6XV1830-0EH10西門子網(wǎng)絡(luò)總線
參考價(jià): | 面議 |
- 6EP1331-5BA00 產(chǎn)品型號(hào)
- 品牌
- 經(jīng)銷商 廠商性質(zhì)
- 上海市 所在地
訪問(wèn)次數(shù):400更新時(shí)間:2022-04-27 08:02:44
6EP1331-5BA00
SITOP PSU100C 24 V/0.6 A 調(diào)節(jié)電源 輸入:AC 100-230 V (DC 110-300 V) 輸出:DC 24 V/0.6 A
西門子單相24VDC調(diào)節(jié)電源
![]() | 6EP1331-5BA00 SITOP PSU100C 24 V/0.6 A 調(diào)節(jié)電源 輸入:AC 100-230 V (DC 110-300 V) 輸出:DC 24 V/0.6 A |
(SIEMENS)上海贊國(guó)自動(dòng)化科技有限公司(西門子分銷商)
上海贊國(guó)自動(dòng)化科技有限公司
: 顏工[銷售工程師]
():-
傳真():-
:983991865
:
;
地址(Add):上海市松江區(qū)思賢路1855弄91號(hào)
本公司只銷售西門子原裝*,享受西門子免費(fèi)一年保修
西門子單相24VDC調(diào)節(jié)電源
![]() | 6EP1331-5BA10 SITOP PSU100C 24 V/1.3 A 調(diào)節(jié)電源 輸入:AC 120-230 V (DC 110-300 V) 輸出:DC 24 V/1.3 A |
| |||||
![]() | 6EP1332-5BA00 SITOP PSU100C 24 V/2.5 A 調(diào)節(jié)電源 輸入:AC 120-230 V (DC 110-300 V) 輸出:DC 24 V/2.5 A |
| |||||
![]() | 6EP1332-5BA10 SITOP PSU100C 24 V/4 A 調(diào)節(jié)電源 輸入:AC 120-230 V (DC 110-300 V) 輸出:DC 24 V/4 A |
| |||||
![]() | 6EP1332-5BA20 SITOP PSU100C 24 V/3.7 A 調(diào)節(jié)電源 輸入:AC 120-230 V (DC 110-300 V) 輸出:DC 24 V/3.7 A 輸出受限 NEC CLASS 2 |
單相, 24 V DC
- 訂貨數(shù)據(jù)
- 附件
- 產(chǎn)品信息
跳轉(zhuǎn)到
概述
技術(shù)規(guī)范
附件
概述
單相 SITOP compact 是滿足低端性能要求的電源。它們具有極為節(jié)省空間的緊湊設(shè)計(jì),尤其適合控制箱或小型控制柜內(nèi)的分布式應(yīng)用。此系列電源的特點(diǎn)是在整個(gè)負(fù)載范圍具有較低功耗??蛰d運(yùn)行期間的功耗極低,非常適合為頻繁處于待機(jī)模式的機(jī)器設(shè)備供電。SITOP PSU100C 電源具有較寬輸入范圍,適用于交流和直流電網(wǎng);插入式端子促進(jìn)了電纜連接。
要進(jìn)一步提高 24 V 電源的可用性,可將 SITOP compact 電源與 DC UPS、冗余和選擇性模塊結(jié)合使用。
主要產(chǎn)品亮點(diǎn)
- 24 V DC/ 0.6 A、1.3 A、2.5 A 和 4 A
- 24 V DC/3.7 A,用于通過(guò)有限的輸出功率 (100 VA) 為 NEC Class 2 電路供電
- 單相,輸入范圍寬,適用于 85 V 至 264 VAC 或 110 V 至 300 VDC
- 因薄型設(shè)計(jì)而具有較小安裝表面
- 在整個(gè)負(fù)載范圍內(nèi)保持高效率。
- 空載運(yùn)行或待機(jī)期間的電能消耗很低
- 可調(diào)輸出電壓用來(lái)補(bǔ)償電壓降(電流從 1.3 A 起)
- 綠色 LED 指示“24 V 正常”狀態(tài)
- 通過(guò)插入式連接端子進(jìn)行預(yù)制接線和快速電氣連接
- 溫度范圍寬,-20 ~ +70℃
- 通過(guò)全面認(rèn)證,如 UL、ATEX 或 GL
技術(shù)規(guī)范
Article number | 6EP1331-5BA00 | 6EP1331-5BA10 | 6EP1332-5BA00 | 6EP1332-5BA20 | 6EP1332-5BA10 | |
---|---|---|---|---|---|---|
Product | SITOP PSU100C | SITOP PSU100C | SITOP PSU100C | SITOP PSU100C | SITOP PSU100C | |
Power supply, type | 24 V/0.6 A | 24 V/1.3 A | 24 V/2.5 A | 24 V/3.7 A | 24 V/4 A | |
Input |
|
|
|
|
| |
Input | 1-phase AC or DC | 1-phase AC or DC | 1-phase AC or DC | 1-phase AC or DC | 1-phase AC or DC | |
Rated voltage value Vin rated | 100 ... 230 V | 100 ... 230 V | 100 ... 230 V | 100 ... 230 V | 100 ... 230 V | |
Voltage range AC | 85 ... 264 V | 85 ... 264 V | 85 ... 264 V | 85 ... 264 V | 85 ... 264 V | |
Input voltage |
|
|
|
|
| |
| 110 ... 300 V | 110 ... 300 V | 110 ... 300 V | 110 ... 300 V | 110 ... 300 V | |
Wide-range input | Yes | Yes | Yes | Yes | Yes | |
Overvoltage resistance | 2.3 × Vin rated, 1.3 ms | 2.3 × Vin rated, 1.3 ms | 2.3 × Vin rated, 1.3 ms | 2.3 × Vin rated, 1.3 ms | 2.3 × Vin rated, 1.3 ms | |
Mains buffering at Iout rated, min. | 20 ms; at Vin = 230 V | 20 ms; at Vin = 230 V | 20 ms; at Vin = 230 V | 20 ms; at Vin = 230 V | 20 ms; at Vin = 230 V | |
Rated line frequency 1 | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | |
Rated line frequency 2 | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz | |
