国产强伦姧在线观看无码,中文字幕99久久亚洲精品,国产精品乱码在线观看,色桃花亚洲天堂视频久久,日韩精品无码观看视频免费

      北京藍(lán)博遠(yuǎn)揚(yáng)科技發(fā)展有限公司(MOXA代理)

      當(dāng)前位置:北京藍(lán)博遠(yuǎn)揚(yáng)科技發(fā)展有限公司(MOXA代理)>>串口聯(lián)網(wǎng)服務(wù)器>> NPort S9450I串口聯(lián)網(wǎng)服務(wù)器

      NPort S9450I串口聯(lián)網(wǎng)服務(wù)器

      參  考  價(jià):面議
      具體成交價(jià)以合同協(xié)議為準(zhǔn)

      產(chǎn)品型號(hào)

      品牌

      廠商性質(zhì)經(jīng)銷商

      所在地

      更新時(shí)間:2022-03-12 08:03:12瀏覽次數(shù):189次

      聯(lián)系我時(shí),請(qǐng)告知來(lái)自 智能制造網(wǎng)
      PortSummarySerialPorts4RS-232/422/485portsEthernetSwitchPortsNPortS9450Iallcoppermodels:5RJ45copperportsNPortS9450Icopper/fibermodels:3RJ45copperports
       Port Summary
      Serial Ports4 RS-232/422/485 ports
      Ethernet Switch PortsNPort S9450I all copper models: 5 RJ45 copper ports
      NPort S9450I copper/fiber models: 3 RJ45 copper ports, 2 fiber ports
      Magnetic Isolation Protection1.5 kV built in
      Console Ports1 (10-pin RJ45 connector)
      • Physical Characteristics
      HousingMetal
      Weight2.54 kg (5.60 lb)
      Dimensions80 x 160 x 109 mm (3.15 x 6.30 x 4.29 in)
      • Environmental Limits
      Operating Temperature-40 to 85°C (-40 to 185°F)
      Storage Temperature-40 to 85°C (-40 to 185°F)
      Ambient Relative Humidity5 to 95% (non-condensing)
      • Power Requirements
      Input VoltageWV models: 24/48 VDC (18 to 72 VDC)
      HV models: 110/220 VAC/VDC (88 to 300 VDC, 85 to 264 VAC)
      Input Current520 mA @ 24 VDC
      80 mA @ 110 VDC
      • Standards and Certifications
      SafetyUL 508, UL 61010
      EMCEN 61000-6-2/61000-6-4
      EMICISPR 22, FCC Part 15B Class A
      EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
      IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
      IEC 61000-4-5 Surge: Power 6 kV; Signal: 4 kV
      IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
      IEC 61000-4-8
      Hazardous LocationUL/cUL Class I Division 2 Groups A/B/C/D
      • Warranty
      Warranty Period5 years
      DetailsSee /warranty
      • Device Server Specifications
      • Serial Interface
      Number of Ports4
      Serial StandardsRS-232/422/485
      ConnectorDB9 male
      Serial Line Protection2 kV isolation protection
      RS-485 Data Direction ControlADDC® (Automatic Data Direction Control)
      Console PortDedicated RS-232 console port (10-pin RJ45)
      • Serial Communication Parameters
      Data Bits5, 6, 7, 8
      Stop Bits1, 1.5, 2
      ParityNone, Even, Odd, Space, Mark
      Flow ControlRTS/CTS and XON/XOFF
      Baudrate50 bps to 921.6 Kbps
      • Serial Signals
      RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
      RS-422Tx+, Tx-, Rx+, Rx-, GND
      RS-485-4wTx+, Tx-, Rx+, Rx-, GND
      RS-485-2wData+, Data-, GND
      Digital Input2 inputs with the same ground, but electrically isolated from the electronics• +13 to +30 V for state "1"
      • -30 to +3 V for state "0"
      • Max. input current: 8 mA
      • Software
      Configuration OptionsCommand Line Interface (CLI) through Serial/Telnet/SSH, Web Console (HTTP/HTTPS), Windows Utility
      Windows Real COM DriversWindows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
      Fixed TTY DriversSCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
      Linux Real TTY DriversLinux 2.4.x, 2.6.x, 3.x
      Operation ModesReal COM, TCP Server, TCP Client, UDP, RFC2217, Modbus, DNP3, DNP3 Raw Socket
      ManagementSNMP MIB-II, IEC 61850 MMS
      • Reliability
      Alert ToolsBuilt-in buzzer and RTC (real-time clock)
      Automatic Reboot TriggerBuilt-in WDT (watchdog timer)
      • MTBF (mean time between failures)
      Time347,436 hrs
      StandardTelcordia (Bellcore) Standard TR/SR
      • Ethernet Switch Specifications
      • Ethernet Interface
      StandardsIEEE 802.3 for 10BaseT
      IEEE 802.3u for 100BaseT(X) and 100BaseFX
      IEEE 802.3x for Flow Control
      IEEE 802.1D for Spanning Tree Protocol
      IEEE 802.1w for Rapid STP
      IEEE 802.1Q for VLAN Tagging
      IEEE 802.1p for Class of Service
      IEEE 802.1x for Authenti
      Network ProtocolsICMP, IPv4, TCP, UDP, ARP, Telnet, DNS, HTTP, SMTP, SNTP, IGMPv1/v2, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, GMRP, LACP, RMON
      MIBMIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
      Flow ControlIEEE 802.3x flow control, back pressure flow control interface
      • Switch Properties
      Priority Queues4
      Max. Number of Available VLANs64
      VLAN ID RangeVID 1 to 4094
      IGMP Groups256
      CybersecurityReady for NERC CIP compliance system development• Supports IEC 62443 Level 2
      • Supports port access control list: MAC, 802.1x authentication
      • Supports RADIUS, TACACS+
      • Supports Syslog for system/event
      • Optical Fiber Interface

      • Switch Interface
      RJ45 Ports10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
      Alarm Contact2 relay outputs with current carrying capacity of 1A @ 24 VDC

      Available Models

       Model No.Description
      NPort S9450I-WV-T4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 24/48 VDC, -40 to 85°C operating temperature
      NPort S9450I-HV-T4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
      NPort S9450I-2M-SC-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
      NPort S9450I-2M-SC-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
      NPort S9450I-2M-ST-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
      NPort S9450I-2M-ST-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
      NPort S9450I-2S-SC-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
      NPort S9450I-2S-SC-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
      NPort S9450I-2S-ST-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
      NPort S9450I-2S-ST-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature

      NPort 5410/NPort 5430/NPort 5450串口聯(lián)

      特點(diǎn)和優(yōu)點(diǎn)為設(shè)置IP地址提供了簡(jiǎn)單易用的LCM(液晶模塊)界面自適應(yīng)1

      NPort 5110/NPort 5130/NPort 5150串口聯(lián)

      NPort 5110/NPort 5130/NPort 5150串口聯(lián)

      NPort® 5600系列串口聯(lián)網(wǎng)服務(wù)器

      特點(diǎn)和優(yōu)點(diǎn)簡(jiǎn)單易用的LCM(LiquidCrystalModule)顯

      會(huì)員登錄

      ×

      請(qǐng)輸入賬號(hào)

      請(qǐng)輸入密碼

      =

      請(qǐng)輸驗(yàn)證碼

      收藏該商鋪

      X
      該信息已收藏!
      標(biāo)簽:
      保存成功

      (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

      以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。

      溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

      在線留言