Safety light curtain | ||||||||||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||||||||
Functions | |||
![]() | Restart interlock: | - | ![]() |
![]() | External device monitoring: | - | ![]() |
![]() | Beam coding: | ![]() | ![]() |
![]() | Beam coding (delivery status): | Non-coded | ![]() |
![]() | Muting with: | Flexi Classic | ![]() |
![]() | Extension connection: | ![]() | ![]() |
![]() | Emergency stop / bypass at extension connection: | - | ![]() |
![]() | Bypass (with UE402): | - | ![]() |
![]() | Operating mode switching (with UE402): | - | ![]() |
![]() | PSDI mode with: | UE470 | ![]() |
![]() | Type of blanking: | 1 beam floating blanking, 2 beam floating blanking | ![]() |
![]() | Type of blanking (delivery status): | deactivated | ![]() |
![]() | Reduced resolution: | - | ![]() |
![]() | Configurable scanning range: | ![]() | ![]() |
![]() | Integrated laser alignment aid: | ![]() | ![]() |
![]() | Configuration method: | DIP switch | ![]() |
![]() | Safe device communication via EFI/SDL: | - | ![]() |
![]() | ![]() |
Technical data | |||
![]() | Protective field height: | 900 mm | ![]() |
![]() | Resolution: | 30 mm | ![]() |
![]() | Scanning range Low Range: | 0 m ... 6 m | ![]() |
![]() | Scanning range High Range: | 5 m ... 19 m | ![]() |
![]() | Housing length: | 1,040 mm | ![]() |
![]() | Housing cross-section: | 52 mm x 55.5 mm | ![]() |
![]() | Type: | Type 4 (IEC 61496) | ![]() |
![]() | Safety integrity level: | SIL3 (IEC 61508), SILCL3 (EN 62061) | ![]() |
![]() | Category: | Category 4 (EN ISO 13849) | ![]() |
![]() | Performance level: | PL e (EN ISO 13849) | ![]() |
![]() | PFHd: | 3.2 * 1E-08 | ![]() |
![]() | TM (mission time): | 20 a | ![]() |
![]() | Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | ![]() |
![]() | Maximum power consumption: | 5.7 W | ![]() |
![]() | Wave length: | 950 nm | ![]() |
![]() | Protection class: | III (EN 50178:1998) | ![]() |
![]() | Enclosure rating: | IP 65 | ![]() |
![]() | Ambient operating temperature from ... to: | 0 °C ... 55 °C | ![]() |
![]() | Connection type: | Plug M12 x 5 | ![]() |
![]() | Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | ![]() |
![]() | Oscillation frequency from ... to: | 10 Hz ... 55 Hz | ![]() |
![]() | Shock resistance: | 10 g, 16 ms, IEC 60068-2-29 | ![]() |
![]() | Connection type extension connection: | Socket M12 x 5 | ![]() |
![]() | Cable length extension connection: | 10 m |