      西門子972-0BA41-0XA0
      產(chǎn)品介紹

      西門子972-0BA41-0XA0 西門子972-0BA41-0XA0 0

      SIPLUS S7-400 CPU 417English2 KB 
      possible to connect the following bus connectors to the MPI interface: With socket: 6ES7 972-0BB42-0XA0 Without socket: 6ES7 972-0BA42-0XA0 Mode selector switch: Toggle switch design. Diagnostic buffer: The last 120 fault and interrupt events...? css/ted.css The CPU 417-4 features: Powerful processor: The CPU achieves command execution times as low as0.018 µs per binary instruction. 32 MB work memory (of which 16 MB each for program and data); faster work memory for sections

       

      • 公司名稱:上海朔川電氣設備有限公司
      • 聯(lián) 系 人:吉夢琪
      • 地址:上海市金山區(qū)涇波路129號
      • 2840735331
      •  

        SIPLUS CPU 417-4

        • 訂貨數(shù)據(jù)
        •  
        • 附件
        •  
        • 產(chǎn)品信息
        •  
        • 組態(tài)工具

        跳轉(zhuǎn)到

        概述

        應用

        設計

        功能

        技術(shù)規(guī)范

        概述

        強大的 SIMATIC S7-400 CPU

        • 適用于對性能要求很高的工廠
        • 帶兩個 IF 模塊的插槽

        注:

        SIPLUS extreme 產(chǎn)品基于 SIMATIC 標準產(chǎn)品。此處列出的內(nèi)容來自相關(guān)的標準產(chǎn)品。添加了特定 SIPLUS extreme 信息。

        有關(guān) SIPLUS 的技術(shù)文檔,可訪問:
        http://www.siemens.de/siplus-extreme

        應用

        The CPU 417-4 is the most powerful SIMATIC S7-400 CPU. The integral PROFIBUS DP interfaces permit direct connection to the PROFIBUS DP fieldbus as master or slave.

        Two further DP master systems can be connected via the IF 964-DP interface submodules.

        Note:
        Only the interface module 6ES7 964-2AA04-0AB0 can be used.

        設計

        CPU 417-4 的特性:

        • 強大的處理器:
          CPU 執(zhí)行每條二進制指令時間僅為 0.018 µs。
        • 32 MB 工作存儲器(程序和數(shù)據(jù)各 16 MB);
          快速工作存儲器用于對于執(zhí)行十分重要的用戶程序部分。
        • 可靈活擴展:
          zui多 262 144 點數(shù)字量輸入/輸出和 16 384點模擬量輸入/輸出
        • MPI 多點接口:
          通過 MPI,可方便地將zui多 32 個站聯(lián)成網(wǎng)絡,數(shù)據(jù)傳輸速率可高達 12 Mbit/s。該 CPU 可與通信總線 (C-bus) 和 MPI 的站之間建立zui多 44 個連接。
          注意:
          如果 PROFIBUS DP 接口和 MPI 接口同時運行,那么只能將以下總線連接器連接到 MPI 接口:
          • 帶插口:6ES7 972-0BB42-0XA0
          • 不帶插口:6ES7 972-0BA42-0XA0
        • 模式選擇開關(guān):
          撥位開關(guān)設計。
        • 診斷緩沖區(qū):
          zui后的 120 個故障和中斷事件保存在一個環(huán)形緩沖器中,用于進行診斷(可擴展)。
        • 實時時鐘:
          CPU 的診斷報警帶有日期和時間標記。
        • 存儲卡:
          用于擴展內(nèi)置裝載存儲器。存儲在裝載存儲器中的信息包括 S7?400 參數(shù)數(shù)據(jù)以及程序,因此需要 2 倍的存儲空間。其結(jié)果是:
          • 內(nèi)置的裝載存儲器不能滿足大程序量的要求,因此需要存儲卡。
            可使用 RAM 和 FEPROM 卡(FEPROM 卡用于保持性存儲)。
        • PROFIBUS DP 接口:
          通過 PROFIBUS DP 主站接口,可以實現(xiàn)分布式自動化組態(tài),從而提高了速度,便于使用。對用戶來說,分布式 I/O 單元可作為一個集中式單元來處理(相同的組態(tài)、編址和編程)。
          混合組態(tài):SIMATIC S5,SIMATIC S7 為 PROFIBUS 主站,符合 EN 50170 標準。
          注:
          當同時使用 PROFIBUS DP 和 MPI 接口時,只能將下列總線連接器連接到 MPI 接口:
          • 帶插口:6ES7 972-0BB42-0XA0
          • 不帶插口:6ES7 972-0BA42-0XA0
        • 兩個附加插槽:
          可用 IF 964-DP 接口子模塊連接兩個附加的 PROFIBUS DP主站系統(tǒng)。