Rated line range | 47 ... 63 Hz | 47 ... 63 Hz | 47 ... 63 Hz | 47 ... 63 Hz | 47 ... 63 Hz | |
Input current |
|
|
|
|
| |
| 0.28 A | 0.63 A | 1.21 A | 1.88 A | 2.25 A | |
| 0.18 A | 0.31 A | 0.67 A | 0.95 A | 1.15 A | |
Switch-on current limiting (+25 °C), max. | 28 A | 34 A | 31 A | 30 A | 34 A | |
I²t, max. | 0.7 A²·s | 1.2 A²·s | 2.4 A²·s | 3 A²·s | 3 A²·s | |
Built-in incoming fuse | internal | internal | internal | internal | internal | |
Protection in the mains power input (IEC 898) | Recommended miniature circuit breaker: from 6 A characteristic B or from 2 A characteristic C | Recommended miniature circuit breaker: from 6 A characteristic B or from 3 A characteristic C | Recommended miniature circuit breaker: from 10 A characteristic B or from 6 A characteristic C | Recommended miniature circuit breaker: from 10 A characteristic B or from 6 A characteristic C | Recommended miniature circuit breaker: from 10 A characteristic B or from 6 A characteristic C | |
Output |
|
|
|
|
| |
Output | Controlled, isolated DC voltage | Controlled, isolated DC voltage | Controlled, isolated DC voltage | Controlled, isolated DC voltage | Controlled, isolated DC voltage | |
Rated voltage Vout DC | 24 V | 24 V | 24 V | 24 V | 24 V | |
Total tolerance, static ± | 3 % | 3 % | 3 % | 3 % | 3 % | |
Static mains compensation, approx. | 0.1 % | 0.1 % | 0.1 % | 0.1 % | 0.1 % | |
Static load balancing, approx. | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | |
Residual ripple peak-peak, max. | 200 mV | 200 mV | 200 mV | 200 mV | 200 mV | |
Residual ripple peak-peak, typ. | 40 mV | 25 mV | 55 mV | 90 mV | 80 mV | |
Spikes peak-peak, max. (bandwidth: 20 MHz) | 300 mV | 300 mV | 300 mV | 300 mV | 300 mV | |
Spikes peak-peak, typ. (bandwidth: 20 MHz) | 20 mV | 20 mV | 50 mV | 60 mV | 80 mV | |
Adjustment range |
| 22.2 ... 26.4 V | 22.2 ... 26.4 V |
| 22.2 ... 26.4 V | |
Product function Output voltage adjustable | No | Yes | Yes | No | Yes | |
Output voltage setting | - | via potentiometer | via potentiometer | - | via potentiometer | |
Status display | Green LED for output voltage OK | Green LED for output voltage OK | Green LED for output voltage OK | Green LED for output voltage OK | Green LED for output voltage OK | |
On/off behavior | Overshoot of Vout approx. 5 % | Overshoot of Vout approx. 5 % | Overshoot of Vout approx. 1 % | Overshoot of Vout approx. 1 % | Overshoot of Vout approx. 1 % | |
Startup delay, max. | 1 s | 0.6 s | 0.7 s | 1.5 s | 1.5 s | |
Voltage rise, typ. | 25 ms | 90 ms | 100 ms | 500 ms | 400 ms | |
Rated current value Iout rated | 0.6 A | 1.3 A | 2.5 A | 3.7 A | 4 A | |
Current range | 0 ... 0.6 A | 0 ... 1.3 A | 0 ... 2.5 A | 0 ... 3.7 A | 0 ... 4 A | |
|
| +60 ... +70 °C: Derating 0.8%/K; at +70 °C Iout rated 1.2 A | +60 ... +70 °C: Derating 1.6%/K; at +70 °C Iout rated 2.1 A | +50 ... +70 °C: Derating 3.5%/K; at +70 °C Iout rated 1.1 A | +55 ... +70 °C: Derating 3%/K; at +70 °C Iout rated 2.2 A | |
Supplied active power typical | 14 W | 30 W | 60 W | 89 W | 96 W | |
Short-term overload current |
|
|
|
|
| |
| 1 A | 3.1 A |
|
|
| |
Parallel switching for enhanced performance | No | Yes; Start-up with single nominal load only | Yes; Start-up with single nominal load only | No | Yes; Start-up with single nominal load only | |
