參考價(jià): | 面議 |
- skf 產(chǎn)品型號(hào)
- MOTOVARIO 品牌
- 其他 廠商性質(zhì)
- 上海市 所在地
訪問次數(shù):445更新時(shí)間:2015-12-18 14:49:39
skf 530-100160-12 變槳潤滑油泵
ATOS LIDBH1A-4/WP-I 24DC 油壓傳動(dòng)閥
ATOS RZGO-TERS-PS-010/32 53 油壓傳動(dòng)閥
ATOS LIDBH1A-4/WP-I 24DC 油壓傳動(dòng)閥
ATOS AGMZO-A-10/210/6 油壓傳動(dòng)閥
ATOS E-ME-L-01H-LQ82SC 油壓傳動(dòng)閥
ATOS E-ME-AC-05F/RR-420 油壓傳動(dòng)閥
ATOS AGMZO-A-10/210 油壓傳動(dòng)閥
ATOS PM-112 手泵
ATOS RZMO-A-030/315/PE 油壓傳動(dòng)閥
ATOS AGMZO-A-010/350+SP-666 油壓傳動(dòng)閥
ATOS E-ME-AC-05F/RR-420/4 油壓傳動(dòng)閥
ATOS AGMZO-A-10/100/6 油壓傳動(dòng)閥
ATOS E-ME-L-01H 油壓傳動(dòng)閥
ATOS LIMHA-4/350/V-I 24DC 油壓傳動(dòng)閥
ATOS LIMHA-4/350/V-I 24DC DN40 油壓傳動(dòng)閥
ATOS DPHI2631/2-X-24DC 油壓傳動(dòng)閥
ATOS DHA-0613/GK AC220V 油壓傳動(dòng)閥
ATOS LIMHA-4/350/V-IX24DC/X12 油壓傳動(dòng)閥
ATOS AGMZO-A-10/100 油壓傳動(dòng)閥
ATOS DPHI-3714/R 220V 油壓傳動(dòng)閥
ATOS QVKZOR-A-10/90 油壓傳動(dòng)閥
Concrete & Screed Encapsulated Systems
2417510.jpg
LK System Plate 30
Insulation plate of EPS, 30 mm thick with casated pipe holders for LK Universal pipe ? 16 mm.
Pipe spacing ability c/c 80, 160, 240, 320 mm ect.
Short time lasting compression strengths SS 169524, 200kPa (S200)
Long lasting compression strengths 65 kPa (3% compr. in 50 years).
Thermal conductivity capability 0,033 W/m oC.
Height over all incl. pipes 60 mm.
Material consumption:
Approx. 1 package/10 m2
Articles
Accessories & spare parts
Literature
Article no. For pipe dim. Length Width Height Area (m2) Weight (kg) Packaging
241 75 10 16 mm 800 mm 640 mm 30 mm 10.2 12
info.png
Accessories
LK Pipe Holder
Assembly instruction
pdf Embedding in screed with LK System Board 30
2417524.jpg
LK Clip Rail
For LK Universal pipe/LK Floor Heating pipe. Intended to be used where necessary additional insulation is satisfactory. Fix to insulation with LK Pipe Holder Art. no. 241 75 17 or 241 81 08. On concrete floors the clip rail is nailed or screwed to the floor.
Material consumption:
Dim 8 and 12 approx. 1,7 pcs/m2ATOS LIDBH1A-4/WP-I 24DC 油壓傳動(dòng)閥
Dim 16 and 20 i 2 m length, approx. 0,6 pcs/m2
Dim 16 and 20 i 4 m lenght, approx. 0,3 pcs/m2
Articles
Accessories & spare parts
Literature
Article no. For pipe dim. Length Height Weight (kg) Packaging
241 93 65 8 mm 1.2 m 10 mm 0,12
info.png
241 77 48 12 mm 1.2 m 14 mm 0,16
info.png
241 81 24 16 mm 2 m 25 mm 0,5
info.png
241 75 24 16 mm 4 m 25 mm 1,06
info.png
241 81 25 20 mm 2 m 25 mm 0,8
info.png
241 76 99 20 mm 4 m 25 mm 1,56
info.png
Accessories
LK Pipe Holder
Assembly instruction
pdf On load-bearing floors with LK Clip Rail 8
pdf On load-bearing floors with LK Clip Rail 12
pdf Embedding in concrete with LK Clip Rail 16_20
33800.jpg
LK Clip Rail
For LK Under Floor Heating Pipe dim 16/20. Used where there is no need for additional insulation. The rail has an adhesive tape to fix to the insulation. If necessary it can be completed with LK Pipe Holder Nail, Art. no. 241 75 17. The Clip Rails can be snapped together to form longer lengths.