         

        • Block protection: 
          a password concept also protects the user program from unauthorized access
        • Integrated HMI services: 
          The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
        • Integrated communication functions:
          • PG/OP communication
          • Global data communication
          • S7 standard communication
          • S7 communication

        Configurable Attributes

        The STEP 7 tool "Hardware configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

        • Multipoint interface MPI:
          • Definition of node addresses
          • Startup/cycle behavior
          • Stipulation of the maximum cycle time and communication load
        • Address allocation: 
          Addressing of I/O modules
        • Retentive area: 
          Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
        • Size of the process image, local data
        • Length of the diagnostics buffer
        • Protection level: 
          Definition of access authorizations to program and data
        • System diagnostics: 
          Definition of the handling and scope of diagnostics messages
        • Timed interrupts: 
          Setting of periods
        • Configuring

        Reporting functions

        • Status and fault indicators: 
          LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc.
        • Test functions: 
          The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
        • Information functions: 
          The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

        技術(shù)規(guī)范

        Article number

        6AG1417-4XT07-7AB0

         

        SIPLUS S7-400 CPU 417-4 V7

        General information

         

        Product type designation

        CPU 417-4

        Hardware product version

        01

        Firmware version

        V7.0

        Engineering with

         

        • ● Programming package

        STEP 7 V5.4 or higher with HSP 261

        CiR – Configuration in RUN

         

        CiR synchronization time, basic load

        60 ms

        CiR synchronization time, time per I/O byte

        7 µs

        Supply voltage

         

        Rated value (DC)

         

        • ● 24 V DC

        No; Power supply via system power supply

        Input current

         

        from backplane bus 5 V DC, typ.

        1.3 A

        from backplane bus 5 V DC, max.

        1.6 A

        from backplane bus 24 V DC, max.

        600 mA; 150 mA per DP interface

        from interface 5 V DC, max.

        90 mA; At each DP interface

        Power loss

         

        Power loss, typ.

        6.5 W

        Power loss, max.

        8 W

        Memory

         

        Type of memory

        RAM

        Work memory

         

        • ● integrated

        32 Mbyte

        • ● integrated (for program)

        16 Mbyte

        • ● integrated (for data)

        16 Mbyte

        • ● expandable

        No

        Load memory

         

        • ● expandable FEPROM

        Yes; with Memory Card (FLASH)

        • ● expandable FEPROM, max.

        64 Mbyte

        • ● integrated RAM, max.

        1 Mbyte

        • ● expandable RAM

        Yes; with Memory Card (RAM)

        • ● expandable RAM, max.

        64 Mbyte

        Backup

         

        • ● present

        Yes

        • ● with battery

        Yes; all data

        • ● without battery

        No

        Battery

         

        Backup battery

         

        • ● Backup current, typ.

        225 µA; up to 40 °C

        • ● Backup current, max.

        1 275 µA

        • ● Backup time, max.

        See reference manual, module data, Chapter 3.3

        • ● Feeding of external backup voltage to CPU

        5 V DC to 15 V DC

        CPU processing times

         

        for bit operations, typ.

        7.5 ns

        for word operations, typ.

        7.5 ns

        for fixed point arithmetic, typ.

        7.5 ns

        for floating point arithmetic, typ.

        15 ns

        CPU-blocks

         

        DB

         

        • ● Number, max.

        16 000; Number range: 1 to 16000

        • ● Size, max.

        64 kbyte

        FB

         

        • ● Number, max.