Numbers of parallel switchable units for enhanced performance |
| 2 | 2 |
| 2 | |
Efficiency |
|
|
|
|
| |
Efficiency at Vout rated, Iout rated, approx. | 82 % | 86 % | 87 % | 87 % | 88 % | |
Power loss at Vout rated, Iout rated, approx. | 2.6 W | 4.5 W | 9 W | 14 W | 13 W | |
Power loss [W] during no-load operation maximum | 0.75 W | 0.75 W | 0.75 W | 0.75 W | 0.75 W | |
Closed-loop control |
|
|
|
|
| |
Dynamic mains compensation (Vin rated ±15 %), max. | 0.1 % | 0.1 % | 0.1 % | 0.1 % | 0.1 % | |
Dynamic load smoothing (Iout: 10/90/10 %), Uout ± typ. | 3 % | 3 % | 3 % | 3 % | 3 % | |
Load step setting time 10 to 90%, typ. | 3 ms | 5 ms | 4 ms | 4 ms | 4 ms | |
Load step setting time 90 to 10%, typ. | 3 ms | 5 ms | 4 ms | 4 ms | 4 ms | |
Protection and monitoring |
|
|
|
|
| |
Output overvoltage protection | Yes, according to EN 60950-1 | Yes, according to EN 60950-1 | Yes, according to EN 60950-1 | Yes, according to EN 60950-1 | Yes, according to EN 60950-1 | |
Current limitation, typ. | 0.7 A | 1.4 A | 3 A | 4 A | 4.8 A | |
Property of the output Short-circuit proof | Yes | Yes | Yes | Yes | Yes | |
Short-circuit protection | Electronic shutdown, automatic restart | Electronic shutdown, automatic restart | Electronic shutdown, automatic restart | Electronic shutdown, automatic restart | Electronic shutdown, automatic restart | |
Overload/short-circuit indicator | - | - | - | - | - | |
Safety |
|
|
|
|
| |
Primary/secondary isolation | Yes | Yes | Yes | Yes | Yes | |
Galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | |
Protection class | Class I | Class I | Class I | Class I | Class I | |
Leakage current |
|
|
|
|
| |
| 3.5 mA | 3.5 mA | 3.5 mA | 3.5 mA | 3.5 mA | |
| 0.4 mA | 0.4 mA | 0.4 mA | 0.4 mA | 0.4 mA | |
CE mark | Yes | Yes | Yes | Yes | Yes | |
UL/cUL (CSA) approval | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310) | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310) | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310) | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310) | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) | |
Explosion protection | ATEX (EX) II 3G Ex nA IIC T4; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | ATEX (EX) II 3G Ex nA IIC T4; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | ATEX (EX) II 3G Ex nA IIC T4; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | ATEX (EX) II 3G Ex nA IIC T4; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | ATEX (EX) II 3G Ex nA IIC T4; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | |
FM approval | - | - | - | - | - | |
CB approval | Yes | Yes | Yes | Yes | Yes | |
Marine approval | GL, ABS | GL, ABS | GL, ABS | GL, ABS | GL, ABS | |
Degree of protection (EN 60529) | IP20 | IP20 | IP20 | IP20 | IP20 | |
EMC |
|
|
|
|
| |
Emitted interference | EN 55022 Class B | EN 55022 Class B | EN 55022 Class B | EN 55022 Class B | EN 55022 Class B | |
Supply harmonics limitation | not applicable | not applicable | not applicable | EN 61000-3-2 | EN 61000-3-2 | |
Noise immunity | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | |
Operating data |
