SINAMICS G120C compact inverters- 訂貨數(shù)據(jù)
-
- 附件
-
- 產(chǎn)品信息
-
- 組態(tài)工具
跳轉(zhuǎn)到概述 優(yōu)勢 設(shè)計(jì) 集成 組態(tài) 技術(shù)規(guī)范 特性曲線 尺寸圖 更多信息 概述 SINAMICS G120C, frame sizes FSAA to FSF, with Inligent Operator Panel IOP SINAMICS G120C compact inverters offer a well-balanced combination of features to address a wide range of applications. They are compact, rugged devices that are easy to operate and can be optionally equipped with a basic or advanced operator panel. SINAMICS G120C inverters are especially suitable when it comes to meeting the requirements of system integrators, OEMs and distributors regarding high productivity and tailored performance. 
優(yōu)勢- Compact design
- Side-by-side design
- High power density, low envelope dimensions
- Simple installation in the tightest space
- Low space requirement
- Use in small control cabinets, close to the machine
- Optimized parameter set
- Optimized commissioning
- Getting Started document
- BOP?2 or IOP operator panels can be used
- Integrated USB connection
- Simple and fast software parameter assignment
- Simple to use during commissioning and in operation
- Minimized training costs, existing SINAMICS know-how can be used
- High degree of service friendliness, simple maintenance
- Plug-in terminals
- Cloning function using BOP?2, IOP or memory card
- Operating hours counter for "drive on" and "motor on"
- Fast mechanical installation
- Intuitive standard commissioning
- Component of Totally Integrated Automation
- Energy-efficient, sensorless vector control
- Automatic flux reduction with V/f ECO
- Integrated energy saving computer
- Safety Integrated (STO)
- Communications versions with PROFINET / EtherNet/IP, PROFIBUS DP, USS/Modbus RTU
- Coated modules
- Operation up to an ambient temperature of 60 °C (140 °F)

設(shè)計(jì)SINAMICS G120C is a compact converter for control cabinet mounting in IP20 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device. The compact mechanical design and the high power density allow these devices to be installed in machine control enclosures and control cabinets for maximum space utilization. The SINAMICS G120C compact converter can be butt-mounted directly, without derating at temperatures up to 40 °C (104 °F).  SINAMICS G120C, frame size FSAA with BOP-2 SINAMICS G120C can be integrated into the widest range of applications, either using the integrated digital and analog inputs or via the integrated fieldbus interface (available in USS, Modbus RTU, PROFIBUS, PROFINET / EtherNet/IP versions). Especially the product versions with integrated PROFIBUS/PROFINET interface make full integration into the Siemens TIA family possible, therefore allowing the advantages of the seamless TIA product family to be fully utilized. SINAMICS G120C devices are preset in the factory so that they can be immediay connected to PROFIBUS and/or PROFINET fieldbus systems without parameterization. SINAMICS G120C is also equipped with the safety function STO (Safe Torque Off) as standard, which is used to safely stop drives. As a consequence, machine manufacturers can simply comply with current machinery directives with minimum associated costs. SINAMICS G120C can control asynchronous (induction) motors in the power range from 0.37 kW up to 132 kW (0.5 hp to 200 hp). Reliable and efficient motor operation is achieved by using state-of-the-art IGBT technology combined with vector control. The extensive range of functions integrated in the SINAMICS G120C also offers a high degree of protection for the converter and motor.  Line-side components Line reactors Line reactors smooth the current drawn by the converter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the converter. Recommended line-side power components Standard fuses can be used for the SINAMICS G120C. These must be dimensioned to comply with local regulations. In this chapter, you will find recommended components such as fuses and circuit breakers in compliance with IEC and UL regulations. DC link components Braking resistors Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with the SINAMICS G120C. This has an integrated braking chopper (electronic switch). Load-side power components Output reactors Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected. Supplementary system components Inligent Operator Panel IOP Graphics-based, user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G120C. Basic Operator Panel BOP-2 A 2-line display to provide support when commissioning and troubleshooting the drive. The drive can be locally controlled. Memory card The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediay ready for use again. The associated memory card holder is integrated in the inverter. PC inverter connection kit 2 For controlling and commissioning an inverter directly from a PC if the STARTER commissioning tool or SINAMICS Startdrive has been installed on the PC. Spare parts Shield plates A set of shield plates is included in the scope of delivery for the motor and signal cables corresponding to the frame size of the SINAMICS G120C, and can also be ordered as spare parts. Spare parts kit This kit comprises four I/O terminals, one RS485 terminal, two pairs of Control Unit doors (1 × PN and 1 × other communication versions) and one blanking cover. Set of connectors A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the SINAMICS G120C inverter. Roof-mounted fan A roof-mounted fan (at the top of the device) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C. Fan unit A replacement fan (at the rear of the device; heat sink) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C. 