Articles
Article no. Dim. For pipe dim. Length Height Packaging
33800 20 16/20 1 m 27 mm ATOS LIDBH1A-4/WP-I 24DC 油壓傳動(dòng)閥
info.png
2417517.jpg
LK Pipe Holder
Used for fixing pipes at the pipe turns when installing under floor heating using LK Clip Rail or LK System Plate. LK Pipe Holder is also used for fastening the clip rail on to insulation. As standard LK Pipe Holder 65 mm is used. For thin insulation applications the 42 mm version is used.
Material consumption:
Length 65 mm approx. 3 pcs/m2
Length 42 mm approx. 6 pcs/m2
Articles
Inteded for
Article no. For pipe dim. Length Packaging
241 75 17 8-12-16-20 mm 65 mm
info.png
241 81 08 8-12-16 mm 42 mm
info.png
LK Clip Rail
LK System Plate 30
LK Clip Rail
2418146.jpg
2418146.jpg
2418145.jpg
LK Staples
LK Staples are used with LK′s older Staple Gun (Art.no. 241 81 45, see picture) to fix the floor heating pipe to the insulation in pipe bends and in between clip rails. The staples are delivered in a box with 270 pcs or 300 pcs depending on dimension.
The staples are joined together in rows for easy refill of the staple gun. As standard 50 mm is used, and on concrete slabs with thin insulation the short staple is used.
Material consumption:
Length 40 mm, approx. 1 box/75 m2
Length 50 mm, approx. 1 box/100 m2
Articles
Article no. For pipe dim. Length Packaging
241 72 97 8-12-16 40 mm
info.png
241 81 47 8-12-16-20 50 mm ATOS LIDBH1A-4/WP-I 24DC 油壓傳動(dòng)閥
info.png
2419485.jpg
LK Pipe Holding Nail 16-20
LK Pipe Holding Nail 16-20 used for fixing LK Universal Pipe/LK Heating Pipe dim. 16-20 in to insulation.
Articles
Article no. For pipe dim. Length Packaging
241 94 85 16-20 mm 115 mm
info.png
2419486.jpg
LK Pipe Holding Nail 25-63
LK Pipe Holding Nail 25-63 used for fixing LK Universal Pipe/LK Heating Pipe/LK Heating Pipe PiP dim. 25-63 to insulation. Supplied with cable ties.
Articles
Article no. For pipe dim. Length Packaging
241 94 86 25-63 mm 95 mm
info.png
3810513_3810514_3810585.jpg
3810513_3810514_3810585.jpg
3810513.jpg
3810585_60mm-HighResJPG.jpg
LK Nail Clip
LK Nail Clip is intended for clipping pipes to concrete. Pre-drill with an 8 mm drill
Articles
Article no. Type For pipe dim. Length Packaging
381 05 13 Single 25-34 mm 110 mm
info.png
381 05 14 Double 25-34 mm 110 mm
info.png
381 05 85 With cable ties 16-63 mm 65 mm
info.png
2417518.jpg
LK Pipe Clips
Clip-on clips for fixing LK Universal Pipe ? 16 mm on 4 mm steel mesh at edge reinforcements.
Material consumption:
Approx. 2 pcs/m pipe
Articles
Article no. For pipe dim. Packaging
241 75 18 16 mm
info.png
Joist Systems
2418902.jpg
LK HeatFloor 22, Slotted Board
22 mm floor grade chipboard ‘tongue & grooved’ all round. The board has 3 slots centred at 200 mm for LK Universal Pipe ? 16 mm. The board is made in two quality classes, standard V20 and moisture resistant V313. The board shall be supplemented with LK Heat Distribution Plate 16/190, Art. no. 241 80 09.
Building height incl. pipes 22 mm.
Material consumption:
Approx. 1,0 pcs/m2 excl. turning zone surface
Articles
Accessories & spare parts
Literature
Article no. Length Width Height Quality class Weight (kg) Packaging
241 89 02 1800 mm 600 mm 22 mm V20 16
info.png
241 92 71 1800 mm 600 mm 22 mm V313 16
info.png
Accessories
LK HeatFloor 22, Turning Board
LK Turning Board XPE 22
LK Heat Distribution Plate 16/190
Assembly instruction
pdf On floor joists with LK HeatFloor 22
2417818.jpg
LK HeatFloor 22, Turning Board
Floor grade chipboard 22 mm with turning slots on the upper side at c/c 200 mm for LK Universal pipe ? 16 mm. The board is made in two quality classes, standard V20 and moisture resistant V313.
Building height incl. pipes 22 mm.
Turning slots on the upper side.
Can be installed on floor joists and on existing floor.
4 entry/exit slots.