        8 000; Number range: 0 to 7999

        • ● Size, max.

        64 kbyte

        FC

         

        • ● Number, max.

        8 000; Number range: 0 to 7999

        • ● Size, max.

        64 kbyte

        OB

         

        • ● Number, max.

        see instruction list

        • ● Size, max.

        64 kbyte

        • ● Number of free cycle OBs

        1; OB 1

        • ● Number of time alarm OBs

        8; OB 10-17

        • ● Number of delay alarm OBs

        4; OB 20-23

        • ● Number of cyclic interrupt OBs

        9; OB 30-38 (shortest cycle that can be set = 500 µs)

        • ● Number of process alarm OBs

        8; OB 40-47

        • ● Number of DPV1 alarm OBs

        3; OB 55-57

        • ● Number of isochronous mode OBs

        4; OB 61-64

        • ● Number of multicomputing OBs

        1; OB 60

        • ● Number of background OBs

        1; OB 90

        • ● Number of startup OBs

        3; OB 100-102

        • ● Number of asynchronous error OBs

        9; OB 80-88

        • ● Number of synchronous error OBs

        2; OB 121, 122

        Nesting depth

         

        • ● per priority class

        24

        • ● additional within an error OB

        2

        Counters, timers and their retentivity

         

        S7 counter

         

        • ● Number

        2 048

        Retentivity

         

        • — adjustable

        Yes

        • — lower limit

        0

        • — upper limit

        2 047

        • — preset

        Z 0 to Z 7

        Counting range

         

        • — lower limit

        0

        • — upper limit

        999

        IEC counter

         

        • ● Number

        Unlimited (limited only by RAM capacity)

        S7 times

         

        • ● Number

        2 048

        Retentivity

         

        • — adjustable

        Yes

        • — lower limit

        0

        • — upper limit

        2 047

        • — preset

        No times retentive

        Time range

         

        • — lower limit

        10 ms

        • — upper limit

        9 990 s

        IEC timer

         

        • ● present

        Yes

        • ● Type

        SFB

        • ● Number

        Unlimited (limited only by RAM capacity)

        Data areas and their retentivity

         

        retentive data area in total

        Total working and load memory (with backup battery)

        Flag

         

        • ● Number, max.

        16 kbyte; Size of bit memory address area

        • ● Retentivity available

        Yes

        • ● Retentivity preset

        MB 0 to MB 15

        • ● Number of clock memories

        8; in 1 memory byte

        Data blocks

         

        • ● Number, max.

        16 000; Number range: 1 to 16000

        • ● Size, max.

        64 kbyte

        Local data

         

        • ● adjustable, max.

        64 kbyte

        • ● preset

        32 kbyte

        Address area

         

        I/O address area

         

        • ● Inputs

        16 kbyte

        • ● Outputs

        16 kbyte

        of which distributed

         

        • — MPI/DP interface, inputs

        2 kbyte

        • — MPI/DP interface, outputs

        2 kbyte

        • — DP interface, inputs

        8 kbyte

        • — DP interface, outputs

        8 kbyte

        Process image

         

        • ● Inputs, adjustable

        16 kbyte

        • ● Outputs, adjustable

        16 kbyte

        • ● Inputs, default

        1 024 byte

        • ● Outputs, default

        1 024 byte

        • ● consistent data, max.

        244 byte

        • ● Access to consistent data in process image

        Yes

        Subprocess images

         

        • ● Number of subprocess images, max.

        15

        Digital channels

         

        • ● Inputs

        131 072

        • — of which central

        131 072

        • ● Outputs

        131 072

        • — of which central

        131 072

        Analog channels

         

        • ● Inputs

        8 192

        • — of which central

        8 192

        • ● Outputs

        8 192

        • — of which central

        8 192

        Hardware configuration

         

        Number of expansion units, max.

        21

        connectable OPs

        119

        Multicomputing

        Yes; 4 CPUs max. (with UR1 or UR2)

        Interface modules

         

        • ● Number of connectable IMs (total), max.

        6

        • ● Number of connectable IM 460s, max.

        6

        • ● Number of connectable IM 463s, max.