集成 Connection example for SINAMICS G120C  USS/Modbus RTU communication interface  PROFIBUS DP communication interface  PROFINET, EtherNet/IP communication interface 
組態(tài)The following electronic configuring aids and engineering tools are available for SINAMICS G120C compact inverters: Drive Technology Configurator (DT Configurator) within the CA 01 The interactive catalog CA 01 – the offline Industry Mall of Siemens on DVD?ROM – contains over 100 000 products with approximay 5 million possible drive system product variants. The Drive Technology Configurator (DT Configurator) has been developed to facilitate selection of the correct motor and/or inverter from the wide spectrum of drives. It is integrated in Catalog CA 01 as an add-on on DVD?ROM. Online DT Configurator In addition, the DT Configurator can be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Industry Mall at the following address: http://www.siemens。。com/dt-configurator SIZER for Siemens Drives engineering tool The SIZER for Siemens Drives engineering tool makes it easy to engineer the SINAMICS drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER for Siemens Drives is designed to support configuring of the entire drive system. You can find further information on the SIZER for Siemens Drives engineering tool in the chapter Engineering tools. The SIZER for Siemens Drives engineering tool is available free on the Internet at http://www.siemens。。com/sizer STARTER commissioning tool The STARTER commissioning tool allows menu-prompted commissioning, optimization and diagnostics. Apart from the SINAMICS drives, STARTER is also suitable for MICROMASTER 4 devices. You can find further information about the STARTER commissioning tool in the chapter Engineering tools. Additional information about the STARTER commissioning tool is available on the Internet at http://www.siemens。。com/starter SINAMICS Startdrive commissioning tool SINAMICS Startdrive is a tool for configuring, commissioning, and diagnosing the SINAMICS family of drives and is integrated into the TIA Portal. SINAMICS Startdrive can be used to implement drive tasks with the SINAMICS G110M, SINAMICS G120, SINAMICS G120C, SINAMICS G120D and SINAMICS G120P inverter series. The commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives. You can find further information on the SINAMICS Startdrive commissioning tool in the chapter Engineering tools. The SINAMICS Startdrive commissioning tool is available free on the Internet at http://www.siemens。。com/startdrive Drive ES engineering system Drive ES is the engineering system that can be used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. Two software packages are available for SINAMICS – Drive ES Basic and Drive ES PCS. You can find further information about the Drive ES engineering system in the chapter Engineering tools. Additional information about the Drive ES engineering system is available on the Internet at http://www.siemens。。com/drive-es 
技術(shù)規(guī)范Unless explicitly specified otherwise, the following technical specifications are valid for all SINAMICS G120C compact converters. General technical specifications |
---|
Mechanical specifications | Vibratory load | | - Transport acc. to EN 60721?3?2 1)
| Class 1M2 | - Operation acc. to EN 60721?3?3
| Class 3M1 | Shock load | | - Transport acc. to EN 60721?3?2 1)
| Class 1M2 | - Operation acc. to EN 60721?3?3
| Class 3M2 | Degree of protection | IP20/ UL open type | Permissible mounting position | Vertical wall mounting | Ambient conditions | Protection class According to EN 61800?5?1 | Class III (PELV1) | Touch protection According to EN 61800?5?1 | Class I (with protective conductor system) | Humidity, max. | 95 % at 40 °C (104 °F), condensation and icing not permissible | Ambient temperature | | - Storage 1) acc. to EN 60068?2?1
| -40 ... +70 °C (-40 ... +158 °F) | - Transport 1) acc. to EN 60068?2?1
| -40 ... +70 °C (-40 ... +158 °F) | - Operation acc. to EN 60068?2?2
| -10 ... +40 °C (14 ... 104 °F) without derating >40 ... 60 °C (104 ... 140 °F) see derating characteristics | Environmental class in operation | | - Harmful chemical substances
| Class 3C2 to EN 60721?3?3 | - Organic/biological pollutants
| Class 3B1 to EN 60721?3?3 | | 2 acc. to EN 61800 | Standards | Compliance with standards | CE, UL, cUL, C-Tick (RCM) | Fail-safe certification | Function: Safe Torque Off (STO) | | SIL 2 | - According to EN ISO 13849?1
| PL d and Category 3 | CE marking, according to | EMC Directive 2004/108/EC Low-Voltage Directive 2006/95/EC | EMC Directive 2) According to EN 61800?3 | | Interference immunity | The SINAMICS G120C compact inverters are tested according to the interference immunity requirements for environments according to Category C3. | Interference emissions | | - Frame sizes FSAA to FSC
without integrated line filter
| 3) | - Frame sizes FSAA to FSC
with integrated line filter class A