Material consumption:
Approx. 1,4 pcs/m turning zone
Articles
Inteded for
Article no. Length Width Height Quality class Weight (kg) Packaging
241 78 18 595 mm 800 mm 22 mm V20 7,1
info.png
241 81 91 595 mm 800 mm 22 mm V313 7,1
info.png
LK HeatFloor 22, Slotted Board
2418009.jpg
LK Heat Distribution Plate 16/190
LK Heat Distribution Plate 0,45 mm aluminium made for LK Universal pipe ? 16 mm. The plate can be shortened by snapping across 3 pcs break lines..
LK Heat Distribution Plate 16/190 is intended for the LK Floor Heating systems below:
LK HeatFloor 22, Slotted board
LK Cross Battening installations
LK Slotted Board EPS 30/50/70 at pipe spacing c/c 200 mm
LK Slotted Board Silencio 36
Material consumption:
LK HeatFloor 22, Slotted board, approx. 4 pcs/m2
Cross Battening installations, approx. 4 pcs/m2
LK Slotted Board EPS 30/50/70, approx. 4,2 pcs/m2
LK Slotted Board Silencio 36, approx. 4,2 pcs/m2
Articles
Inteded for
Literature
Article no. Length Width Weight (kg) Packaging
241 80 09 1150 mm 190 mm 0,31
info.png
LK Slotted Board EPS 30/50/70
LK HeatFloor 22, Slotted Board
Assembly instruction
pdf On floor joists with cross battening and LK Heat Distributing Plate 16
pdf On floor joists with LK Floor Joist Plate AL
2417549.jpg
LK Floor Joist Plate 16
3 slots centred at 200 mm adapted for LK Under Floor Heating Pipe ? 16 mm. Galvanised heat distribution plate 0,5 mm for installation between floor joists with centre distance of 600 mm between the joists and where a load-bearing floor is to be layed directly on the floor joists.
Material consumption:
Approx. 3,7 pcs/m2
Articles
Literature
Article no. Length Width Weight (kg) Packaging
241 75 49 300 mm 595 mm 0,96
info.png
Assembly instruction
pdf On floor joists with LK Floor Joist Plate 16 (Galvanised steel)
93880.jpg
LK Floor Joist Plate 20
2 slots centred at 300 mm adapted for LK Under Floor Heating Pipe ? 20 mm. Galvanised heat distribution plate 0.5 mm for installation between floor joists with centre distance of 600 mm between the joists and where a load bearing floor is to be layed directly on the floor joists.
Material consumption:
Approx. 3,7 pcs/m2
Articles
Literature
Article no. Length Width Packaging
241 80 90 300 mm 595 mm
info.png
Assembly instruction
pdf On floor joists with LK Floor Joist Plate AL
93808.jpg
LK Floor Joist Plate AL
LK Floor Joist Plate AL with omega shaped groves c/c 200 mm for installation on wooden joists at c/c 400 mm. The aluminium plate is available for both 16 mm floor heating pipes and 20 mm pipes. The plate is made of 0.5 mm aluminium. Three break points.
Articles
Literature
Article no. For pipe dim. Length Width Note Packaging
33509 16 1150 mm 390 mm Joists c/c 400 mm
info.png
33510 16 1150 mm 405 mm Joists c/c 411 mm
info.png
33511 20 1150 mm 390 mm Joists c/c 400 mm
info.png
33512 20 1150 mm 405 mm Joists c/c 411 mm
info.png
Assembly instruction
pdf On floor joists with LK Floor Joist Plate AL
2418089.jpg
LK Heat Distribution Plate 20
For LK Under Floor Heating pipe ? 20 mm. Heat distribution plate of aluminium 0,5 mm for laying between cross battening. The plate can be shortened by snapping across the three break lines. The width of the plate is intended for installation with c/c 300 mm.
Material consumption:
Approx. 2,8 pcs/m2
Articles
Literature
Article no. Length Width Weight (kg) Packaging
241 80 89 1150 mm 280 mm 0,33
info.png
Solid Floor & Floating Systems
2419905.jpg
LK Slotted Board EPS 30/50/70
Insulation board in EPS, with 6 slots for laying pipes with LK Universal Pipe 16. Possible pipe distance is c/c 200 or c/c 300 mm.
Compression strength short time load 200 kPa.
Long-term loading 70 kPa (3% compr. over 50 years).
Thermal conductivity 0,034 W/m oC.
When laying pipes at c/c 200 mm the board should be used with LK Heat Distribution Plate 16/190, L 1150, W 190 mm, Art. no. 241 80 09.
When laying pipes at c/c 300 mm the board should be used with LK Heat Distribution Plate 16/280 L 1150, W 280 mm, Art. no. 241 99 08.
