂视频久久,日韩精品无码观看视频免费

      TILO天友利/上海卡羅卡超儀器有限公司

      當(dāng)前位置:TILO天友利/上??_卡超儀器有限公司>> ETC-TE095-A280鏡頭攝像透射式測(cè)試卡,攝像頭反射式測(cè)試卡,深圳愛薩測(cè)試卡,DNP測(cè)試卡價(jià)格

      鏡頭攝像透射式測(cè)試卡,攝像頭反射式測(cè)試卡,深圳愛薩測(cè)試卡,DNP測(cè)試卡價(jià)格

      參  考  價(jià):面議
      具體成交價(jià)以合同協(xié)議為準(zhǔn)

      產(chǎn)品型號(hào)ETC-TE095-A280

      品牌

      廠商性質(zhì)生產(chǎn)商

      所在地深圳市

      更新時(shí)間:2018-05-15 13:31:28瀏覽次數(shù):1676次

      聯(lián)系我時(shí),請(qǐng)告知來(lái)自 智能制造網(wǎng)
      鏡頭攝像透射式測(cè)試卡,攝像頭反射式測(cè)試卡,深圳愛薩測(cè)試卡,DNP測(cè)試卡價(jià)格
      國(guó)愛莎ESSER攝像機(jī)測(cè)試卡(ESSER TEST CHART),攝像機(jī)測(cè)試卡應(yīng)該是視頻攝象機(jī)日常使用及定期檢修時(shí)*的工具