| The inverters comply with the limit values according to Category C3. The inverters comply with the limit values for conducted interference and field-conducted interference emissions according to Category C2. 4) 5) | | Note: The EMC product standard EN 61800-3 does not apply directly to a frequency converter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the converter. The frequency inverters on their own do not generally require identification according to the EMC Directive. | 1) In transport packaging. 2) For further general information, see also chapter SINAMICS G120, section Technical specifications, Compliance with standards. 3) Non-filtered devices are designed for operation in IT systems or in conjunction with an RCD. The customer must provide suitable RI suppression equipment to ensure that these devices comply with the limits defined for Category C3 or C2. 4) Max. permissible motor cable length of 25 m (82 ft) (shielded) as standard - with low-capacitance CY cable for frame sizes FSA and FSB 50 m (164 ft) (shielded), for FSC 100 m (328 ft) (shielded). 5) SINAMICS G120C compact inverters, frame size FSB, with PROFINET interface (Article No.: 6SL3210-1KE21-.AF1) additionally require a line reactor. SINAMICS G120C compact inverter | USS, Modbus RTU version | PROFIBUS DP version | PROFINET, EtherNet/IP version |
---|
| 6SL3210-1KE..-..B1 6SL3210-1KE..-..B2 | 6SL3210-1KE..-..P1 6SL3210-1KE..-..P2 | 6SL3210-1KE..-..F1 6SL3210-1KE..-..F2 |
---|
Integrated bus interface | Fieldbus protocols | - USS
- Modbus RTU
(switchable using a parameter)
| PROFIBUS DP | - ODVA AC/DC drive
- SINAMICS profiles
| Profile | – | - PROFIdrive Profile V4.1
- PROFIsafe
| - PROFIdrive Profile V4.1
- PROFIsafe
- PROFIenergy
| Hardware | Plug-in terminal, insulated, USS: max. 187.5 kBaud Modbus RTU: 19.2 kBaud, Bus terminating resistor that can be switched in | 9-pin SUB-D socket, insulated, max. 12 Mbit/s Slave address can be set using DIP switches | 2 × RJ45, max. 100 Mbit/s (full duplex), device name can be stored on the device | I/O interfaces | Signal cable cross-section | 0.15 ... 1.5 mm2 (28 ... 16 AWG) | Digital inputs – Standard | 6 isolated inputs Optically isolated; Free reference potential (own potential group) NPN/PNP logic can be selected using the wiring | | 11 V | | 5 V | | 15 mA | Digital inputs, fail-safe | 1 When using the standard digital inputs (DI4+DI5) Safety function: Safe Torque Off (STO) | Digital outputs | 1 relay changeover contact 30 V DC, 0.5 A (ohmic load) 1 transistor 30 V DC, 0.5 A (ohmic load) | Analog inputs | 1 analog input Differential input Switchable between voltage (-10 ... +10 V) and current (0/4 ... 20 mA) using a DIP switch 10?bit resolution Can be used as additional digital input Analog inputs are protected in a voltage range of ± 30 V and have a common-mode voltage in the ± 15 V range. | - Switching threshold: 0 → 1
| 4 V | - Switching threshold: 1 → 0
| 1.6 V | Analog outputs | 1 analog output Non-isolated output Switchable between voltage (0 ... 10 V) and current (0/4 ... 20 mA) using a parameter Voltage mode: 10 V, min. burden 10 kΩ Current mode: 20 mA, max. burden 500 Ω The analog outputs have short-circuit protection | PTC/KTY interface | 1 motor temperature sensor input Connectable sensors PTC, KTY and bimetal, Accuracy ±5 °C (41 °F) | Voltage supply for the integrated Control Unit | 24 V DC via the Power Module or by connecting to an external 20.4 ... 28.8 V DC power supply Typical input current: 500 mA at 24 V DC | Tool interfaces | Memory card | Optional SINAMICS SD card | Operator panels | Optional Basic Operator Panel BOP?2 or Inligent Operator Panel IOP | PC interface | USB | SINAMICS G120C compact inverter |
---|
Open-loop/closed-loop control techniques | U/f linear/quadratic/parameterizable | ? | U/f with flux current control (FCC) | ? | U/f ECO; linear/quadratic | ? | Vector control, sensorless | ? | Vector control, with sensor | – | Torque control, sensorless | – | Torque control, with sensor | – | Software functions | Setpoint input | ? | Fixed frequencies | 16, parameterizable | JOG | ? | Digital motorized potentiometer (MOP) | ? | Ramp smoothing | ? | Extended ramp-function generator (with ramp smoothing Off3) | ? | Positioning down ramp | – | Slip compensation | ? | Signal interconnection with BICO technology | ? | Free function blocks (FFB) for logical and arithmetic operations | – | Switchable drive data sets (DDS) | ? (2) | Switchable command data sets (CDS) | ? (2) | Flying restart | ? | Automatic restart after line supply failure or operating fault (AR) | ? | Technology controller (internal PID) | ? | Energy consumption counter | ? | Energy saving computer | ? | Thermal motor protection | ? (I2t, sensor: PTC, KTY and bimetal) | Thermal inverter protection | ? | Motor identification | ? | Motor holding brake | ? | Auto-ramping (Vdcmax controller) | ? | Kinetic buffering (Vdcmin controller) | ? | Braking functions | | | ? | | ? | - Dynamic braking with integrated braking chopper
| ? | General technical specifications of the power electronics |
---|
System operating voltage | 380 ... 480 V 3 AC +10 % -20 % | Grid requirement Short-circuit power RSC | No restriction | Input frequency | 47 ... 63 Hz | Output frequency | | | 0 ... 550 Hz | | 0 ... 240 Hz | Pulse frequency | 4 kHz for higher pulse frequencies up to 16 kHz, see derating data | Power factor λ | 0.7 ... 0.85 | Offset factor cos φ | ≥0.95 | Output voltage, max. as % of input voltage | 95 % | Overload capability | | - Low overload LO
Note: No reduction in base-load current IL for use of overload.
| 1.5 × base-load current IL (i. e. 150 % overload) for 3 s plus 1.1 × base-load current IL (i. e. 110 % overload) for 57 s within a cycle time of 300 s | - High overload HO
Note: No reduction in base-load current IH for use of overload.