Material consumption:
1,5 pcs/m2 excl. turning zone surface
Articles
Accessories & spare parts
Literature
Article no. Length Width Height Weight (kg) Packaging
241 99 05 1200 mm 600 mm 30 mm 0,7
info.png
241 99 06 1200 mm 600 mm 50 mm 1,2
info.png
241 99 07 1200 mm 600 mm 70 mm 1,6
info.png
Accessories
LK Turning Board EPS 30/50/70
LK Heat Distribution Plate 16/190
LK Heat distribution plate 16/280
LK TB Staple 16
Assembly instruction
pdf On load-bearing floors with LK Slotted Board EPS 30-50-70
2418902.jpg
LK HeatFloor 22, Slotted Board
22 mm floor grade chipboard ‘tongue & grooved’ all round. The board has 3 slots centred at 200 mm for LK Universal Pipe ? 16 mm. The board is made in two quality classes, standard V20 and moisture resistant V313. The board shall be supplemented with LK Heat Distribution Plate 16/190, Art. no. 241 80 09.
Building height incl. pipes 22 mm.
Material consumption:
Approx. 1,0 pcs/m2 excl. turning zone surface
Articles
Accessories & spare parts
Literature
Article no. Length Width Height Quality class Weight (kg) Packaging
241 89 02 1800 mm 600 mm 22 mm V20 16
info.png
241 92 71 1800 mm 600 mm 22 mm V313 16
info.png
Accessories
LK HeatFloor 22, Turning Board
LK Turning Board XPE 22
LK Heat Distribution Plate 16/190
Assembly instruction
pdf On floor joists with LK HeatFloor 22
2419902.jpg
LK Turning Board EPS 30/50/70
Turning board in EPS with pipe turns for 16 mm LK Universal Pipe. The board also has two slots for the feeding pipe.
? Compression strength short time load, 200 kPa.
? Long-term loading 70 kPa (3% compr. over 50 years).
? Thermal conductivity 0,034 W/m oC.
Material consumption:
0,9 pcs/m turning zone
Articles
Inteded for
Accessories & spare parts
Article no. Length Width Height Weight (kg) Packaging
241 99 02 300 mm 1200 mm 30 mm 0,3
info.png
241 99 03 300 mm 1200 mm 50 mm 0,5
info.png
241 99 04 1200 mm 300 mm 70 mm 0,7
info.png
LK Slotted Board EPS 30/50/70
Accessories
LK TB Staple 16
2418009.jpg
LK Heat Distribution Plate 16/190
LK Heat Distribution Plate 0,45 mm aluminium made for LK Universal pipe ? 16 mm. The plate can be shortened by snapping across 3 pcs break lines..
LK Heat Distribution Plate 16/190 is intended for the LK Floor Heating systems below:
LK HeatFloor 22, Slotted board
LK Cross Battening installations
LK Slotted Board EPS 30/50/70 at pipe spacing c/c 200 mm
LK Slotted Board Silencio 36
Material consumption:
LK HeatFloor 22, Slotted board, approx. 4 pcs/m2
Cross Battening installations, approx. 4 pcs/m2
LK Slotted Board EPS 30/50/70, approx. 4,2 pcs/m2
LK Slotted Board Silencio 36, approx. 4,2 pcs/m2
Articles
Inteded for
Literature
Article no. Length Width Weight (kg) Packaging
241 80 09 1150 mm 190 mm 0,31
info.png
LK Slotted Board EPS 30/50/70
LK HeatFloor 22, Slotted Board
Assembly instruction
pdf On floor joists with cross battening and LK Heat Distributing Plate 16
pdf On floor joists with LK Floor Joist Plate AL
2418089.jpg
LK Heat distribution plate 16/280
LK Heat distribution plate in 0.45 mm aluminium intended for LK Universal Pipe dim 16. The plate can be adjusted length-wise with the help of 3 break lines. The heat distribution plate is used with LK Slotted Board EPS 30/50/70 mm when laying c/c 300 mm pipes.
Material consumption:
Approx. 2,8 pcs/m2
Articles
Inteded for
Article no. Length Width Weight (kg) Packaging
241 99 08 1150 mm 280 mm 0,42
info.png
LK Slotted Board EPS 30/50/70
2418215.jpg
LK Slotted Board EPS 16
LK Heating Board made of EPS (polystyrene) 16 mm thick with a full cover aluminium heat distribution sheet. The board has 4 pcs slots centred at 150 mm for LK Floor Heating Pipe ? 12 mm.
Compression strength short time load (ISO 844) 400 kPa.
Long lasting compression strength: 140 kPa (2% compr. in 50 years).
Thermal conductivity 0,034 W/m oC.
Material consumption:
Approx. 1,5 pcs/m2 excl. turning zone surface
Articles
Accessories & spare parts
Literature
Article no. Length Width Height Weight (kg) Packaging
241 82 15 1200 mm 600 mm 16 mm 1,5
info.png
Accessories
LK Turning Board EPS 16
LK Feeding Board EPS 16
Assembly instruction
pdf On load-bearing floors with LK Slotted Board EPS 16
2418216.jpg
LK Turning Board EPS 16
Turning board made of EPS (polystyrene) 16 mm thick to be used with LK Slotted Board EPS 16 and LK Floor Heating pipe 12 mm. The board has two extra slots for feed and return pipes.