      T03
      t03_s
      Depth Of Modulation 0.5 / 5 MHz
      The T03 is designed for evaluating the uniformity of the modulation depth of TV cameras. Between the line raster rows two white bars of different lengths are arranged on a black background (upper part) resp. two black bars of different lengths are arranged on a white background (bottom part).
      TE94
      te94
      ITE Radial Resolution Chart
      The TE94 ist designed for checking resolution over the whole picture area. It consists of nine sector stars of 90 (black and white) sectors each. Resolution measurement with TV lines is independent from TV standard.
      TE99
      te99
      Multi Burst Test Chart (High-Class in Mega Cycle Chart)
      The TE99 is designed to measure frequency response of the modulation depth of electronic cameras. A line raster is arranged in the center of the test chart which produces frequencies of 0.5 to 10 MHz in the output of the TV camera. Bar rasters are located in the corners of the test chart and produce frequencies of 0.5 and 5 MHz.
      TE103
      te103
      Multi Burst Test Chart 1-6 MHz (positive)
      The TE103 is designed for resolution measurements, mainly for visual tests. It consists of eight rows with each six fields of multiburst of frequencies (1-6 MHz).
      TE104
      te104
      Multi Burst Test Chart 1-6 MHz (negative)
      The TE104 is designed for resolution measurements, mainly for visual test. It consists of four rows with each six fields of multiburst of frequencies (1-6 MHz).
      TE107
      TE107 16:9
      te107
      Multi Burst Test Chart (0-10 MHz)
      The TE107 is designed for checking the frequency response and the uniformity of modulation depth of electronic cameras. A line raster is arranged in the center of the test chart which produces frequencies of 0.5 to 10 MHz in the output of the TV camera.
      TE118 16:9
      te118
      HDTV Resolution Test Chart (100 - 600 c/ph)
      The TE118 is designed for checking the resolution characteristics of HDTV cameras. On a black background five fields with different line rasters and black and white reference fields are arranged. The line rasters are inclined in different angles.
      TE124 16:9
      te124
      HDTV Resolution Test Chart  (100 - 600 c/ph)
      The TE124 is designed for checking the resolution characteristics of HDTV cameras.The test chart with an aspect ratio of 16:9 shows nine blocks containing 42 resolution patterns each in the middle area. The corner fields have 20 resolution patterns.
      TE135
      te135
      Multi Burst (Megacycle) Test Chart (0.5, 1, 1.5, 2, 2.5 , 3 , 5, 6 MHz)
      The test chart is designed for measuring amplitude frequency response of the luminance channel, i.e. the amplitude of the output signal relative to a reference level as a function of frequency. On a gray background a multiburst with different frequencies is shown.
      TE136
      te136
      USAF 1951 Target
      The TE136 is designed to do resolution measurements. It shows patterns - based on three black bars on white ground - in horizontal and in vertical direction.
      TE137
      te137
      Foucault Frequency Test 25-steps 2-0.5 LP/mm (set of 2 patterns)
      The TE137 is designed to do resolution measurements in a range of 2-0.5 linepairs per millimeter. Foucault patterns with horizontal, vertical and both types of diagonal resolution bw-bars are located in a matrix structure of 5 x 5 pattern on two different chart sheets
      TE138
      te138
      Line pairs per cm (1-28.5 LP/cm, set of 10 pcs.)
      The TE138 is designed to do resolution measurements. Pairs of lines with frequencies from 1-28.5 linepairs per centimeter are printed on a white background. The patterns are ordered clockwise in decreasing resolution on the chart.
      TE140
      te140
      Cine Resolution Test Chart (size A280 modified design)
      The TE140 is used for evaluating the resolving power of a cine camera. It consists of several Siemens stars and resolution patterns.
      TE142
      te142
      Cine Standard (set of 10 x 3 pattern) reprographic paper, selfadhesive
      The TE142 is designed for evaluating the resolution power of the film. It shows nine vertical and nine horizontal groups of line pairs. The gradation of these line pairs follows the factor √2.
      TE143
      te143
      ISO Test pattern No. 1 (sheet with 20 pattern; DIN 19051)
      The TE143 is designed to check the readability of the reproductions of documents. In pattern number 84 the direction of the two lines inside the octagon must be recognized without problems for seven out of eight symbols.
      TE144
      te144
      Camcorder Resolution Test Chart
      The TE144 was developed in a private German testing laboratory and serves particularly for evaluating the frequency response of consumer camcorders. The test chart is subdivided into 18 horizontal fields of bar patterns with different frequencies.
      TE149
      te149
      Universal Scanner Chart with ISO pattern No. 2
      The TE149 is designed for assessment of the image quality of scanning devices. It is composed of five test arrays with ISO test pattern no. 2, horizontal and vertical mm measuring scales of 19 resp. 28 cm length, each two horizontal and vertical length marking of 120 mm and 5’’.
      TE150
      te150
      Universal Rotative Scanner Chart with ISO pattern No. 2
      The test pattern is designed for assessment of the image quality of scanning devices. The test chart is composed of different patterns and grids.
      TE152
      te152
      Frequency Response TC (1-8 MHz continuously)
      The TE152 is designed for checking the frequency response of a camera. The test chart shows line rasters over the whole image area ranging from 1 to 8 MHz.
      TE157
      te157
      Radial Resolution Test Chart (IEC TC 84)
      The TE157 is designed for checking radial resolution of cameras. It shows a sector star with 180 sectors. One sector corresponds to an angel of 2° and has a black and a white beam.
      TE159
      te159
      Sinusoidal Multi Burst Test Chart (IEC 61146)
      (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6 MHz)