        4; IM 463-2

        Number of DP masters

         

        • ● integrated

        2

        • ● via CP

        10; CP 443-5 Extended

        • ● via IM 467

        4

        • ● Mixed mode IM + CP permitted

        No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode

        • ● via interface module

        2

        • ● Number of pluggable S5 modules (via adapter capsule in central device), max.

        6

        Number of IO Controllers

         

        • ● integrated

        0

        • ● via CP

        4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode

        Number of operable FMs and CPs (recommended)

         

        • ● FM

        Limited by number of slots and number of connections

        • ● CP, PtP

        CP 440: Limited by number of slots; CP 441: limited by number of connections

        • ● PROFIBUS and Ethernet CPs

        14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum

        Slots

         

        • ● required slots

        2

        Time of day

         

        Clock

         

        • ● Hardware clock (real-time)

        Yes

        • ● retentive and synchronizable

        Yes

        • ● Resolution

        1 ms

        • ● Deviation per day (buffered), max.

        1.7 s; Power off

        • ● Deviation per day (unbuffered), max.

        8.6 s; For power On

        Operating hours counter

         

        • ● Number

        16

        • ● Number/Number range

        0 to 15

        • ● Range of values

        SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours

        • ● Granularity

        1 hour

        • ● retentive

        Yes

        Clock synchronization

         

        • ● supported

        Yes

        • ● to MPI, master

        Yes

        • ● to MPI, slave

        Yes

        • ● to DP, master

        Yes

        • ● to DP, slave

        Yes

        • ● in AS, master

        Yes

        • ● in AS, slave

        Yes

        • ● on Ethernet via NTP

        No; Via CP

        • ● to IF 964 DP

        Yes

        Time difference in system when synchronizing via

         

        • ● MPI, max.

        200 ms

        Interfaces

         

        Interfaces/bus type

        1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 2 x PROFIBUS DP (optionally pluggable)

        Number of RS 485 interfaces

        2; Combined MPI / PROFIBUS DP and PROFIBUS DP

        Number of other interfaces

        2; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

        1. Interface

         

        Interface type

        Integrated

        Physics

        RS 485 / PROFIBUS + MPI

        Isolated

        Yes

        Power supply to interface (15 to 30 V DC), max.

        150 mA

        Number of connection resources

        MPI: 44, DP: 32

        Functionality

         

        • ● MPI

        Yes

        • ● PROFIBUS DP master

        Yes

        • ● PROFIBUS DP slave

        Yes

        MPI

         

        • ● Number of connections

        44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

        • ● Transmission rate, max.

        12 Mbit/s

        Services

         

        • — PG/OP communication

        Yes

        • — Routing

        Yes

        • — Global data communication

        Yes

        • — S7 basic communication

        Yes

        • — S7 communication

        Yes

        • — S7 communication, as client

        Yes

        • — S7 communication, as server

        Yes

        DP master

         

        • ● Number of connections, max.

        32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

        • ● Transmission rate, max.

        12 Mbit/s

        • ● Number of DP slaves, max.

        32

        Services

         

        • — PG/OP communication

        Yes

        • — Routing

        Yes; S7 routing

        • — Global data communication

        No

        • — S7 basic communication

        Yes

        • — S7 communication

        Yes

        • — S7 communication, as client

        Yes

        • — S7 communication, as server

        Yes

        • — Equidistance

        Yes

        • — Isochronous mode

        Yes

        • — SYNC/FREEZE

        Yes

        • — Activation/deactivation of DP slaves

        Yes

        • — Direct data exchange (slave-to-slave communication)

        Yes

        • — DPV1

        Yes

        Address area

         

        • — Inputs, max.

        2 kbyte

        • — Outputs, max.

        2 kbyte

        User data per DP slave

         

        • — User data per DP slave, max.

        244 byte

        • — Inputs, max.

        244 byte

        • — Outputs, max.

        244 byte

        • — Slots, max.

        244

        • — per slot, max.

        128 byte

        DP slave

         

        • ● Number of connections

        32

        • ● GSD file

        http://support.automation.siemens.com/WW/view/en/113652

        • ● Transmission rate, max.