Compression strength short time load (ISO 844) 400 kPa.
Long lasting compression strength 140 kPa (2% compr. in 50 years).
Thermal conductivity 0,034 W/m oC.
Material consumption:
Approx. 1,8 pcs/m turning zone
Articles
Inteded for
Article no. Length Width Height Weight (kg) Packaging
241 82 16 300 mm 600 mm 16 mm 0,1
info.png
LK Slotted Board EPS 16
2418217.jpg
LK Feeding Board EPS 16
Feeding board made of EPS 16 mm thick. To be used with LK Slotted board EPS 16. The Feeding board is to be used to feed pipes dim 12 mm to each room/heating zone.
Compression strength short time load (ISO 844) 400 kPa.
Long lasting compression strength 140 kPa (2% compr. in 50 years).
Thermal conductivity 0,034 W/m oC.
Material consumption:
Approx. 1,8 pcs/m2 excl. turning zone surface
Articles
Inteded for
Article no. Length Width Height Weight (kg) Packaging
241 82 17 300 mm 600 mm 16 mm 0,1
info.png
LK Slotted Board EPS 16
243 47 76 LK Sp?rbygel 16.jpg
LK TB Staple 16
LK TB Staple 16 is used to fix the pipe (?16) into tracks on the turning boards and feeding boards of EPS.
Material consumption:
7 pcs/ turning board
Articles
Inteded for
Article no. For pipe dim. Note Color Packaging
243 47 76 16 Delivered in a bag with 100 staples Blue
info.png
LK Slotted Board EPS 30/50/70
LK Turning Board EPS 30/50/70
2418807.jpg
LK Slotted Board Silencio 36
Wood fibreboard 36 mm, with 3 st slots c-c 200 mm suitable for use with LK Universal Pipe 16. The board shall be supplemented with LK Heat Distribution Plate 16/190, Art. no. 241 80 09.
Non stock article.
Material consumption:
1,08 pcs/m2
Articles
Literature
Article no. Length Width Height Packaging
241 88 07 1800 mm 600 mm 36 mm
info.png
Assembly instruction
pdf On load-bearing floors with LK Slotted Board Silencio 36
2418808.jpg
LK Turning Board Silencio 36
Wood fibreboard 36 mm with feeding slots on the upper side for LK Universal Pipe 16.
Non stock article.
Material consumption:
0,54 pcs/m2
Articles
Article no. Length Width Height Packaging
241 88 08 1600 mm 300 mm 36 mm
info.png
2418809.jpg
LK Feeding Board Silencio 36
Wood fibreboard 36 mm with feeding slots on the upper side for LK Universal Pipe 16.
Non stock article.
Material consumption:
Approx. 1,0 pcs/m2 excl. turning zone surface
Articles
Article no. Length Width Height Packaging
241 88 09 1800 mm 600 mm 36 mm
info.png
2417748.jpg
LK Clip Rail
For LK Under Floor Heating Pipe. Used where there is no need for additional insulation. To fix the rail to insulation use LK Pipe Holder Art. no. 241 75 17 or 241 81 08. On pre-insulated concrete slab screw or nail the rail down.
Material consumption:
Approx. 1,7 pcs/m2
Articles
Accessories & spare parts
Literature
Article no. For pipe dim. Length Height Weight (kg) Packaging
241 93 65 8 mm 1.2 m 10 mm 0,12
info.png
241 77 48 12 mm 1.2 m 14 mm 0,16
info.png
Accessories
LK Pipe Holder
Assembly instruction
pdf On load-bearing floors with LK Clip Rail 8
pdf On load-bearing floors with LK Clip Rail 12
2419363.jpg
LK Nail Clip
Intended to fix the pipe in e.g. pipe turns when using LK Clip Rail on wooden subfloors. 40 pcs/bag.
Material consumption:
1 bag/5 m2
Articles
Article no. Dim. Note Packaging
241 93 63 8 mm Nail length 15 mm, Clip height 10 mm
info.png
2417900.jpg
LK Turning Board XPE 22
Turning board of XPE. To be used with LK HeatFloor 22 slotted board and LK Universal Pipe ? 16 mm, for laying on load-bearing floors.
Material consumption:
Approx. 1,4 pcs/m turning zone
Articles
Inteded for
Literature
Article no. Length Width Height Weight (kg) Packaging
241 79 00 300 mm 800 mm 22 mm 0,49
info.png
LK HeatFloor 22, Slotted Board
Assembly instruction
pdf On load-bearing floors with LK HeatFloor 22
2418009.jpg
LK Heat Distribution Plate 12
LK Heat Distribution Plate of 0,45 mm aluminium to match LK Under Floor Heating Pipe ? 12 mm. The plate can be shortened by snapping across the break lines. The width of the plate is intended for installation with c/c 150 mm.