      The TE159 is designed for measuring horizontal static resolution. It shows vertical bars, the density variation of which gives a sinusoidal video response.
      TE170
      te170
      Electronic Still Picture Resolution Chart (ISO 12233)
      The TE170 chart is designed to measure resolution of still cameras. It contains resolution wedges up to 2000 lines per picture heigt. Furthermore it contains slanted edges for SFR measurements.
      TE176
      TE176 16:9
      te176
      Resolution Test Chart (Depth of modulation IEC 61142)
      The TE176 is designed for measuring resolution of electronic cameras. The test chart consists of alternating black and white bars with sharp transition. Two groups of bars with video frequencies of 0.5 and 5 MHz are distributed over the picture area.
      TE199
      te199
      Multi Burst TC 0.1-7.0 MHz in 0.1MHz steps
      The TE199 is designed for acurate resolution measurement. The chart consists of six rows with each ten fields of rectangular bursts.
      TE204 16:9
      te204
      Sinusoidal Multi Burst Test Chart (1-10 MHz)
      The TE204 is designed to measure resolution of cameras. It contains sinusoidal multiburst patterns from 0.5-10 MHz.
      TE224 16:9
      te224
      HDTV  Resolution Test Chart
      The TE224 is designed to measure and describe the frequency response of an electronic HDTV camera. The test chart consists of 50 multi burst fields, which are distributed over a 16:9 picture area. The fields are arranged in horizontal and vertical direction to measure resolution in both directions.
      TE225 16:9
      te225
      HDTV  Resolution Test Chart
      The TE225 is designed to measure and describe the frequency response of an electronic HDTV camera. The test chart consists of 32 multi burst fields, which are distributed over 16:9 picture area. The fields are arranged in horizontal and vertical direction to measure resolution in both directions.
      TE231 N 16:9
      te231
      HD Sweep Test Chart
      The TE231 is designed for checking the frequency response of HDTV cameras. The test chart shows line rasters over the whole image area ranging from 100 to 1200 lines.
      TE237
      te237
      High Resolution Sector Star Test Chart
      The TE237 serves for checking resolution over the whole picture area. It consists of sector stars of 72 (black and white) sectors.
      TE239 16:9
      te239
      HDTV In Mega Cycle Test Chart
      The TE239 is designed for checking the frequency response of modulation depth and the uniformity of modulation depth of HDTV cameras. The test chart consists of multi burst fields, which are distributed over a 16:9 picture area.The fields are arranged in horizontal and vertical direction to measure resolution in both directions.
      TE244
      te244
      IE Pattern Resolution
      The TE244 is designed to check aliasing behavior of digital cameras.
      TE245
      te245
      IE Landolt Circle Resolution
      The TE245 is designed to make a visual resolution analysis of digital cameras. It contains Landolt circles in different sizes.
      TE248 16:9
      te248
      Distortion Grid
      The TE248 is designed to measure disortion of digital cameras. It contains a fine grid of black lines on white background.
      TE249 16:9
      te249
      Scale to measure macro capabilities
      The TE249 is designed to determine the macro capabilities of a camera-lens system.
      TE250
      te250
      USAF resolution test chart 35 mm
      USAF resolution test chart on Film in 35mm . Useable for Scanner resolution up to 10000 ppi.
      TE252
      te252
      CIPA Resolution Target
      The TE252 is designed to measure resolution of digital cameras. It is described in the CIPA standard.
      TE253
      te253
      Modulated Sinusoidal Siemens Star
      The TE253 is designed for checking resolution. The chart contains a radially sine modulated Siemens star in the center of the image, gray patches and black squares with a small white square in it.
      TE253 9x
      TE253 9x
      Modulated Sinusoidal Siemens Star
      Set of 9 stars arranged in 3 columns
      The TE253 is designed for checking resolution. The chart contains nine radially sine modulated Siemens stars, gray patches and black squares with a small white square in it, slanted edges and white noise patches.
      TE265
      TE265
      Dead Leaves
      This chart contains so called dead leaves (in this case circles) structure. The structure is made of circles in all sizes and gray levels. A fourier transform of an image of this structure taken with a camera provides the power spectrum that the camera is able to reproduce

      會(huì)員登錄

      ×

      請(qǐng)輸入賬號(hào)

      請(qǐng)輸入密碼

      =

      請(qǐng)輸驗(yàn)證碼

      收藏該商鋪

      X
      該信息已收藏!
      標(biāo)簽:
      保存成功

      (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

      以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。

      溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

      在線留言