| 2 × base-load current IH (i. e. 200 % overload) for 3 s plus 1.5 × base-load current IH (i. e. 150 % overload) for 57 s within a cycle time of 300 s | Electromagnetic compatibility | - Devices without line filter 1)
- Devices with integrated line filter class A according to EN 55011
| Cooling | Air cooling using an integrated fan | Installation altitude | Up to 1000 m (3281 ft) above sea level without derating, > 1000 m (3281 ft) see derating characteristics | Short Circuit Current Rating (SCCR) 2), max. acc. to UL | 100 kA See recommended line-side components – the value depends on the fuses and circuit breakers used | Protection functions | - Undervoltage
- Overvoltage
- Overload
- Ground fault
- Short-circuit
- Stall protection
- Motor blocking protection
- Motor overtemperature
- Converter overtemperature
| 1) Non-filtered devices are designed for operation in IT systems or in conjunction with an RCD. The customer must provide suitable RI suppression equipment to ensure that these devices comply with the limits defined for Category C3 or C2. 2) Applies to industrial control panel installations to NEC article 409 or UL 508A. Line voltage 380 ... 480 V 3 AC | SINAMICS G120C power electronics |
---|
| 6SL3210-1KE11-8..2 | 6SL3210-1KE12-3..2 | 6SL3210-1KE13-2..2 | 6SL3210-1KE14-3..2 |
---|
Output current at 400 V 3 AC | | | | | | | A | 1.8 | 2.3 | 3.2 | 4.3 | | A | 1.7 | 2.2 | 3.1 | 4.1 | | A | 1.3 | 1.7 | 2.2 | 3.1 | | A | 2.6 | 3.4 | 4.4 | 6.2 | Rated power | | | | | | | kW (hp) | 0.55 (0.74) | 0.75 (1.01) | 1.1 (1.48) | 1.5 (2.01) | | kW | 0.37 (0.50) | 0.55 (0.74) | 0.75 (1.01) | 1.1 (1.48) | Rated pulse frequency | kHz | 4 | 4 | 4 | 4 | Efficiency η | % | 97 | 97 | 97 | 97 | Power loss 4) at rated current | kW | 0.034 (0.05) | 0.039 (0.05) | 0.049 (0.007) | 0.062 (0.08) | Cooling air requirement | m3/s (ft3/s) | 0.005 (0.2) | 0.005 (0.2) | 0.005 (0.2) | 0.005 (0.2) | Sound pressure levelLpA (1 m (3.28 ft)) | dB | <49 | <49 | <49 | <49 | Rated input current5) | | | | | | | A | 2.3 | 2.9 | 4.1 | 5.5 | | A | 1.9 | 2.5 | 3.2 | 4.5 | Length of cable to braking resistor, max. | m (ft) | 15 (49.2) | 15 (49.2) | 15 (49.2) | 15 (49.2) | Line supply connection U1/L1, V1/L2, W1/L3 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | Motor connection U2, V2, W2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | Connection for braking resistor R1, R2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | PE connection | | On housing with M4 screw | On housing with M4 screw | On housing with M4 screw | On housing with M4 screw | Motor cable length, max. 6) | | | | | | - Without filter, shielded/unshielded
| m (ft) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | - With integrated filter class A, shielded/unshielded
| m (ft) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | Dimensions | | | | | | | mm (in) | 73 (2.87) | 73 (2.87) | 73 (2.87) | 73 (2.87) | | mm (in) | 181 (7.13) | 181 (7.13) | 181 (7.13) | 181 (7.13) | | | | | | | | mm (in) | 155 (6.1) (PN version: 178 (7.01)) | 155 (6.1) (PN version: 178 (7.01)) | 155 (6.1) (PN version: 178 (7.01)) | 155 (6.1) (PN version: 178 (7.01)) | | mm (in) | 166/177 (PN version: 189 (7.44)/200 (7.87)) | 166/177 (PN version: 189 (7.44)/200 (7.87)) | 166/177 (PN version: 189 (7.44)/200 (7.87)) | 166/177 (PN version: 189 (7.44)/200 (7.87)) | Frame size | | FSAA | FSAA | FSAA | FSAA | Weight, approx. | | | | | | | kg (lb) | 1.1 (2.43) (PN version: 1.2 (2.65)) | 1.1 (2.43) (PN version: 1.2 (2.65)) | 1.1 (2.43) (PN version: 1.2 (2.65)) | 1.1 (2.43) (PN version: 1.2 (2.65)) | - With integrated filter class A
| kg (lb) | 1.3 (2.87) (PN version: 1.4 (3.09)) | 1.3 (2.87) (PN version: 1.4 (3.09)) | 1.3 (2.87) (PN version: 1.4 (3.09)) | 1.3 (2.87) (PN version: 1.4 (3.09)) | 1) The rated output current Irated can be used up to 100 %; however, without overload. 2) The base-load current IL is based on the duty cycle for low overload (LO). 3) The base-load current IH is based on the duty cycle for high overload (HO). 4) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311 5) The rated input currents are valid for an input voltage of 400 V 3 AC and a line impedance corresponding to uK = 1 % (without line reactor). The rated input current based on IL is stamped on the inverter rating plate. In the particular application, the input current depends on the motor load and line impedance. The input current is reduced when using a line reactor. 6) The maximum motor cable lengths are valid for an input voltage of 400 V 3 AC and operation with a 4 kHz pulse frequency. When an inverter with an integrated line filter class A is used to comply with the limits of EN 61800?3 Category C2 for line-conducted interference emissions, the maximum permissible motor cable length is 25 m (82 ft) (shielded). Line voltage 380 ... 480 V 3 AC | SINAMICS G120C power electronics |