Material consumption:
Approx. 5,8 pcs/m2 with pipe distance c/c 150 mm.
Articles
Article no. Length Width Weight (kg) Packaging
241 86 80 1150 mm 140 mm 0,22
info.png
2418089.jpg
LK Heat Distribution Plate 20
For LK Under Floor Heating pipe ? 20 mm. Heat distribution plate of aluminium 0,5 mm for laying between cross battening. The plate can be shortened by snapping across the three break lines. The width of the plate is intended for installation with c/c 300 mm.
Material consumption:
Approx. 2,8 pcs/m2
Articles
Literature
Article no. Length Width Weight (kg) Packaging
241 80 89 1150 mm 280 mm 0,33
info.png
Article no. Volume Weight (kg) Packaging
33523 10 l 10
info.png
33525.jpg
LK Kiilto Floorfix DF
LK Kiilto Flytfix DF for gluing floor boards and for tiling ceramics. Mix with LK Kiilto Fixbinder and water or only water depending on building or construction requirements, see LK assembly instruction for relevant laying procedures. The product is dust reduced.
Articles
Article no. Weight (kg) Packaging
33525 20
info.png
33522.jpg
LK Kiilto Fixbinder
To be used with Kiilto Flytfix. See assembly instruction for relevant laying procedure.
Material consumption:
Mix 5 litres Kiilto Fixbinder with 20 kg Flytfix.
Articles
Article no. Volume Weight (kg) Packaging
33522 5 l 5
info.png
33521.jpg
LK Kiilto Start Primer
Adhesion primer. See assembly instruction for relevant laying procedure.
Material consumption:
Approx. 1 litre/10 m2
Articles
Article no. Volume Weight (kg) Packaging
33521 3 l 3,2
info.png
33524.jpg
LK Kiilto UFH Leveling Compound DF
Leveling compound (filler) for embedding under floor heating and to form drainage slope. See assembly instruction for relevant laying procedure.
The product is dust reduced.
Material consumption:
1,7 kg/mm (screed thickness)/m2
Articles
Article no. Weight (kg) Packaging
33524 20
info.png
8912.jpg
LK Steel Mesh -2,5
LK Steel Mesh for reinforcement of floors using LK Kiilto UFH Leveling Compound. See assembly instruction for relevant laying procedure.
Dim 1200x800 mm.
Wire thickness 2,5 mm.
Mesh 70x70 mm.
Material consumption:
Approx. 1,3 pcs/m2
Articles
Article no. Weight (kg) Packaging
8912 1,07Manifold RF
2419350.jpg
LK Manifold RF
LK Manifold RF is made of stainless steel, the variants having 2 to 12 floor heating circuits. The manifold is delivered pre-mounted in brackets. The manifold has thermometers on the supply and return, manual air-bleed valves and filling/drain valves.
The upper manifold marked FLOW (supply) is fitted with flow indicators graded from 0,5-5 l/min and adjustment valves for the adjustment of individual circuit flows. The flow indicators are made of temperature and impact resistant plastic. The plastic is resistant to anti-freeze, as well as glycol and ethanol with up to 50% mix.
The lower manifold marked RETURN has hand actuators for shutting off individual circuits. The hand actuators are normally replaced with LK Actuator.
Primary flow and return can be connected from the left or right-hand sides. The manifold is ready to be connected to the left-hand side on delivery. Connection from the right is done by removing the end cap assemblies. Connection dimension 1" female thread.
Marking plates for identifying individual floor heating circuits, assembly instructions and a protective bag used to protect the manifold from e.g. splashes of concrete during the assembly period are enclosed.
The manifold requires additionally:
Two LK Ball Valves (Art. no. 241 75 50) or LK Ball Valve Angle (Art. no. 241 79 58). Where appropriate, the ball valve is replaced by LK OptiFlow EVO II. See product range for LK Adjustment Valves.
LK Connection Coupling for pipe range dim: PE-X/PAL pipe in dim 16 (Art. no. 241 72 98) / PE-X pipe in dim 12x2 (Art. no. 241 94 66 ) / PE-X pipe in dim 20x2 (Art. no. 241 94 68).
Alternatively:
LK Press Connection for pipe dim: PE-X/PAL pipe in dim 16 (Art. no. 187 66 06)/PE-X in dim 20x2 (Art. no. 241 94 70).
LK Connection Couplings for PE-X pipe 8x1, PE-X/PAL pipe 20x2,8 and copper pipe 12x1,0 and 15x1,0 are available as accessories.