        12 Mbit/s

        • ● automatic baud rate search

        No

        • ● Address area, max.

        32; Virtual slots

        • ● User data per address area, max.

        32 byte

        • — of which consistent, max.

        32 byte

        Services

         

        • — PG/OP communication

        Yes; with interface active

        • — S7 routing

        Yes; with interface active

        • — Global data communication

        No

        • — S7 basic communication

        No

        • — S7 communication

        Yes

        • — S7 communication, as client

        Yes

        • — S7 communication, as server

        Yes

        • — Direct data exchange (slave-to-slave communication)

        No

        • — DPV1

        No

        Transfer memory

         

        • — Inputs

        244 byte

        • — Outputs

        244 byte

        2. Interface

         

        Interface type

        Integrated

        Physics

        RS 485 / PROFIBUS

        Isolated

        Yes

        Power supply to interface (15 to 30 V DC), max.

        150 mA

        Number of connection resources

        32

        Functionality

         

        • ● PROFIBUS DP master

        Yes

        • ● PROFIBUS DP slave

        Yes

        DP master

         

        • ● Number of connections, max.

        32

        • ● Transmission rate, max.

        12 Mbit/s

        • ● Number of DP slaves, max.

        125

        Services

         

        • — PG/OP communication

        Yes

        • — Routing

        Yes; S7 routing

        • — Global data communication

        No

        • — S7 basic communication

        Yes

        • — S7 communication

        Yes

        • — S7 communication, as client

        Yes

        • — S7 communication, as server

        Yes

        • — Equidistance

        Yes

        • — Isochronous mode

        Yes

        • — SYNC/FREEZE

        Yes

        • — Activation/deactivation of DP slaves

        Yes

        • — Direct data exchange (slave-to-slave communication)

        Yes

        • — DPV1

        Yes

        Address area

         

        • — Inputs, max.

        8 kbyte

        • — Outputs, max.

        8 kbyte

        User data per DP slave

         

        • — User data per DP slave, max.

        244 byte

        • — Inputs, max.

        244 byte

        • — Outputs, max.

        244 byte

        • — Slots, max.

        244

        • — per slot, max.

        128 byte

        DP slave

         

        • ● Number of connections

        32

        • ● GSD file

        http://support.automation.siemens.com/WW/view/en/113652

        • ● Transmission rate, max.

        12 Mbit/s

        • ● Address area, max.

        32

        • ● User data per address area, max.

        32 byte

        • — of which consistent, max.

        32 byte

        Services

         

        • — Routing

        Yes; with interface active

        Transfer memory

         

        • — Inputs

        244 byte

        • — Outputs

        244 byte

        3. Interface

         

        Interface type

        Pluggable interface module (IF), technical data as for 2nd interface

        Plug-in interface modules

        IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

        Physics

        RS 485 / PROFIBUS

        Isolated

        Yes

        Power supply to interface (15 to 30 V DC), max.

        150 mA

        automatic detection of transmission rate

        No

        Number of connection resources

        32

        Functionality

         

        • ● MPI

        No

        • ● PROFIBUS DP master

        Yes

        • ● PROFIBUS DP slave

        Yes

        DP master

         

        Services

         

        • — PG/OP communication

        Yes

        • — Routing

        Yes; S7 routing

        • — Global data communication

        No

        • — S7 basic communication

        Yes

        • — S7 communication

        Yes

        • — S7 communication, as client

        Yes

        • — S7 communication, as server

        Yes

        • — Equidistance

        Yes

        • — Isochronous mode

        Yes

        • — SYNC/FREEZE

        Yes

        • — Activation/deactivation of DP slaves

        Yes

        • — Direct data exchange (slave-to-slave communication)

        Yes

        • — DPV0

        Yes

        • — DPV1

        Yes

        Address area

         

        • — Inputs, max.

        8 kbyte

        • — Outputs, max.

        8 kbyte

        User data per DP slave

         

        • — User data per DP slave, max.

        244 byte

        • — Inputs, max.

        244 byte

        • — Outputs, max.

        244 byte

        • — Slots, max.

        244

        • — per slot, max.

