addi制造范圍廣泛的壓力校準(zhǔn)設(shè)備,包括數(shù)字壓力計(jì),壓力校準(zhǔn)器,過程校準(zhǔn)器,壓力測(cè)試設(shè)備。.addi公司是一個(gè)過程校準(zhǔn)工具的供應(yīng)商。我們致力于設(shè)計(jì),制造,并提供zui高質(zhì)量的手持測(cè)試工具和便攜式校準(zhǔn)器的校準(zhǔn)過程和行業(yè)。多年來Addi已成功開發(fā)出自動(dòng)壓力校準(zhǔn)器,數(shù)字壓力測(cè)試儀,數(shù)字壓力校驗(yàn)儀,壓力測(cè)試和校準(zhǔn)的泵,和多功能過程校準(zhǔn)器。addi產(chǎn)品目前在60多個(gè)國(guó)家。
Addi 222A
Multifunction Process Calibrator
•采集,模擬和測(cè)量的溫度和電子信號(hào)
Sources and measures mV, mA, ohms, RTDs, thermocouples, frequency, and pulses
源和措施的MV,馬,歐姆,RTDS,熱電偶,頻率,和脈沖
Simulates and measures 13 thermocouples and 11 RTDs to calibrate transmitters
模擬和測(cè)量13熱電偶和11 RTDS校準(zhǔn)發(fā)射機(jī)
Measures and sources pressure using 160 series Inligent Digital Pressure Modules from -15 psi to 10,000 psi (-1 bar to 700 bar)
措施和壓力源采用160系列智能數(shù)字壓力模塊從15磅到10000磅(1至700巴)
24V loop power supply
24V回路電源
Simultaneous dual reading capability
同時(shí)雙閱讀能力
Automatic switch test
自動(dòng)開關(guān)測(cè)試
Supports square root transmitter
支持平方根發(fā)射機(jī)
Pulse frequency output for the calibration of flow totalizer
脈沖頻率輸出的流量積算儀的標(biāo)定
• Easy to use
•容易使用
Smartphone-like menu and interface make the operation simpler and easier
智能手機(jī)一樣的菜單和界面使操作簡(jiǎn)單容易
Ultra-compact, size 3.9” x 7.6” x 2.0” (100mm x 192mm x 52mm), and weight 1.6 lb (0.7 kg)
超緊湊型,尺寸為3.9“×7.6“×2”(100mm××52mm搭建的),體重1.6磅(0.7公斤)
One hand operation
單手操作
• Calibrated cold junction compensation (Patented)
•校準(zhǔn)的冷端補(bǔ)償()
Cold junction equivalent block in the calibrator
在冷端等效塊校準(zhǔn)器
A calibrated PRT element with flexible leads is installed in the equivalent block for thermocouple cold junction compensation
校準(zhǔn)PRT元與軟導(dǎo)線安裝在等效塊熱電偶冷端補(bǔ)償
This PRT element can be pulled out from the calibrator and re-calibrated and corrected at ice point by users
這PRT元素可以從校準(zhǔn)和重新校準(zhǔn)和糾正在冰點(diǎn)由用戶退出
• Built-in temperature readout
•內(nèi)置的溫度讀數(shù)
CVD coefficients of a calibrated PRT can be input into the calibrator for accurate temperature measurement.
一個(gè)校準(zhǔn)PRT CVD系數(shù)可以輸入精確的溫度測(cè)量?jī)x。
• Multi lingual interface
•多語言界面
English, German, French, Italian, Spanish, Portuguese, Simplified Chinese
英語,德語,法語,意大利語,西班牙語,葡萄牙語,中文簡(jiǎn)體
(Traditional Chinese, Japanese and Russian are available per request)
(傳統(tǒng)的中國(guó),日本和俄羅斯是可用的每個(gè)請(qǐng)求)
• Documenting and automated procedure capability
•記錄和自動(dòng)化程序的能力
Manage the information of the device under test.
在測(cè)試管理設(shè)備的信息。
Set up automated calibration procedures, and ADT 221A performs the test, calculates the errors, displays and/or stores the results in the memory, and highlights the out-of-tolerance points.