---|
| 6SL3210-1KE15-8..2 | 6SL3210-1KE17-5..1 | 6SL3210-1KE18-8..1 | 6SL3210-1KE21-3..1 |
---|
Output current at 400 V 3 AC | | | | | | | A | 5.8 | 7.5 | 9 | 13 | | A | 5.6 | 7.3 | 8.8 | 12.5 | | A | 4.1 | 5.6 | 7.3 | 8.8 | | A | 8.2 | 11.2 | 14.6 | 17.6 | Rated power | | | | | | | kW | 2.2 (2.95) | 3 (4.02) | 4 (5.36) | 5.5 (7.38) | | kW | 1.5 (2.01) | 2.2 (2.95) | 3 (4.02) | 4 (5.36) | Rated pulse frequency | kHz | 4 | 4 | 4 | 4 | Efficiency η | % | 97 | 97 | 97 | 97 | Power loss 4) at rated current | kW | 0.073 | 0.099 | 0.122 | 0.174 | Cooling air requirement | m3/s (ft3/s) | 0.005 (0.2) | 0.005 (0.2) | 0.005 (0.2) | 0.009 (0.32) | Sound pressure levelLpA (1 m (3.28 ft)) | dB | <49 | <52 | <52 | <63 | Rated input current5) | | | | | | | A | 7.4 | 9.5 | 11.4 | 16.5 | | A | 6 | 8.2 | 10.6 | 12.8 | Length of cable to braking resistor, max. | m (ft) | 15 (49.2) | 15 (49.2) | 15 (49.2) | 15 (49.2) | Line supply connection U1/L1, V1/L2, W1/L3 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 4 .. 6 (12 ... 10 AWG) | Motor connection U2, V2, W2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 4 ... 6 (12 ... 10 AWG) | Connection for braking resistor R1, R2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 1 ... 2.5 (18 ... 14 AWG) | 4 ... 6 (12 ... 10 AWG) | PE connection | | On housing with M4 screw | On housing with M4 screw | On housing with M4 screw | On housing with M4 screw | Motor cable length, max. 6) | | | | | | - Without filter, shielded/unshielded
| m (ft) | 50/100 (164/328) | 150/150 (492/492) | 150/150 (492/492) | 150/150 (492/492) | - With integrated filter class A, shielded/unshielded
| m (ft) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | Dimensions | | | | | | | mm (in) | 73 (2.87) | 73 (2.87) | 73 (2.87) | 100 (3.94) | | mm (in) | 181 (7.13) | 196 (7.72) | 196 (7.72) | 196 (7.72) | | | | | | | | mm (in) | 155 (6.1) (PN version: 178 (7.01)) | 203 (7.99) (PN version: 226 (8.90)) | 203 (7.99) (PN version: 226 (8.90)) | 203 (7.99) (PN version: 226 (8.90)) | | mm (in) | 166 (6.54)/177 (6.97) (PN version: 189 (7.44)/200 (7.87)) | 214 (8.43)/125 (4.92)(PN version: 237 (9.33)/248 (9.76)) | 214 (8.43)/125 (4.92)(PN version: 237 (9.33)/248 (9.76)) | 214 (8.43)/125 (4.92)(PN version: 237 (9.33)/248 (9.76)) | Frame size | | FSAA | FSA | FSA | FSB | Weight, approx. | | | | | | | kg (lb) | 1.1 (2.43) (PN version: 1.2 (2.65)) | 1.7 (3.75) | 1.7 (3.75) | 2.3 (5.07) | - With integrated filter class A
| kg (lb) | 1.3 (2.87) (PN version: 1.4 (3.09)) | 1.9 (4.19) | 1.9 (4.19) | 2.5 (5.51) | 1) The rated output current Irated can be used up to 100 %; however, without overload. 2) The base-load current IL is based on the duty cycle for low overload (LO). 3) The base-load current IH is based on the duty cycle for high overload (HO). 4) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311 5) The rated input currents are valid for an input voltage of 400 V 3 AC and a line impedance corresponding to uK = 1 % (without line reactor). The rated input current based on IL is stamped on the inverter rating plate. In the particular application, the input current depends on the motor load and line impedance. The input current is reduced when using a line reactor. 6) The maximum motor cable lengths are valid for an input voltage of 400 V 3 AC and operation with a 4 kHz pulse frequency. When an inverter with an integrated line filter class A is used to comply with the limits of EN 61800?3 Category C2 for line-conducted interference emissions, the maximum permissible motor cable length is 25 m (82 ft) (shielded) as standard - for frame sizes FSA and FSB with low-capacitance CY cable (shielded) it is 50 m (164 ft). Line voltage 380 ... 480 V 3 AC | SINAMICS G120C power electronics |
---|
| 6SL3210-1KE21-7..1 | 6SL3210-1KE22-6..1 | 6SL3210-1KE23-2..1 | 6SL3210-1KE23-8..1 |
---|
Output current at 400 V 3 AC | | | | | | | A | 17 | 26 | 32 | 38 | | A | 16.5 | 25 | 31 | 37 | | A | 12.5 | 16.5 | 25 | 31 | | A | 25 | 33 | 50 | 62 | Rated power | | | | | | | kW | 7.5 (10.1) | 11 (14.8) | 15 (20.1) | 18.5 (24.8) | | kW | 5.5 (7.38) | 7.5 (10.1) | 11 (14.8) | 15 (20.1) | Rated pulse frequency | kHz | 4 | 4 | 4 | 4 | Efficiency η | % | 97 | 97 | 97 | 97 | Power loss 4) at rated current | kW | 0.236 | 0.301 | 0.373 | 0.45 (15.9) | Cooling air requirement | m3/s (ft3/s) | 0.009 (0.32) | 0.018 (0.64) | 0.018 (0.64) | 0.018 (0.64) | Sound pressure levelLpA (1 m (3.28 ft)) | dB | <63 | <66 | <66 | <66 | Rated input current5) | | | | | | | A | 21.5 | 33 | 40.6 | 48.2 | | A | 18.2 | 24.1 | 36.4 | 45.2 | Length of cable to braking resistor, max. | m (ft) | 15 (49.2) | 15 (49.2) | 15 (49.2) | 15 (49.2) | Line supply connection U1/L1, V1/L2, W1/L3 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 4 ... 6 (12 ... 10 AWG) | 6 ... 16 (10 ... 5 AWG) | 10 ... 16 (7 ... 5 AWG) | 10 ... 16 (7 ... 5 AWG) | Motor connection U2, V2, W2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 4 ... 6 (12 ... 10 AWG) | 6 ... 16 (10 ... 5 AWG) | 10 ... 16 (7 ... 5 AWG) | 10 ... 16 (7 ... 5 AWG) | Connection for braking resistor R1, R2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 4 ... 6 (12 ... 10 AWG) | 6 ... 16 (10 ... 5 AWG) | 10 ... 16 (7 ... 5 AWG) | 10 ... 16 (7 ... 5 AWG) | PE connection | | On housing with M4 screw | On housing with M4 screw | On housing with M4 screw | On housing with M4 screw | Motor cable length, max. 6) | | | | | | - Without filter, shielded/unshielded