|
|
|
|
| |
Ambient temperature |
|
|
|
|
| |
| -20 ... +70 °C | -20 ... +70 °C | -20 ... +70 °C | -20 ... +70 °C | -20 ... +70 °C | |
| with natural convection | with natural convection | with natural convection | with natural convection | with natural convection | |
| -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | |
| -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | |
Humidity class according to EN 60721 | Climate class 3K3, no condensation | Climate class 3K3, no condensation | Climate class 3K3, no condensation | Climate class 3K3, no condensation | Climate class 3K3, no condensation | |
Mechanics |
|
|
|
|
| |
Connection technology | screw-type terminals | screw-type terminals | screw-type terminals | screw-type terminals | screw-type terminals | |
Connections |
|
|
|
|
| |
| L, N, PE: Removable screw terminal, each for 1 x 0.5 ... 2.5 mm² | L, N, PE: Removable screw terminal, each for 1 x 0.5 ... 2.5 mm² | L, N, PE: Removable screw terminal, each for 1 x 0.5 ... 2.5 mm² | L, N, PE: Removable screw terminal, each for 1 x 0.5 ... 2.5 mm² | L, N, PE: Removable screw terminal, each for 1 x 0.5 ... 2.5 mm² | |
| +: 1 screw terminal for 0.5 ... 2.5 mm²; -: 2 screw terminals for 0.5 ... 2.5 mm² | +: 1 screw terminal for 0.5 ... 2.5 mm²; -: 2 screw terminals for 0.5 ... 2.5 mm² | +: 1 screw terminal for 0.5 ... 2.5 mm²; -: 2 screw terminals for 0.5 ... 2.5 mm² | +: 1 screw terminal for 0.5 ... 2.5 mm²; -: 2 screw terminals for 0.5 ... 2.5 mm² | +: 1 screw terminal for 0.5 ... 2.5 mm²; -: 2 screw terminals for 0.5 ... 2.5 mm² | |
| - | - | - | - | - | |
Width of the enclosure | 22.5 mm | 30 mm | 45 mm | 52.5 mm | 52.5 mm | |
Height of the enclosure | 80 mm | 80 mm | 80 mm | 80 mm | 80 mm | |
Depth of the enclosure | 100 mm | 100 mm | 100 mm | 100 mm | 100 mm | |
Required spacing |
|
|
|
|
| |
| 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | |
| 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | |
| 0 mm | 0 mm | 0 mm | 0 mm | 0 mm | |
| 0 mm | 0 mm | 0 mm | 0 mm | 0 mm | |
Weight, approx. | 0.12 kg | 0.17 kg | 0.22 kg | 0.32 kg | 0.32 kg | |
Product feature of the enclosure housing for side-by-side mounting | Yes | Yes | Yes | Yes | Yes | |
Installation | Snaps onto DIN rail EN 60715 35x7.5/15 | Snaps onto DIN rail EN 60715 35x7.5/15 | Snaps onto DIN rail EN 60715 35x7.5/15 | Snaps onto DIN rail EN 60715 35x7.5/15 | Snaps onto DIN rail EN 60715 35x7.5/15 | |
Electrical accessories | Removable spring-type terminal 6EP1971-5BA00 | Removable spring-type terminal 6EP1971-5BA00 | Removable spring-type terminal 6EP1971-5BA00 | Removable spring-type terminal 6EP1971-5BA00 | Removable spring-type terminal 6EP1971-5BA00 | |
MTBF at 40 °C | 3 910 833 h | 3 838 624 h | 2 881 014 h | 2 776 544 h | 2 726 727 h | |
Other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
附件
SITOP PSE202U 冗余模塊 | 6EP1962-2BA00 |
輸入/輸出:24 V DC/NEC Class 2 | |
SITOP PSE202U 冗余模塊 | 6EP1964-2BA00 |
輸入/輸出:24 V DC/10 A | |
SITOP PSE200U 3 A 選擇性模塊 | |
4 通道選擇性模塊 | |
| 6EP1961-2BA11 |
| 6EP1961-2BA31 |
SITOP PSE200U 10 A 選擇性模塊 | |
4 通道選擇性模塊 | |
| 6EP1961-2BA21 |
| 6EP1961-2BA41 |
SITOP Power PSU100C 附件 | 6EP1971-5BA00 |
可拆卸的彈簧型端子,100 個(gè),適用于 SITOP PSU100C |