建立了自動(dòng)校準(zhǔn)程序,和ADT 221A執(zhí)行測(cè)試,計(jì)算錯(cuò)誤,顯示和/或存儲(chǔ)在內(nèi)存中的結(jié)果,和集錦了寬容點(diǎn)。
As-found and As-left functions allow recording and documenting results for quality control.
如發(fā)現(xiàn)和左功能允許記錄和記錄的質(zhì)量控制結(jié)果。
Download tasks and upload the results.
下載和上傳任務(wù)結(jié)果。
Snapshots allow you to capture and save work.
快照允許您捕獲和保存工作。
• Build-in unit conversion tool
•建設(shè)單位轉(zhuǎn)換工具
Build-in converters for pressure units, temperature units, temperature vs. resistance (RTDs), and temperature vs millivolt (thermocouples)
建立在轉(zhuǎn)換器的壓力單位,溫度單位,溫度與電阻(RTDS),和溫度與毫伏(熱電偶)
• Display
•顯示
3.5 inch TFT color screen
3.5寸TFT彩色屏幕
• Rugged
•崎嶇
Rugged design for harsh environments.
惡劣的環(huán)境中,堅(jiān)固的設(shè)計(jì)。
Passed a 1-meter drop test.
通過一個(gè)1米跌落試驗(yàn)。
Three year warranty for the ADT 221A, and one year for the battery pack
對(duì)ADT 221A保修三年,并為電池組的一年
• Misuse protection
•濫用保護(hù)
Up to 30V voltage on any two sockets and up to 1A current on current sockets will not damage the calibrator. The calibrator will return to normal condition as soon as the voltage or current is removed.
高達(dá)30V的電壓在任何兩個(gè)插座和高達(dá)1A的電流對(duì)套接字不會(huì)損壞校準(zhǔn)器。定會(huì)盡快電壓或電流被恢復(fù)到正常狀態(tài)。
• Rechargeable battery
•可充電電池
Rechargeable Li-ion battery for 15 hours uninterrupted use.
可充電鋰離子電池15小時(shí)不間斷地使用。
Battery life will be reduced when 24V is applied.
電池壽命將減少在24V的應(yīng)用。
The rechargeable battery is replaceable.
充電電池是可更換的。
• NIST Traceable Calibration with data
•NIST校準(zhǔn)數(shù)據(jù)
• Electrical Specifications
Measurement Accuracy | |||||
| Range | Resolution | Accuracy | ||
Voltage DC | ±75.0000 mV ±30.0000 V | 1µV 0.1mV | 0.01%RD+0.005%FS 0.01%RD+0.005%FS | ||
Current DC | ±30.0000 mA | 0.1µA | 0.01%RD+0.005%FS | ||
Resistance | Two-wire | 0 to 400.000 Ω | 1mΩ | 0.02%RD+0.005%FS | |
Three-wire | 0 to 400.000 Ω | 1mΩ | 0.02%RD+0.005%FS | ||
Four-wire | 0 to 400.000 Ω | 1mΩ | 0.01%RD+0.005%FS | ||
Two-wire | 0 to 400.000 Ω | 10mΩ | 0.02%RD+0.005%FS | ||
Three-wire | 0 to 400.000 Ω | 10mΩ | 0.02%RD+0.005%FS | ||
Four-wire | 0 to 400.000 Ω | 10mΩ | 0.01%RD+0.005%FS | ||
Frequency | 1 to 50000.0 Hz | 0.1Hz | 0.005%RD+0.002%FS | ||
Pulse | 0 to 999999 | 1 | N/A | ||
Limit Switch | If the switch has detective voltage, its range is +3V to +24V | ||||
Source Accuracy | |||||
Voltage DC | -10.000 to 75.000mV 0 to 12.0000 V | 1μV 0.1mV | 0.02%RD+0.005%FS 0.02%RD+0.005%FS | ||
Current DC | 0 to 22.000 mA | 1µA | 0.02%RD+0.005%FS | ||
Resistance | 1 to 400.00 Ω 1 to 4000.0 Ω | 10mΩ 100mΩ | 0.02%RD+0.005%FS 0.03%RD+0.01%FS | ||
Frequency | 0 to 50000.0 Hz | 0.1Hz | 0.005%RD+0.002%FS | ||
Pulse | 0 to 999999 | 1 | N/A | ||
DC24V | N/A | N/A | 0.5V |