| m (ft) | 150/150 (492/492) | 150/150 (492/492) | 150/150 (492/492) | 150/150 (492/492) | - With integrated filter class A, shielded/unshielded
| m (ft) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | 50/100 (164/328) | Dimensions | | | | | | | mm (in) | 100 (3.94) | 140 (5.51) | 140 (5.51) | 140 (5.51) | | mm (in) | 196 (7.72) | 295 (11.6) | 295 (11.6) | 295 (11.6) | | | | | | | | mm (in) | 203 (7.99) (PN version: 226 (8.90)) | 203 (7.99) (PN version: 226 (8.90)) | 203 (7.99) (PN version: 226 (8.90)) | 203 (7.99) (PN version: 226 (8.90)) | | mm (in) | 214 (8.43)/125 (4.92)(PN version: 237 (9.33)/248 (9.76)) | 214 (8.43)/125 (4.92)(PN version: 237 (9.33)/248 (9.76)) | 214 (8.43)/125 (4.92)(PN version: 237 (9.33)/248 (9.76)) | 214 (8.43)/125 (4.92)(PN version: 237 (9.33)/248 (9.76)) | Frame size | | FSB | FSC | FSC | FSC | Weight, approx. | | | | | | | kg (lb) | 2.3 (5.07) | 4.4 (9.70) | 4.4 (9.70) | 4.4 (9.70) | - With integrated filter class A
| kg (lb) | 2.5 (5.51) | 4.7 (10.4) | 4.7 (10.4) | 4.7 (10.4) | 1) The rated output current Irated can be used up to 100 %; however, without overload. 2) The base-load current IL is based on the duty cycle for low overload (LO). 3) The base-load current IH is based on the duty cycle for high overload (HO). 4) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311 5) The rated input currents are valid for an input voltage of 400 V 3 AC and a line impedance corresponding to uK = 1 % (without line reactor). The rated input current based on IL is stamped on the inverter rating plate. In the particular application, the input current depends on the motor load and line impedance. The input current is reduced when using a line reactor. 6) The maximum motor cable lengths are valid for an input voltage of 400 V 3 AC and operation with a 4 kHz pulse frequency. When an inverter with an integrated line filter class A is used to comply with the limits of EN 61800-3 Category C2 for line-conducted interference emission, the maximum permissible motor cable length is 25 m (82 ft) (shielded) as standard - with low-capacitance CY cable for frame size FSB 50 m (164 ft) (shielded), for FSC 100 m (328 ft) (shielded). Line voltage 380 ... 480 V 3 AC | SINAMICS G120C power electronics |
---|
| 6SL3210-1KE24-4.F1 | 6SL3210-1KE26-0.F1 | 6SL3210-1KE27-0.F1 | 6SL3210-1KE28-4.F1 |
---|
Output current at 400 V 3 AC | | | | | | | A | ??? | ??? | ??? | ??? | | A | 43 | 58 | 68 | 82.5 | | A | 37 | 43 | 58 | 68 | | A | ??? | ??? | ??? | ??? | Rated power | | | | | | | kW | 22 (29.5) | 30 (40.2) | 37 (49.6) | 45 (60.3) | | kW | 18.5 (24.8) | 22 (29.5) | 30 (40.2) | 37 (49.6) | Rated pulse frequency | kHz | 4 | 4 | 4 | 4 | Efficiency η | % | ??? | ??? | ??? | ??? | Power loss 4) at rated current | kW | ??? | ??? | ??? | ??? | Cooling air requirement | m3/s (ft3/s) | 0.055 (1.94) | 0.055 (1.94) | 0.055 (1.94) | 0.055 (1.94) | Sound pressure level LpA (1 m (3.28 ft)) | dB | ??? | ??? | ??? | ??? | Rated input current 5) | | | | | | | A | 41 | 53 | 64 | 76 | | A | 39 | 44 | 61 | 69 | Length of cable to braking resistor, max. | m (ft) | ??? | ??? | ??? | ??? | Line supply connection U1/L1, V1/L2, W1/L3 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | Motor connection U2, V2, W2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | Connection for braking resistor R1, R2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | 10 ... 35 (20 ... 10 AWG) | PE connection | | ??? | ??? | ??? | ??? | Motor cable length, max. 6) | | | | | | - Without filter, shielded/unshielded
| m (ft) | 200/300 (656/984) | 200/300 (656/984) | 200/300 (656/984) | 200/300 (656/984) | - With integrated filter class A, shielded/unshielded
| m (ft) | ??? | ??? | ??? | ??? | Dimensions | | | | | | | mm (in) | 200 (7.87) | 200 (7.87) | 200 (7.87) | 200 (7.87) | | mm (in) | 472 (18.6) | 472 (18.6) | 472 (18.6) | 472 (18.6) | | | | | | | | mm (in) | 237 (9.33) | 237 (9.33) | 237 (9.33) | 237 (9.33) | | mm (in) | 248/259 | 248/259 | 248/259 | 248/259 | Frame size | | FSD | FSD | FSD | FSD | Weight, approx. | | | | | | | kg (lb) | 17 (37.5) | 17 (37.5) | 18 (39.7) | 18 (39.7) | - With integrated filter class A