Connection dimensions:
Connection feed pipe, 1" female
Connection under floor heating pipe, ?" male Eurocone
Dimensions:
The dimensions of the manifold are listed in the table below. Center dimension pipe connections is 50 mm with 25 mm displacement between flow and return. Additional length for accessories are stated below.
LK Ball Valve Straight: 65 mm
LK Ball Valve Angle: 70 mm
LK By-Pass RF: 15 mm
LK By-Pass Delta P RF: 155 mm
LK OptiFlow EVO II incl joint nipple straight: 123 mm
LK OptiFlow EVO II incl joint nipple elbow: 93 mm
Articles
Accessories & spare parts
Literature
Article no. Length Height Depth No. of circuits Weight (kg) Packaging
241 93 50 220 mm 355 mm 90 mm 2 2,2
info.png
241 93 51 270 mm 355 mm 90 mm 3 2,4
info.png
241 93 52 320 mm 355 mm 90 mm 4 2,6
info.png
241 93 53 385 mm 355 mm 90 mm 5 2,9
info.png
241 93 54 420 mm 355 mm 90 mm 6 3,0
info.png
241 93 55 470 mm 355 mm 90 mm 7 3,2
info.png
241 93 57 520 mm 355 mm 90 mm 8 3,4
info.png
241 93 58 570 mm 355 mm 90 mm 9 3,65
info.png
241 93 59 620 mm 355 mm 90 mm 10 3,8
info.png
241 93 60 670 mm 355 mm 90 mm 11 4,0
info.png
Accessories
LK Connection Coupling RF
LK Connection Coupling RF 17x2,0
LK Connection Coupling RF CU
LK Adapter
LK PushFit 8, Single female thread
LK PushFit 8, Duo
LK PushFit 8, Quattro
LK Press Connection RF
LK Manifold Screw Plug
LK By-Pass RF
LK By-Pass Delta P RF
LK Automatic Air Vent RF
LK Pressure Gauge RF
LK Connection VKF RF/1-Circuit Valve
Set
LK Ball Valve straight 1"
LK Ball Valve angle 1"
LK OptiFlow EVO II
LK Connection Set straight
LK Connection Set angle
LK Joint Nipple
LK Manifold Cabinet WP RF
LK Shunt Cabinet WP RF
Spare parts
LK Adjustment valve supply, Manifold RF
LK Cap adjustment valve, Manifold RF
LK Glass to flow indicator 0,5-5 l/min, Manifold RF
LK Key set flow indicator, Manifold RF
LK Adapter LK 26, Manifold RF
LK Return valve complete, VKF RF
LK Return valve, VKF RF (bulk packaging)
LK Return valve handle, Manifold RF
LK Marking plate R
LK Thermometer 0-80 oC
LK End reducer, Manifold RF
LK Plug ?"
LK Drain valve, Manifold RF
LK EuroConus nipple, Manifold RF
LK Bracket pair, Manifold RF
LK Air vent ?"
Assembly instruction
pdf LK Manifold RF
2417849.jpg
LK 1-Circuit Valve
Valve kit for single under floor heating loop. Consists of a control valve and an adjustment valve (return) ?" male thread EuroCone for connecting LK Universal/floor heating pipe.
The kit must be supplemented with LK Connection Coupling RF for pipe range dims:
LK PE-X/PAL pipe dim 16 (Art. no. 241 72 98).
LK PE-X pipe dim 12x2, (Art. no. 241 94 66).
LK PE-X pipe dim 20x2, (Art. no. 241 94 68).
Alternatively with LK Press Connection:
PE-X/PAL pipe dim 16 (Art. no. 187 66 06).
PE-X pipe, dim 20x2 (Art. no. 241 94 70).
It is also possible to connect PE-X pipes 8x1 and copper pipe Cu12x1 or Cu15x1.
1-Circuit Valve can be supplemented with LK Room Control for electronic temperature control.
Articles
Accessories & spare parts
Literature
Article no. Dim. Packaging
241 78 49 ?" male/pipe conn. ?" EuroCone
info.png
Accessories
LK Connection VKF RF/1-Circuit Valve
Set
LK PushFit 8, Single female thread
LK PushFit 8, Single male thread
LK PushFit 8, Duo
LK PushFit 8, Quattro
LK PushFit 8 Repair coupling
Assembly instruction
pdf LK 1-Circuit Valve Kit
2419466.jpg
LK Connection Coupling RF
For connection to LK Manifold RF.
For connection of 8 mm floor heating pipes use LK PushFit 8. See product range for LK PushFit 8.
Articles
Inteded for
Accessories & spare parts
Article no. Intended for Dim. Nipple conn. Packaging
241 94 66 PE/PE-X 12x2,0 3/4" EuroCone
info.png
241 72 98 PE/PE-X/PAL AX16 * ?" EuroCone
info.png
241 94 68 PE/PE-X/PAL 20x2,0 3/4" EuroCone
info.png
LK Manifold RF
Accessories
LK Joint Nipple RF straight
2419466.jpg
LK Connection Coupling RF 17x2,0
Connection coupling RF for PE-pipes and multi layer pipes type PE-AL dim 17x2,0.