        128 byte

        DP slave

         

        • ● Number of connections

        32

        • ● GSD file

        http://support.automation.siemens.com/WW/view/en/113652

        • ● Transmission rate, max.

        12 Mbit/s

        • ● Address area, max.

        32

        • ● User data per address area, max.

        32 byte

        • — of which consistent, max.

        32 byte

        Services

         

        • — PG/OP communication

        Yes

        • — S7 routing

        Yes; with interface active

        • — Global data communication

        No

        • — S7 basic communication

        No

        • — S7 communication

        Yes

        • — S7 communication, as client

        Yes

        • — S7 communication, as server

        Yes

        • — Direct data exchange (slave-to-slave communication)

        No

        • — DPV1

        No

        Transfer memory

         

        • — Inputs

        244 byte

        • — Outputs

        244 byte

        4. Interface

         

        Interface type

        Pluggable interface module (IF), technical data as for 2nd interface

        Plug-in interface modules

        IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

        Open IE communication

         

        • ● ISO-on-TCP (RFC1006)

        Via CP 443-1 and loadable FB

        • — Data length, max.

        1452 bytes via CP 443-1 Adv.

        Isochronous mode

         

        Isochronous operation (application synchronized up to terminal)

        Yes; For PROFIBUS only

        Equidistance

        Yes

        Number of DP masters with isochronous mode

        4

        User data per isochronous slave, max.

        244 byte

        shortest clock pulse

        1 ms; 0.5 ms without use of SFC 126, 127

        max. cycle

        32 ms

        Communication functions

         

        PG/OP communication

        Yes

        • ● Number of connectable OPs without message processing

        119

        • ● Number of connectable OPs with message processing

        119; When using Alarm_S/SQ and Alarm_D/DQ

        Data record routing

        Yes

        Global data communication

         

        • ● supported

        Yes

        • ● Number of GD loops, max.

        16

        • ● Number of GD packets, transmitter, max.

        16

        • ● Number of GD packets, receiver, max.

        32

        • ● Size of GD packets, max.

        54 byte

        • ● Size of GD packet (of which consistent), max.

        1 variable

        S7 basic communication

         

        • ● supported

        Yes

        • ● User data per job, max.

        76 byte

        • ● User data per job (of which consistent), max.

        1 variable

        S7 communication

         

        • ● supported

        Yes

        • ● as server

        Yes

        • ● as client

        Yes

        • ● User data per job, max.

        64 kbyte

        • ● User data per job (of which consistent), max.

        462 byte; 1 variable

        S5 compatible communication

         

        • ● supported

        Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

        • ● User data per job, max.

        8 kbyte

        • ● User data per job (of which consistent), max.

        240 byte

        • ● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.

        64/64

        Standard communication (FMS)

         

        • ● supported

        Yes; Via CP and loadable FB

        Web server

         

        • ● supported

        No

        Number of connections

         

        • ● overall

        120

        • ● usable for PG communication

        119

        • — reserved for PG communication

        1

        • — adjustable for PG communication, max.

        0

        • ● usable for OP communication

        119

        • — reserved for OP communication

        1

        • — adjustable for OP communication, max.

        0

        • ● usable for S7 basic communication

        118

        • — reserved for S7 basic communication

        0

        • — adjustable for S7 basic communication, max.

        0

        • ● usable for S7 communication

        118

        • — reserved for S7 communication

        0

        • — adjustable for S7 communication, max.

        0

        • ● usable for routing

        59

        • — reserved for routing

        0

        • — adjustable for routing, max.

        0

        S7 message functions

         

        Number of login stations for message functions, max.

        119; Max. 119 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)

        Symbol-related messages

        Yes

        SCAN procedure

        Yes

        Block related messages

        Yes

        Process diagnostic messages

        Yes

        simultaneously active Alarm-S blocks, max.

        1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks

        Alarm 8-blocks

        Yes

        • ● Number of instances for alarm 8 and S7 communication blocks, max.

        10 000

        • ● preset, max.

        1 200

        Process control messages

        Yes

        Number of archives that can log on simultaneously (SFB 37 AR_SEND)

        64

        Number of messages

         

        • ● overall, max.