| kg (lb) | 19 (41.9) | 19 (41.9) | 20 (44.1) | 20 (44.1) | 1) The rated output current Irated can be used up to 100 %; however, without overload. 2) The base-load current IL is based on the duty cycle for low overload (LO). 3) The base-load current IH is based on the duty cycle for high overload (HO). 4) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311 5) The rated input currents are valid for an input voltage of 400 V 3 AC and a line impedance corresponding to uK = 1 % (without line reactor). The rated input current based on IL is stamped on the inverter rating plate. In the particular application, the input current depends on the motor load and line impedance. The input current is reduced when using a line reactor. 6) The maximum motor cable lengths are valid for an input voltage of 400 V 3 AC and operation with a 4 kHz pulse frequency. When an inverter with an integrated line filter class A is used to comply with the limits of EN 61800-3 Category C2 for line-conducted interference emission, the maximum permissible motor cable length is 25 m (82 ft) (shielded) as standard - with low-capacitance CY cable for frame size FSB 50 m (164 ft) (shielded), for FSC 100 m (328 ft) (shielded). Line voltage 380 ... 480 V 3 AC | SINAMICS G120C power electronics |
---|
| 6SL3210-1KE31-1.F1 | 6SL3210-1KE31-4.F1 | 6SL3210-1KE31-7.F1 | 6SL3210-1KE32-1.F1 | 6SL3210-1KE32-4.F1 |
---|
Output current at 400 V 3 AC | | | | | | | | A | ??? | ??? | ??? | ??? | ??? | | A | 103 | 136 | 164 | 201 | 237 | | A | 83 | 103 | 136 | 164 | 201 | | A | ??? | ??? | ??? | ??? | ??? | Rated power | | | | | | | | kW | 55 (73.8) | 75 (101) | 90 (121) | 110 (148) | 132 (177) | | kW | 45 (60.3) | 55 (73.8) | 75 (101) | 90 (121) | 110 (148) | Rated pulse frequency | kHz | 4 | 4 | 4 | 4 | 4 | Efficiency η | % | ??? | ??? | ??? | ??? | ??? | Power loss 4) at rated current | kW | ??? | ??? | ??? | ??? | ??? | Cooling air requirement | m3/s (ft3/s) | 0.083 (2.93) | 0.153 (5.40) | 0.153 (5.40) | 0.153 (5.40) | 0.153 (5.40) | Sound pressure levelLpA (1 m (3.28 ft)) | dB | ??? | ??? | ??? | ??? | ??? | Rated input current5) | | | | | | | | A | 96 | 134 | 156 | 187 | 221 | | A | 85 | 112 | 144 | 169 | 207 | Length of cable to braking resistor, max. | m (ft) | ??? | ??? | ??? | ??? | ??? | Line supply connection U1/L1, V1/L2, W1/L3 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 25 ... 70 (6 ... 3/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | Motor connection U2, V2, W2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 25 ... 70 (6 ... 3/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | Connection for braking resistor R1, R2 | | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | Plug-in screw terminals | | mm2 | 25 ... 70 (6 ... 3/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | 35 ... 2×120 (1 ... 2×4/0 AWG) | PE connection | | ??? | ??? | ??? | ??? | ??? | Motor cable length, max. 6) | | | | | | | - Without filter, shielded/unshielded
| m (ft) | 200/300 (656/984) | 300/450 (984/1476) | 300/450 (984/1476) | 300/450 (984/1476) | 300/450 (984/1476) | - With integrated filter class A, shielded/unshielded
| m (ft) | ??? | ??? | ??? | ??? | ??? | Dimensions | | | | | | | | mm (in) | 275 (10.8) | 305 (12.01) | 305 (12.01) | 305 (12.01) | 305 (12.01) | | mm (in) | 551 (21.7) | 708 (27.9) | 708 (27.9) | 708 (27.9) | 708 (27.9) | | | | | | | | | mm (in) | 237 (9.33) | 357 (14.1) | 357 (14.1) | 357 (14.1) | 357 (14.1) | | mm (in) | 248/259 | 368/379 | 368/379 | 368/379 | 368/379 | Frame size | | FSE | FSF | FSF | FSF | FSF | Weight, approx. | | | | | | | | kg (lb) | 27 (59.5) | 59 (130) | 59 (130) | 64 (141) | 64 (141) | - With integrated filter class A
| kg (lb) | 29 (63.9) | 62 (137) | 62 (137) | 66 (146) | 66 (146) | 1) The rated output current Irated can be used up to 100 %; however, without overload. 2) The base-load current IL is based on the duty cycle for low overload (LO). 3) The base-load current IH is based on the duty cycle for high overload (HO). 4) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311 5) The rated input currents are valid for an input voltage of 400 V 3 AC and a line impedance corresponding to uK = 1 % (without line reactor). The rated input current based on IL is stamped on the inverter rating plate. In the particular application, the input current depends on the motor load and line impedance. The input current is reduced when using a line reactor. 6) The maximum motor cable lengths are valid for an input voltage of 400 V 3 AC and operation with a 4 kHz pulse frequency. When an inverter with an integrated line filter class A is used to comply with the limits of EN 61800-3 Category C2 for line-conducted interference emission, the maximum permissible motor cable length is 25 m (82 ft) (shielded) as standard - with low-capacitance CY cable for frame size FSB 50 m (164 ft) (shielded), for FSC 100 m (328 ft) (shielded). 