Articles
Inteded for
Accessories & spare parts
Article no. Intended for Dim. Nipple conn. Packaging
241 94 67 PE/PE-X/AL-PE 17x2,0 ?" EuroCone
info.png
243 47 71 Uponor PePEX 17x2,0 G20 EuroCone
info.png
LK Manifold RF
Accessories
LK Joint Nipple RF straight
1876605_old.jpg
LK Press Connection RF
For connection of LK PE-X and LK PAL Universal pipe dim.16x2,0/2,2 mm and LK PE-X Heating pipe dim 20x2,0 to LK Manifold RF.
Nipple connection ?" EuroCone
Art. no. 187 66 06 has grey plastic ring and Art. no. 241 94 70 red.
Articles
Inteded for
Accessories & spare parts
PressPex_skiss_Pressanslkoppl.jpg
Article no. Dim. Nipple conn. G mm L mm Packaging
187 66 06 AX16 * 3/4" EuroCone 11 53
info.png
241 94 70 20x2,0 3/4" EuroCone 11 53
info.png
LK Manifold RF
Accessories
LK Joint Nipple RF straight
1870667.jpg
LK Manifold Screw Plug
Manifold screw plug with gasket to plug up unused connections on LK Mini Manifold/LK Manifold RF.
Art. no. 241 74 83 for LK Mini Manifold 12-16 and Art. no. 187 06 68 for LK Mini Manifold 20 and LK Manifold RF.
Articles
Inteded for
Article no. Dim. Manifold type Packaging
241 74 83 ?" LK Mini manifold 12-16
info.png
187 06 68 ?" LK Mini manifold 20 & LK VKF RF
info.png
LK Manifold RF
LK Mini Manifold
2419469.jpg
LK By-Pass RF
Complete set for assembly of by-pass with kvs 0,05 on LK Manifold RF. The by-pass extends installed width by 15 mm.
Articles
Inteded for
Literature
Article no. Packaging
241 94 69
info.png
LK Manifold RF
Assembly instruction
pdf LK By-Pass RF
2419140.jpg
LK By-Pass Delta P RF
LK By-pass Delta P RF is a pressure controlled by-pass valve. The by-pass valve is adapted for easy right or left hand connection to LK Manifold RF. The opening pressure can be set between 10-60 kPa. Maximum capacity 800 l/h. The by-pass extends installed width by 155 mm.
Articles
Inteded for
Literature
Article no. Packaging
241 91 40
info.png
LK Manifold RF
Assembly instruction
pdf LK By-Pass Deltap RF
2417299.jpg
LK Automatic Air Vent RF
Intended for LK Manifold RF. Replaces the standard manual air vent. The air vent has both a manual and automatic venting function. The thread connection is fitted with an o-ring seal to the manifold.
Articles
Inteded for
Literature
Article no. Dim. Packaging
241 72 99 ?"
info.png
LK Manifold RF
Assembly instruction
pdf LK Automatic Air Vent RF
2419484.jpg
LK Pressure Gauge RF
Pressure test gauge for LK Manifold RF. Assemble in place of the manifold′s the manual air vent.
Articles
Inteded for
Article no. Dim. Measuring range Packaging
241 94 84 ?" 0-10 bar
info.png
LK Manifold RF
2419090.jpg
LK Connection VKF RF/1-Circuit Valve
Set
LK Connection VKF RF/1-Circuit Valve Set is a complete kit of four adaptors for connecting LK 1-Circuit Valve (Art. no. 241 78 49) to LK Manifold RF.
Articles
Inteded for
Literature
Article no. Packaging
241 90 90
info.png
LK Manifold RF
LK 1-Circuit Valve
Assembly instruction
pdf LK Connection VKF RF/1-Circuit Valve Set
2417475.jpg
LK Mini Manifold
Brass manifold for connection to LK Minishunt M60. The manifolds have integrated lock-shield valves for balancing the flow of the floor heating loops. The manifolds are available for connecting from 2 to 4 under floor heating loops. Delivered incl. angle fittings ?" male thread and necessary connection couplings for LK PE-X pipe dim 12 mm, PE-X and PAL dim 16 mm or PE-X dim 20 mm. Mounted on LK Minishunt M60 the building height will increase by approx 90 mm.
Articles
Inteded for
Accessories & spare parts
Literature
Article no. Dim. pipe Length No. of circuits Weight (kg) Packaging
241 74 75 12 195 mm 2 1,2
info.png
241 74 76 12 230 mm 3 1,6
info.png
241 74 77 12 265 mm 4 1,95
info.png
241 74 78 16 195 mm 2 1,2