        1 024

        • ● in 100 ms grid, max.

        128

        • ● in 500 ms grid, max.

        512

        • ● in 1000 ms grid, max.

        1 024

        Number of additional values

         

        • ● with 100 ms grid, max.

        1

        • ● with 500, 1000 ms grid, max.

        10

        Test commissioning functions

         

        Status block

        Yes; Up to 16 simultaneously

        Single step

        Yes

        Number of breakpoints

        16

        Status/control

         

        • ● Status/control variable

        Yes; Up to 16 variable tables

        • ● Variables

        Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

        • ● Number of variables, max.

        70; Status/control

        Forcing

         

        • ● Forcing

        Yes

        • ● Forcing, variables

        Inputs, outputs, bit memories, peripheral inputs, peripheral outputs

        • ● Number of variables, max.

        512

        Diagnostic buffer

         

        • ● present

        Yes

        • ● Number of entries, max.

        3 200

        • — adjustable

        Yes

        • — preset

        120

        Service data

         

        • ● can be read out

        Yes

        Standards, approvals, certificates

         

        CE mark

        Yes

        EAC (formerly Gost-R)

        Yes

        Ambient conditions

         

        Ambient temperature during operation

         

        • ● min.

        -25 °C; = Tmin

        • ● max.

        70 °C; = Tmax

        Extended ambient conditions

         

        • ● relative to ambient temperature-atmospheric pressure-installation altitude

        Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

        Relative humidity

         

        • — With condensation, tested in accordance with IEC 60068-2-38, max.

        100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

        Resistance

         

        • — against biologically active substances / conformity with EN 60721-3-3

        Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

        • — against chemically active substances / conformity with EN 60721-3-3

        Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

        • — against mechanically active substances / conformity with EN 60721-3-3

        Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

        Configuration

         

        Configuration software

         

        • ● STEP 7

        Yes

        Programming

         

        • ● Command set

        see instruction list

        • ● Nesting levels

        7

        • ● Access to consistent data in process image

        Yes

        • ● System functions (SFC)

        see instruction list

        • ● System function blocks (SFB)

        see instruction list

        Programming language

         

        • — LAD

        Yes

        • — FBD

        Yes

        • — STL

        Yes

        • — SCL

        Yes

        • — CFC

        Yes

        • — GRAPH

        Yes

        • — HiGraph®

        Yes

        Number of simultaneously active SFCs

         

        • — DPSYC_FR

        2; SFC 11; per interface

        • — D_ACT_DP

        8; SFC 12; per interface

        • — RD_REC

        8; SFC 59; per interface

        • — WR_REC

        8; SFC 58; per interface

        • — WR_PARM

        8; SFC 55; per interface

        • — PARM_MOD

        1; SFC 57; per interface

        • — WR_DPARM

        2; SFC 56; per interface

        • — DPNRM_DG

        8; SFC 13; per interface

        • — RDSYSST

        8; SFC 51

        • — DP_TOPOL

        1; SFC 103; per interface

        Number of simultaneously active SFBs

         

        • — RDREC

        8; SFB 52; per interface, but not more than 32 across all external interfaces

        • — WRREC

        8; SFB 53; per interface, but not more than 32 across all external interfaces

        Know-how protection

         

        • ● User program protection/password protection

        Yes

        • ● Block encryption

        Yes; With S7 block Privacy

        Dimensions

         

        Width

        50 mm

        Height

        290 mm

        Depth

        219 mm

        Weights

         

        Weight, approx.

        900 g

         

        全部關(guān)于 SIPLUS CPU 417-4

        產(chǎn)品與解決方案在線目錄與訂購系統(tǒng)技術(shù)信息服務與支持與合作伙伴服務項目


         
      相關(guān)產(chǎn)品


      會員登錄

      ×

      請輸入賬號

      請輸入密碼

      =

      請輸驗證碼

      收藏該商鋪

      X
      該信息已收藏!
      標簽:
      保存成功

      (空格分隔,最多3個,單個標簽最多10個字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時間回復您~
      產(chǎn)品對比 二維碼

      掃一掃訪問手機商鋪

      對比框

      在線留言