特性曲線Derating data Pulse frequency Rated power based on low overload (LO) | Rated output current in A for a pulse frequency of |
---|
kW | hp | 4 kHz | 6 kHz | 8 kHz | 10 kHz | 12 kHz | 14 kHz | 16 kHz |
---|
0.55 1) | 0.75 | 1.7 | 1.4 | 1.2 | 1 | 0.9 | 0.8 | 0.7 | 0.75 1) | 1 | 2.2 | 1.9 | 1.5 | 1.3 | 1.1 | 1 | 0.9 | 1.1 1) | 1.5 | 3.1 | 2.6 | 2.2 | 1.9 | 1.6 | 1.4 | 1.2 | 1.5 1) | 2 | 4.1 | 3.5 | 2.9 | 2.5 | 2.1 | 1.8 | 1.6 | 2.2 1) | 3 | 5.6 | 4.8 | 3.9 | 3.4 | 2.8 | 2.5 | 2.2 | 3 1) | 4 | 7.3 | 6.2 | 5.1 | 4.4 | 3.7 | 3.3 | 2.9 | 4 1) | 5 | 8.8 | 7.5 | 6.2 | 5.3 | 4.4 | 4 | 3.5 | 5.5 | 7.5 | 12.5 | 10.6 | 8.8 | 7.5 | 6.3 | 5.6 | 5 | 7.5 | 10 | 16.5 | 14 | 11.6 | 9.9 | 8.3 | 7.4 | 6.6 | 11 | 15 | 25 | 21.3 | 17.5 | 15 | 12.5 | 11.3 | 10 | 15 | 20 | 31 | 26.4 | 21.7 | 18.6 | 15.5 | 14 | 12.4 | 18.5 | 25 | 37 | 31.5 | 25.9 | 22.2 | 18.5 | 16.7 | 14.8 | 22 | 30 | 43 | 36.6 | 30.1 | 25.8 | 21.5 | 19.4 | 17.2 | 30 | 40 | 58 | 49.3 | 40.6 | 34.8 | 29 | 26.1 | 23.2 | 37 | 50 | 68 | 57.8 | 47.6 | 40.8 | 34 | 30.6 | 27.2 | 45 | 60 | 82.5 | 70.1 | 57.8 | 49.5 | 41.3 | 37.1 | 33 | 55 | 75 | 103 | 87.6 | 72.1 | – | – | – | – | 75 | 100 | 136 | 115.6 | 95.2 | – | – | – | – | 90 | 125 | 164 | 139.4 | 114.8 | – | – | – | – | 110 | 150 | 140.7 | – | – | – | – | – | – | 132 | 200 | 165.9 | – | – | – | – | – | – | 1) The permissible motor cable length depends on the cable type and the pulse frequency. Ambient temperature  Permissible output current as a function of the ambient temperature, frame sizes FSAA to FSC  Permissible output current as a function of the ambient temperature, frame sizes FSD to FSF Note: The PROFINET version can be butt-mounted at temperatures up to 55 °C (131 °F). At temperatures between 55 °C (131 °F) and 60 °C (140 °F), side-by-side mounting is not possible. Installation altitude Permissible line supplies as a function of the installation altitude - Installation altitude up to 2000 m (6562 ft) above sea level
- Connection to every supply system permitted for the inverter
- Installation altitudes between 2000 m (6562 ft) and 4000 m (13124 ft) above sea level
- Connection to a TN system with grounded neutral point
- TN systems with grounded line conductor are not permitted
- The TN line system with grounded neutral point can also be supplied using an isolation transformer
- The phase-to-phase voltage does not have to be reduced
Note: The connected motors, power elements and components must be considered separay.  Permissible output current as a function of the installation altitude, frame sizes FSAA to FSC  Permissible output current as a function of the installation altitude, frame sizes FSD to FSF Line voltage  Permissible output current as a function of line voltage  Permissible rated power as a function of line voltage 
尺寸圖 SINAMICS G120C, frame size FSAA Mounted with 2 M4 bolts, 2 M4 nuts, 2 M4 washers. When the shield plate is mounted, the drilling pattern is compatible with frame size FSA. Ventilation clearance required at the top: 80 mm (3.15 inches). Ventilation clearance required at the bottom: 100 mm (3.94 inches). Ventilation clearance required at the side: 0 mm (0 inches). When the IOP is inserted, the mounting depth increases by 22 mm (0.87 inches). When the BOP?2 is inserted, the mounting depth increases by 11 mm (0.43 inches). All dimensions in mm (values in brackets are in inches).  SINAMICS G120C, frame size FSA Mounted with 3 M4 bolts, 3 M4 nuts, 3 M4 washers. Ventilation clearance required at the top: 80 mm (3.15 inches). Ventilation clearance required at the bottom: 100 mm (3.94 inches). Ventilation clearance required at the side: 0 mm (0 inches). When the IOP is inserted, the mounting depth increases by 22 mm (0.87 inches). When the BOP?2 is inserted, the mounting depth increases by 11 mm (0.43 inches). All dimensions in mm (values in brackets are in inches).  SINAMICS G120C, frame size FSB Mounted with 4 M4 bolts, 4 M4 nuts, 4 M4 washers. Ventilation clearance required at the top: 80 mm (3.15 inches). Ventilation clearance required at the bottom: 100 mm (3.94 inches). Ventilation clearance required at the side: 0 mm (0 inches). When the IOP is inserted, the mounting depth increases by 22 mm (0.87 inches). When the BOP?2 is inserted, the mounting depth increases by 11 mm (0.43 inches). All dimensions in mm (values in brackets are in inches).  SINAMICS G120C, frame size FSC Mounted with 4 M5 bolts, 4 M5 nuts, 4 M5 washers. Ventilation clearance required at the top: 80 mm (3.15 inches). Ventilation clearance required at the bottom: 100 mm (3.94 inches). Ventilation clearance required at the side: 0 mm (0 inches). When the IOP is inserted, the mounting depth increases by 22 mm (0.87 inches). When the BOP?2 is inserted, the mounting depth increases by 11 mm (0.43 inches). All dimensions in mm (values in brackets are in inches).  SINAMICS G120C frame sizes FSD to FSF SINAMICS G120C | Dimensions in mm (inches) | Drilling dimensions in mm (inches) | Cooling clearance in mm (inches) | Mounting |
---|
Frame size | a (width) | b (height) | c (depth)1) | d | e | f | top | bottom | front | With bolts |
---|
FSD | 200 (7.87) | 472 (18.58) | 237 (9.33) | 170 (6.69) | 430 (16.93) | 15 (0.59) | 300 (11.81) | 350 (13.78) | 100 (3.94) | 4 × M5 | FSE | 275 (10.83) | 551 (21.69) | 237 (9.33) | 230 (9.06) | 509 (20.04) | 11 (0.43) | 300 (11.81) | 350 (13.78) | 100 (3.94) | 4 x M6 | FSF | 305 (12.01) | 708 (27.87) | 357 (14.06) | 270 (10.63) | 680 (26.77) | 13 (0.51) | 300 (11.81) | 350 (13.78) | 100 (3.94) | 4 × M8 |
|